Schneider Electric PowerLogic HDPM6000 Series CT Models for High Accuracy and Split Core Variants Installation Guide

June 4, 2024
Schneider Electric

Schneider Electric PowerLogic HDPM6000 Series CT Models for High Accuracy and Split Core Variants

Safety Information

Important information

Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this bulletin or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.

The addition of either symbol to a “Danger” or “Warning” safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

****DANGER

DANGER indicates an hazardous situation which, if not avoided, will result in death or serious injury

** WARNING**


WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
``CAUTION

CAUTION indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.

``NOTICE


NOTICE is used to address practices not related to physical injury.

Please note

Electrical equipment should be installed, operated, serviced and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.

A qualified person is one who has skills and knowledge related to the construction, installation and operation of electrical equipment and has received safety training to recognize and avoid the hazards involved.

PowerLogic HDPM6000 Series CT Models for High Accuracy and Split-Core Variants (20A ­ 4000A)

Safety Precautions

Installation, wiring, testing and service must be performed in accordance with all local and national electrical codes.

****DANGER


HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

  • Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E in the USA or applicable local standards.
  • Th electrical personnel.
  • Turn off all power supplying equipment before working on or inside the equipment.
  • Product may use multiple voltage/power sources. Disconnect all sources of power before servicing.
  • Always use a properly rated voltage sensing device to confirm power is off
  • Do not depend on this product for voltage indication.
  • Current transformer secondaries must be shorted or connected to a burden at all times.
  • Products rated for basic insulation must be installed on insulated conductors.
  • Replace all doors, covers, and protective devices before powering the equipment.
  • Install device is an appropriate electric and fire enclosure per local regulation
  • This product is not intended for life or safety applications. Failure to follow these instructions will result in death or serious injury.

** WARNING**


RISK OF INJURY OR EQUIPMENT DAMAGE Do not apply current transducers to circuits having a phase-to-phase voltage greater than their voltage rating unless adequate additional insulation is applied between the primary conductor and the current transducers.
equipment damage.

Schneider Electric assumes no responsibility for damage of equipment or personal injury caused by products operated on circuits above their published ratings.

Introduction

Schneider Electric PowerLogic High Accuracy and Split-Core Current Transducers (CTs) provide secondary voltage AC proportional to the primary (sensed) current. For use with the HDPM6000 platform only, these CTs provide a means to transform electrical service amperages to a voltage compatible with monitoring equipment.
These CTs range from 20A to 4000A voltage ratings with 0.2% to 1% accuracy.

