Midea D10-15FL Storage Electric Water Heater Instruction Manual
- June 4, 2024
- Midea
Table of Contents
The diagram above is just for reference. Please take the appearance of the
actual product as the standard.
Midea Storage Electric Water Heater
Instruction Manual
Model: D10-15FL
D15-15FL
Thank you very much for purchasing our water heater. Before installing and operating your water heater, please read this manual carefully and keep it for future reference.
|
---|---
http://www.midea.com/cn/?utm_source=cn.vi.qrcode|
http://www.midea.com/global/products/home_solution/water_heater/instantaneous_water_heater/
General Remark
- The installation and maintenance have to be carried out by qualified professionals or Midea-authorized technicians.
- The manufacturer shall not be held responsible for any damage or malfunction caused by wrong installation or failure to comply with the following instructions included in this pamphlet.
- For more detailed installation and maintenance guidelines, please refer to the below chapters.
CAUTIONS
Before installing this water heater, check and confirm that the earthing on
the supply socket is reliably grounded. Otherwise, the electric water heater
can not be installed and used. Do not use extension boards. Incorrect
installation and use of this electrical water heater may result in serious
injuries and loss of property.
Special Cautions
-
The supply socket must be earthed reliably. The rated current of the socket shall not be lower than 10A. The socket and plug shall be kept dry to prevent electrical leakage. inspect frequently whether the plugs contact well with the socket. Inspect method is as follows: insert the power supply plug into the socket, after using it for half an hour, shut down the unit and pull the plug out, and inspect the plug whether it scalds the hand. If it scalds(over 50℃), please change another well-contacted socket to avoid the plug being damaged, fire, or other personal accidents resulting from bad-contacting.
-
The installation height of the supply socket shall not be lower than 1.8m. The wall in which the electrical water heater is installed shall be able to bear the load more than two times of the heater filled fully with water without distortion and cracks. Otherwise, other strengthening measures shall be adopted.
-
The pressure relief valve attached to the heater must be installed at the cold water inlet of this heater(see Fig.1), and make sure it is not exposed in the foggy. The water ay be outflowed from the pressure relief valve, so the outflow pipe must open wide in the air; The pressure relief valve needs to be checked and cleaned regularly, so as to make sure it will not be blocked.
-
When using the heater for the first time(or the first use after maintenance), the heater can not be switched on until it has been filled fully with water. When filling the water, at least one of the outlet valves at the outlet of the heater must be opened to exhaust the air. This valve can be closed after the heater has been filled fully with water.
-
The water heater is not intended for use by persons(including children)with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instructions concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the heater.
-
During heating, there may be drops of water dripping from the pressure release hole of the pressure relief valve. This is a normal phenomenon. If there is a large amount of water leak, please contact the customer care center for repair. This pressure release hole shall, under no circumstances, be blocked; otherwise, the heater may be damaged, even resulting in accidents.
-
The drainage pipe connected to the pressure release hole must be kept sloping downwards. Since the water temperature inside the heater can reach up to 75℃, the hot water must not be exposed to human bodies when it is initially used. Adjust the water temperature to a suitable temperature to avoid scalding.
-
If the flexible power supply cord is damaged, the special supply cord provided by the manufacturer must be selected and replaced by professional maintenance personnel.
-
If any parts and components of this electrical water heater are damaged please contact the customer
care center for repair. -
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
-
Children should be supervised to ensure that they do not play with the appliance. The water may drip from the discharge pipe of the pressure-relief device and this pipe must be left open to the atmosphere; The pressure-relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked;
-
In order to drain away the water inside the inner container, it can be drained away from the pressure release valve. Twist the threaded screw of the pressure release valve off, and lift the drain handle upwards.(See Fig.1) A discharge pipe connected to the pressure-relief device is to be installed in a continuously downward direction and in a frost-free environment.
PRODUCT INTRODUCTION
2.1 Nomenclature
- is the product code of the storage electric water heater;
- is the capacity (L);
- represents the rated power (*100W);
- represents the pattern code (eg: A, B,C…);
- represents the extension of the pattern (eg: 1,2,3…).
NOTE
This manual is applicable to the storage electric water heaters (D *-***) manufactured by this company.
2.2 Technical Performance Parameters
Model| Volume (L)| Volume (L)| Rated
Voltage (ACV)| Rated
Pressure (MPa)| Max Of Water Temperature ( ℃)| Protection Class| Waterproof
Grade
---|---|---|---|---|---|---|---
D10-15L| 10| 1500| 220-240| 0.75| 75| I| IPX4
D15-15L| 15| 1500| 220-240| 0.75| 75| I| IPX4
2.3 Brief introduction of product structure
2.4 Internal Wire Diagram
UNIT INSTALLATION
3.1 Installation Instruction
-
This electrical water heater shall be installed on a solid wall. If the strength of the wall cannot bear the load equal to two times of the total weight of the heater filled fully with water, it is then necessary to install special support. In the case of a hollow brick wall, ensure to fill it with cement concrete completely.
-
After selecting a proper location, determine the positions of the two install holes used for expansion bolts with a hook (200mm), Make two holes in the wall with the corresponding depth by using a chopping bit with the size matching the expansion bolts attached with the machine, insert the screws, make the hook upwards, tighten the nuts to fix firmly, and then hang the electrical water heater on it (see Fig.2).
-
Install the supply socket in the wall. The requirements for the socket are as follows: 250V/10A, single phase, and three electrodes. It is recommended to place the socket on the right above the heater. The height of the socket to the ground shall not be less than 1.8m (see Fig.3). If there is a fault on the power cable, it should be replaced by the manufacturers, agencies or qualified person who is able to do this so as to ensure the safety.
|
---|---
④ If the bathroom is too small, the heater can be installed at another place. However, in order to reduce the pipeline heat losses, the installation position of the heater shall be closed to the location shall be as near as possible to the heater.
3.2 Pipelines Connection
-
The dimension of each pipe part is G1/2”; The massive pressure of the inlet should use Pa as the unit; The minimum pressure of the inlet should use Pa as the unit.
-
Connection of pressure relief valve with the heater on the inlet of the water heater.
-
In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided with the heater must be added at the end of the threads to ensure leakproof joints (see Fig.4).
-
If the users want to realize a multi-way supply system, refer to the method shown in fig.5 for the connection of the pipelines.
NOTE
Please be sure to use the accessories provided by our company to install this electric water heater. This electric water heater can not be hung on the support until it has been confirmed to be firm and reliable. Otherwise, the electric water heater may drop off from the wall, resulting in damage of the heater, even serious accidents of injury. When determining the locations of the bolt holes, it shall be ensured that there is a clearance not less than 0.2m on the right side of the electric heater, to convenient the maintenance of the heater, if necessary.
METHODS OF USING
- First, open any one of the outlet valves at the outlet of the water heater, then, open the inlet valve. The water heater gets filled with water. When water flows out of the outlet pipe it implies that the heater has been filled fully with water, and the outlet valve can be closed.
NOTE
During normal operation, the inlet valve shall be always kept open.
- Insert the supply plug into the supply socket.
NOTE
That the rated current of the socket should be no lower than 10A.
- The thermostat will automatically control the temperature. When the water temperature inside the heater has reached the set temperature, it will switch off automatically, when the water temperature falls below the set point the heater will be turned on automatically to restore the heating.
MAINTENANCE
-
Check the power supply plug and socket frequently to make sure that they have good, reliable contact and are well grounded without overheating phenomenon.
-
If the heater is not used for a long time, especially in regions with low atmospheric temperature(lower than 0℃), the water inside the heater shall be drained away. This will
prevent damage to the heater due to water freezing in the inner container, (Refer to Cautions in this manual for the method to drain away the water from the inner container). -
In order to ensure that the water heater operates efficiently for a long time, it is recommended to clean the inner container and the deposits on the electrical heating components periodically.
-
It is recommended to examine the magnesium anode protection materials every six months or so. If all the material has been consumed, please replace with the new material.
WARNING
Do cut off the power supply before maintenance, to avoid danger like an
electric shock.
TROUBLESHOOTING
Failures | Reasons | Treatment |
---|---|---|
The heating indicator light is off. | Failures of the temperature controller. |
Contact professional personnel for repair.
No water coming out of the hot water outlet’| 1. The running water supply is
cut off.
2. The hydraulic pressure is too low.
3. The inlet valve of running water is not open.| 1. Wait for restoration of
the running water supply.
2. Use the heater again when the hydraulic pressure is increased.
3. Open the inlet valve of running water.
The water temperature is too high.| Failures of the temperature control
system.| Contact the professional personnel for repair.
Water leak| Seal problem of the joint of each pipe.| Seal up the joints.
NOTE
Parts illustrated in this use and care manual is indicative only, parts
provided with the product may differ from the illustrations. This product is
intended for household use only. Specifications are subject to change without
notice.
The product is subject to change without notice.
Please keep this manual properly.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>