Ordering Information

Model Number Description Accuracy

SUN2
METSEHDPM20A12H| 20A, High Accuracy Split-Core CT, 12′ lead| 0.2%
METSEHDPM20A30H| 20A, High Accuracy Split-Core CT, 30′ lead| 0.2%
SUN3
METSEHDPM75A12H| 75A, High Accuracy Split-Core CT, 12′ lead| 0.2%
METSEHDPM75A4H| 75A, High Accuracy Split-Core CT, 30′ lead| 0.2%
METSEHDP150A12H| 150A, High Accuracy Split-Core CT, 12′ lead| 0.2%
METSEHDP150A30H| 150A, High Accuracy Split-Core CT, 30′ lead| 0.2%
SUN4
METSEHDP300A12H| 300A, High Accuracy Split-Core CT, 12′ lead| 0.2%
METSEHDPM300A30H| 300A, High Accuracy Split-Core CT, 30′ lead| 0.2%
METSEHDPM400A12H| 400A, High Accuracy Split-Core CT, 12′ lead| 0.2%
METSEHDPM400A30H| 400A, High Accuracy Split-Core CT, 30′ lead| 0.2%
SUS4
METSEHDPM150A12| 150A, Split-Core CT, 12′ lead| 0.5%
METSEHDPM150A30| 150A, Split-Core CT, 30′ lead| 0.5%
METSEHDPM150A60| 150A, Split-Core CT, 60′ lead| 0.5%
METSEHDPM150A5| 150A, Split-Core CT, HDPM6000S, 5″ lead with connector| 0.5%
METSEHDPM150A16| 150A, Split-Core CT, HDPM6000B, 16″ lead| 0.5%
METSEHDPM300A12| 300A, Split-Core CT, 12′ lead| 0.5%
METSEHDPM300A30| 300A, Split-Core CT, 30′ lead| 0.5%
METSEHDPM300A60| 300A, Split-Core CT, 60′ lead| 0.5%
METSEHDPM300A5| 300A, Split-Core CT, HDPM6000S, 5″ lead with connector| 0.5%
METSEHDPM300A16| 300A, Split-Core CT, HDPM6000B 16″ lead| 0.5%
METSEHDPM400A12| 400A, Split-Core CT, 12′ lead| 0.5%
METSEHDPM400A30| 400A, Split-Core CT, 30′ lead| 0.5%
METSEHDPM400A60| 400A, Split-Core CT, 60′ lead| 0.5%
METSEHDPM400A5| 400A, Split-Core CT, HDPM6000S, 5″ lead with connector| 0.5%
METSEHDPM400A16| 400A, Split-Core CT, HDPM6000B 16″ lead| 0.5%
METSEHDPM600A12| 600A, Split-Core CT, 12′ lead| 0.5%
METSEHDPM600A30| 600A, Split-Core CT, 30′ lead| 0.5%
METSEHDPM600A60| 600A, Split-Core CT, 60′ lead| 0.5%
METSEHDP600A5H| 600A, Split-Core CT, HDPM6000S, 5″ lead with connector| 0.5%
METSEHDP600A16H| 600A, Split-Core CT, HDPM6000B 16″ lead| 0.5%
SUSF
METSEHD150A12| 150A, Split-Core CT, 1″x1″, 12′ lead| 1%
METSEHD150A30| 150A, Split-Core CT, 1″x1″, 30′ lead| 1%
METSEHD150A60| 150A, Split-Core CT, 1″x1″, 60′ lead| 1%
METSEHD300A12| 300A, Split-Core CT, 1″x1″, 12′ lead| 1%
METSEHD300A30| 300A, Split-Core CT, 1″x1″, 30′ lead| 1%
METSEHD300A60| 300A, Split-Core CT, 1″x1″, 60′ lead| 1%
METSEHD300A12L| 300A, Split-Core CT, 2″x2″, 12′ lead| 1%
METSEHD300A30L| 300A, Split-Core CT, 2″x2″, 30′ lead| 1%
METSEHD300A60L| 300A, Split-Core CT, 2″x2″, 60′ lead| 1%
METSEHD400A12| 400A, Split-Core CT, 1.25″x1.25″, 12′ lead| 1%
METSEHD400A30| 400A, Split-Core CT, 1.25″x1.25″, 30′ lead| 1%
METSEHD400A60| 400A, Split-Core CT, 1.25″x1.25″, 60′ lead| 1%
METSEHD400A12L| 400A, Split-Core CT, 2.5″x2.5″, 12′ lead| 1%
METSEHD400A30L| 400A, Split-Core CT, 2.5″x2.5″, 30′ lead| 1%
METSEHD400A60L| 400A, Split-Core CT, 2.5″x2.5″, 60′ lead| 1%
METSEHD600A12| 600A, Split-Core CT, 3″x 3″, 12′ lead| 1%
METSEHD600A30| 600A, Split-Core CT, 3″ x 3″, 30′ lead| 1%
METSEHD600A60| 600A, Split-Core CT, 3″ x 3″, 60′ lead| 1%
METSEHD800A12| 800A, Split-Core CT, 4″x 4″, 12′ lead| 1%
METSEHD800A30| 800A, Split-Core CT, 4″ x 4″, 30′ lead| 1%
METSEHD800A60| 800A, Split-Core CT, 4″ x 4″, 60′ lead| 1%
METSEHD1000A12| 1000A, Split-Core CT, 4″x 4″, 12′ lead| 1%
METSEHD1000A30| 1000A, Split-Core CT, 4″ x 4″, 30′ lead| 1%
METSEHD1200A12| 1200A, Split-Core CT, 4″x 6″, 12′ lead| 1%
METSEHD1200A30| 1200A, Split-Core CT, 4″ x 6″, 30′ lead| 1%
METSEHD1600A12| 1600A, Split-Core CT, 4″x 6″, 12′ lead| 1%
METSEHD1600A30| 1600A, Split-Core CT, 4″ x 6″, 30′ lead| 1%
METSEHD1600A12L| 1600A, Split-Core CT, 4.5″x 4.5″, 12′ lead| 1%
METSEHD1600A30L| 1600A, Split-Core CT, 4.5″ x 4.5″, 30′ lead| 1%
METSEHD2000A12| 2000A, Split-Core CT, 4″x 6″, 12′ lead| 1%
METSEHD2000A30| 2000A, Split-Core CT, 4″ x 6″, 30′ lead| 1%
METSEHD2000A12L| 2000A, Split-Core CT, 6″x 3″, 12′ lead| 1%
METSEHD2000A30L| 2000A, Split-Core CT, 6″ x 3″, 30′ lead| 1%
METSEHD3000A12| 3000A, Split-Core CT, 4″x 4″, 12′ lead| 1%
METSEHD3000A30| 3000A, Split-Core CT, 4″ x 4″, 30′ lead| 1%
METSEHD3000A12L| 3000A, Split-Core CT, 4″x 6″, 12′ lead| 1%
METSEHD3000A30L| 3000A, Split-Core CT, 4″ x 6″, 30′ lead| 1%
METSEHD3000A12XL| 3000A, Split-Core CT, 5″x 12″, 12′ lead| 1%
METSEHD3000A30XL| 3000A, Split-Core CT, 5″ x 12″, 30′ lead| 1%
METSEHD4000A12| 4000A, Split-Core CT, 5″x 12″, 12′ lead| 1%
METSEHD4000A30| 4000A, Split-Core CT, 5″ x 12″, 30′ lead| 1%

Specifications

Output at Rated Current 0.25VAC
Accuracy 0.2% (SUN2/SUN3/SUN4), 0.5% (SUS4) and 1% (SUSF)
Operating Temperature Range -40 to 55 °C (-40 to 131 °F)
Storage Temperature Range -50 to +70 °C (-58 to 158 °F)
Frequency Range 50/60 Hz
Leads B/W twisted pair 18 AWG, AWM, UL1015, 600V, 105 °C
Max. Voltage L-N Sensed Conductor 600 VAC
Altitude of Operation 2000 m max.
Humidity Range 0 to 95% non-condensing
Continuous current rating factor 1
Installation Category Cat III, Pollution Degree 2
Agency Approvals UL2808, CE

Dimensions SUN2, SUN3, SUN4 & SUS4

Model|

W
Window

| A Dimension| **B Dimension| C Dimension**
---|---|---|---|---
SUN2| 0.4 in (10.17 mm)| 2.4 in (60.69 mm)| 1.65 in (41.91 mm)| 0.85 to 1.1 in (21.58 to 27.94 mm)
SUN3| 0.7 in (17.80 mm)| 3.0 in (76.19 mm)| 2.4 in (60.96 mm)| 1.1 in (27.94 mm)
SUN4| 1.25 in (31.75 mm)| 3.3 in (83.81 mm)| 3.1 in (78.74 mm)| 1.3 in (31.04 mm)
SUS4| 1.25 in (31.75 mm)| 3.3 in (83.81 mm)| 3.1 in (78.74 mm)| 1.3 in (31.04 mm)

**** SUSF

Busbar and Phase Orientation
  • The white mark ensures orientation every time the top is attached.
  • Typically, the white mark is on the top right side when looking at the product label.
  • Refer to label for correct CT orientation.

Proper Size and Fitting

  • The window of the CT should be big enough to fit the busbar without
    excess space.

  • A split-core CT should not be oversized around the bus/conductor, resulting in an inaccurate/bad reading.

  • The busbar should also be in the center of the CT window to allow the coils to energize evenly.
    Proper Size and Fitting

Installation

Installation must be performed by a qualified electrician. Turn off and lock out power to the primary circuit before installing these CTs. Use a properly rated voltage sensing device to confirm that power is off.

In any application where fault currents can exceed 20 times the rated current of the CT, use wire ties or similar fasteners to secure both sides of the I-bar to the CT housing.

NOTICE


INCORRECT POLARITY
Align CT arrow to point in the direction of the power flow.
Failure to follow this instruction can result in incorrect readings.

Remove the screws (or push-pins) from the CT and take the top off.

  • Slide the body of the CT over the busbar.
  • Refer to label for correct CT orientation.
  • Re-attach the top to the body of the CT, using the white mark to orient how the top will fit.
  • Place the screws/push-pins back to secure the top to the CT.
  • Once the CT is installed onto the busbar, terminate the leads to the metering device prior to turning on the power.

Schneider Electric
12345 SW Leveton Drive
Tualatin, OR 97062 USA
+1-503-598-4564
schneider-electric.com

© 2021 Schneider Electric. All Rights Reserved.
PowerLogic and Schneider Electric are trademarks or registered trademarks of Schneider Electric in France, the USA and other countries. Other companies’ trademarks are the property of their respective owners.

As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this publication.

Z208152-0C 08/2021

Documents / Resources

| Schneider Electric PowerLogic HDPM6000 Series CT Models for High Accuracy and Split Core Variants [pdf] Installation Guide
PowerLogic HDPM6000 Series, CT Models for High Accuracy and Split Core Variants, PowerLogic HDPM6000 Series CT Models for High Accuracy and Split Core Variants
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals