SEALEY MW140i MMA Inverter Welders Instructions
- June 4, 2024
- SEALEY
Table of Contents
MMA INVERTER WELDERS
MODEL NO’S: MW140i , MW160i
Thank you for purchasing a Sealey product. Manufactured to a high standard,
this product will, if used according to these instructions, and properly
maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND
WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE
INSTRUCTIONS SAFE FOR FUTURE USE.
SAFETY
1.1. ELECTRICALSAFETY
WARNING! It is the responsibility of the owner and the operator to read,
understand and comply with the following: You must check all electrical
products, before use, to ensure that they are safe. You must inspect power
cables, plugs, sockets, and any other connectors for wear or damage. You must
ensure that the risk of electric shock is minimized by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should
be incorporated into the main distribution board. We also recommend that a
Residual Current Device (RCD) is used. It is particularly important to use an
RCD with portable products that are plugged into a supply that is not
protected by an RCCB. If in any doubt consult a qualified electrician. You may
obtain a Residual Current Device by contacting your Sealey stockist. You must
also read and understand the following instructions concerning electrical
safety.
1.1.1. The Electricity at Work Act 1989 requires that all portable electrical
appliances if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical
appliances responsible for the safe condition of those appliances and the
safety of the appliance operators. If in any doubt about electrical safety,
contact a qualified electrician.
**** Ensure that the insulation of all cables on the appliance is safe before
connecting it to the power supply. See 1.1.1. and 1.1.2. and use a Portable
Appliance Tester.
230V 1ph
THE INVERTER MUST BE
CONNECTED TO A
32AMP SUPPLY FOR
MAXIMUM OUTPUT
Ensure that cables are always protected against short circuits and
overload.
Regularly inspect power supply cables and plugs for wear or damage and
check all connections to ensure that none is loose.
**Ensure that the voltage marked on the appliance matches the power supply
to be used.
DO NOT pull or carry the appliance by the power cable.
DO NOT pull the plug from the socket by the cable
DO NOT use worn or damaged cables, plugs, or connectors. Have any faulty item
repaired or replaced immediately by a qualified electrician
1.1.3. We recommend a connection to a supply with a type C breaker. If in
doubt you must contact a qualified electrician to ensure that a suitably rated
supply is available.
WARNING! Be very cautious if using a petrol or diesel generator. The
generator must be stable with regard to frequency (H3), voltage, and waveform.
The output must be higher than the power (kVA) of the inverter. The generator
must also be self-regulating. If any A.M. feature is not respected the working
of the regulation card may be affected.
The use of a generator without a regulator may be dangerous and will
invalidate your inverter warranty.
1.2. GENERAL SAFETY
1.2.1. Operator Safety
** Operators must receive adequate training before using the inverter.
Remove ill-fitting clothing, remove ties, watches, rings, and other loose
jewelry and contain long hair.
DO NOT operate the inverter while under the influence of drugs, alcohol, or
intoxicating medication, or if tired.
Stand correctly keep a good footing and balance, ensure that the floor is
not slippery and wear non-slip shoes.
Keep unauthorized persons away from the work area. Any persons working
within the area must wear the same protective items.
Avoid oily greasy clothing. A spark may ignite them.
DO NOT touch the workpiece close to the weld as it will be very hot.
Allow cooling.
DO NOT touch the electrode holder immediately after use. Allow the
electrode holder to cool.
****Wear safety welding gauntlets
1.2.2. Cable Connections
Keep the inverter and cables in good working order and condition. Take
immediate action to repair or replace damaged parts.
Ensure that there is no obstruction to the flow of clean, cool air and
ensure that there are no conductive dust, corrosive vapors, or humidity that
could enter the inverter and cause serious damage.
DO NOT weld containers or pipes which have held flammable materials –
gases, liquids, or solids.
▲ DANGER! Avoid welding on materials cleaned with chlorinated solvents or
near such solvents. Vapors from chlorinated solvents (such as de-greasers) can
be decomposed by the heat of the arc to form PHOSGENE, a highly toxic gas, and
other lung and eye irritating products. The ultraviolet (radiant) energy of
the arc can also decompose trichloroethylene and perchloroethylene vapors to
form phosgene.
DO NOT weld where solvent vapors can be drawn into the welding or cutting
atmosphere or where the radiant energy can penetrate to atmospheres containing
even minute amounts of trichloroethylene or perchloroethylene.
** Prevent dangerous conditions arising by providing adequate ventilation.
NEVER ventilate with oxygen.
▲ DANGER! Lead-, cadmium-, zinc-, mercury- and beryllium-, bearing
materials, when welded (or cut) may produce harmful concentrations of toxic
fumes. Adequate local exhaust ventilation must be used, or each person in the
area, as well as the operator, must wear an air-supplied respirator. For
beryllium, both must be used. Metals coated with or containing materials that
emit toxic fumes should not be heated unless the coating is removed from the
work surface, the area is well ventilated, or the operator wears an air-
supplied respirator.
DO NOT** work in an unventilated confined space. If necessary, wear an air-
supplied respirator.
WARNING!: Generator engine exhaust must be vented to the outside air.
Carbon monoxide can kill.
1.2.3. Protection from Arc
WARNING!: Use a welding head shield to protect your eyes and avoid
exposing skin to ultraviolet rays given off by electric arc. Looking at an arc
momentarily with unprotected eyes (particularly a high-intensity gas-shielded
arc) can cause a retinal burn that may leave a permanent dark area in the
field of vision.
Before welding whilst wearing contact lenses, seek advice from your
optician.
Avoid unintentional contact with the workpiece. Accidental or
uncontrolled arcing on the electrode holder may be dangerous.
DO NOT hit the electrode on the workpiece, this may damage the electrode
and make strike-up difficult.
****Wear safety welding gauntlets
1.2.4. Welding Environment.
Locate the inverter in a suitable work area.
See Section 11 regarding Electromagnetic Compatibility.
**Keep the work area clean and tidy and free from unrelated materials.
Also, ensure that the work area has adequate lighting.
DO NOT get the inverter wet or used it in damp or wet locations or areas
where there is condensation.
**First aid facilities and a qualified first aid person should be available
during welding operations.
For production welding, a separate room or enclosed bay should be
provided. In open areas, surround the operation with low reflective, non-
combustible screens or panels. Allow for free air circulation, particularly at
floor level. Provide face shields for all persons who will be looking directly
at the weld. Before starting to weld, make sure that the screen or bay doors
are closed.
Always ensure that there is full free air circulating around the outer
casing of the machine and that the louvers are unobstructed
1.2.5. Fire Hazard
WARNING: Be aware that flying sparks or falling slag can pass through
cracks, along pipes, through windows or doors, and through wall or floor
openings, out of sight of the operator. Sparks and slag can fly 10m.
DO NOT weld within 10 meters of combustible materials (including building
construction materials).
DO NOT weld adjacent to openings (concealed or visible) in floors or
walls within 10m that can expose combustibles to sparks.
DO NOT weld near walls, ceilings, roofs, or metal partitions where there
are combustibles that can be ignited by radiant or conducted heat.
** Have suitable fire extinguishing equipment available and someone to use
it during welding operations and for some time after welding ceases. After
work is done, check that area is free of sparks, glowing embers, and flames.
1.3. PRODUCT CARE & MAINTENANCE
DO NOT attempt to fit any unapproved electrode holder, components, or parts to
the inverter unit.
**Keep the inverter clean for the best and safest performance.
WARNING: If the case is opened for maintenance or repair, wait 10-15
seconds after the unit is switched off for the capacitor to discharge
INTRODUCTION
Compact and lightweight unit. The unit can arc weld a variety of rods including rutile, basic and stainless from Ø1.6mm up to Ø4mm (see spec table for details). Features thermal cut-out protection. Portability allows the welder to be taken to the job at hand, ideal for mobile technicians. Supplied with 2m 16mm² cable with electrode holder and a 2m 16mm² earth clamp and cable, both with 35-70 quick connectors. Forced air cooling system with 2 fans.
SPECIFICATION
Model No. | MW140i | MW160i |
---|---|---|
Welding Current | 20-140A | 20-160A |
Duty Cycle | 100%@63A | 100%@72A |
60%@81A | 60%@92A | |
20%@140A | 20%@160A | |
Electrode Capacity | 01.6-3.2mm | 01.6-4mm |
Absorbed Power | 5.75kW | 6.9kW |
Supply | 230V | 230V |
Protection | IP21S | I P21S |
PREPARATION
WARNING! Ensure that the inverter is not plugged into the main power
supply before connecting or disconnecting cables. For electrical installation,
see Safety Instructions (Section 1).
WARNING! Failure to follow the electrical safety instructions may affect
the operating performance and could damage the built-in safety system which,
in turn, could result in personal injury or fatality and will invalidate the
warranty.
4.1 WELDING CABLE “ELECTRODE HOLDER” CONNECTION
4.1.1 Before connecting cables, it is important to refer to the electrode
manufacturer’s instructions on the electrode packaging which will indicate the
correct polarity connection for the electrode, together with the most suitable
current to use.
4.2 ARC WELDING
4.2.1 In principle, when ARC welding the Electrode Holder “POSITIVE” is
normally connected to the “POSITIVE” (+) terminal (fig.1).
4.2.2 The WORK CLAMP cable is connected to the terminal not occupied by
the electrode holder cable. The clamp is connected to:
a) The workpiece, or
b) A metallic workbench. The connection must be as close to the proposed weld
as possible.
**WARNING! Cable connectors must be turned into quick plugs fully to
ensure good electrical contact. Loose connections will cause overheating,
rapid deterioration, and loss of efficiency.
DO NOT use welding cables over 10m in length.
With the exception of a metallic workbench DO NOT** connect the return cable
to any metallic structure which is not part of the workpiece, as this will
jeopardize weld quality and may be dangerous.
4.3 BACK PANEL (FIG.1)
Rocker switch. Turns mains power on and off.
4.4 FRONT PANEL (FIG.2)
4.4.1 Welding Current Control: Regulates welding current.
The set value will be displayed in the display panel.
4.4.2 Power Indicator: Illuminates when the machine is switched on and
ready for use.
4.4.3 Alarm Indicator: Illuminates when the circuitry within the machine
overheats. Allowing the inverter to cool down naturally will restore operation
after a period of time. See rating plate for details of duty cycle.
4.4.4 VRD Indicator illuminates when the voltage reduction device is
active. To operate the VRD, press the function button and hold it for 2
seconds. The display will read VRD’ and by turning the Welding Current control dial it can be turned
On’ or `Off’.
4.4.5 The hot Start function is a feature that pumps up the amperage for
a short time when you start the arc. Higher amperage helps to start the arc
easier without sticking the electrode to the base metal. To enable this
feature, press the function button and hold for 2 seconds and VRD is
displayed. Press the function button once more to engage this feature. Rotate
the knob left to adjust to -10 or right to adjust to +10
4.4.6
4.4.7 Arc Force function (or dig) is a feature that senses the drop of the
arc’s voltage caused by arc length shortening. Arc force compensates for the
voltage drop by increasing the amperage. Increased amperage ensures that the
heat stays the same and that the electrode will not stick to the base metal.
To enable this feature, press the function button and hold for 2 seconds, VRD
will be displayed. Press the function button once more to display HS and press
the downward arrow one more time to engage the Arc Force function. Rotate the
knob left to adjust to -10 or right to adjust to +10. Press the button again
in order to exit the menu system.
4.5 ELECTRODES The welding current must be regulated according to the
diameter of the electrode in use and the type of joint to be welded. See
diameter/current chart below.
Electrode Ømm | Minimum Welding Current Amps | Maximum Welding Current Amps |
---|---|---|
1.6 | 25 | 50 |
2.0 | 40 | 80 |
2.5 | 60 | 110 |
3.2 | 80 | 160 |
4.0 | 120 | 200 |
WELDING PROCEDURE
WARNING! Ensure that you read, understand, and follow the safety
instructions. Place the welding mask in front of your face before striking the
arc.
5.1 ARC WELDING
5.1.1 Strike the electrode tip on the workpiece as if you were striking a
match.
**WARNING! DO NOT hit the electrode on the workpiece, as this may damage
the electrode.
5.1.2 As soon as the arc is struck, maintain a distance from the
workpiece equal to the diameter of the electrode. Keep this distance as
constant as possible for the duration of the weld. As you advance along the
workpiece the angle of the electrode must be maintained between 20º and 30º.
See fig.4.
5.1.3 At the finish of the weld, bring the end of the electrode backward
in order to fill the weld crater and then quickly lift the electrode from the
weld pool to extinguish the arc. WARNING!** Hot metal such as electrode
stubs and workpieces should never be handled without gloves.
MAINTENANCE
WARNING! Before carrying out routine maintenance, switch off the welding
and disconnect it from the main power supply.
WARNING! If the welding machine is not functioning properly repairs
should be carried out only by authorized service engineers.
WARNING! Before removing the welding machine panels switch off the
machine and disconnect it from the mains power supply. Wait 10-15 seconds
after the unit is switched off for the capacitor to discharge.
6.1. Periodically remove the casing and, with a low-pressure airflow (max 1bar
or15psi), remove dust from inside the machine.
****DO NOT direct compressed air onto the electronic circuit boards, these
should be cleaned with a very soft brush.
6.2. Ensure that all electrical connections are tight and check the wiring for
damage to the insulation.
6.3. Ensure that the casing is correctly replaced and secured before
attempting to use the inverter.
6.4. Keep the outside of the machine clean by wiping with a soft, dry cloth.
6.5. For any other service or maintenance, contact your local Sealey service
agent.
TROUBLESHOOTING
7.1 If you have a problem with the inverter, check to ensure that the
following are correct:
7.1.1 Check that the welding current is suitable for the diameter and type of
electrode being used.
7.1.2 When the mains switch is on, check that the power lamp is on. If this is
not the case then there may be the main supply problem.
7.1.3 Check the overheat indicator – has the thermal cut-out activated? This
indicates either an over or under voltage or short circuit. If the thermal
interrupter has activated, wait for the machine to cool down before
restarting.
7.1.4 Ensure that you are using the correct supply voltage.
7.1.5Check the machine output and ensure there is nothing causing a short
circuit.
7.1.6 Check that all circuit connections are correct. In particular, check
that the work clamp is correctly attached to the workpiece. Ensure that there
is no grease, paint, etc. on the surface.
RATING PLATE
The rating plate on the inverter gives the following data:
-
Rating of internal protection provided by the casing.
-
The symbol for the power supply line: 1= Single-phase AC.
-
This indicates that welding may be carried out in environments with a heightened risk of electric shock e.g. very close to large metallic objects.
-
Welding procedure: manual arc welding with covered electrode
-
The symbol for the internal structure of the welding machine.
-
Model No.
-
Manufacturers Serial Number for welding machine identification.
-
The EUROPEAN standard relates to the safety and construction of arc welding machines.
-
Output.
Uº: Maximum no load voltage.
I², U²: Current and corresponding normalized voltage that the welding machine can supply during welding.
X: Welding ratio based on a 10-minute duty cycle. 30% indicates 3 minutes welding and 7 minutes rest, and 100 indicates continuous welding.
A/V-A/V: Shows the amount of adjustment for the welding current (min-max) at the corresponding arc voltage. -
Power Supply
U1: Alternating voltage and power supply frequency of welding machine.(allowed limit ± 10%)
I1 max: Maximum current absorbed by the line.
I1 eff: Effective current supplied.
ELECTRONIC COMPATIBILITY
9.1 THIS EQUIPMENT IS IN CONFORMITY WITH THE EUROPEAN STANDARD ON THE
ELECTROMAGNETIC COMPATIBILITY OF ARC WELDING EQUIPMENT AND SIMILAR PROCESSES
(e.g. ARC AND PLASMA CUTTING)
9.2 PROTECTION AGAINST INTERFERENCE. (E.M.C.) The emission limits in this
standard may not, however, provide full protection against interference to
radio and television reception when the equipment is used closer than 30m to
the receiving antenna. In special cases, when a highly susceptible apparatus
is being used in close proximity, additional mitigation measures may have to
be employed in order to reduce the electromagnetic emissions. At the same
time, there could occur some potential difficulties in having electromagnetic
compatibility in a non-industrial environment (e.g. in residential areas).
Therefore it is most important that the equipment is used and installed
according to the following instructions.
9.3 INSTALLATION AND USE. The user is responsible for installing and
using the equipment according to these instructions. If electromagnetic
disturbances are detected, then it shall be the responsibility of the user of
the equipment to resolve the situation with the technical assistance of the
supplier. In some cases, this remedial action may be as simple as earthing the
circuit (see Note). In other cases it would involve constructing an
electromagnetic screen, enclosing the welding power source and the work,
complete with associated input filters. In all cases, the electromagnetic
disturbances shall be reduced to a level where they are no longer troublesome.
Note: The welding/cutting circuit may or may not be earthed for safety
reasons. Changing the earthing arrangements should only be authorized by a
person who is competent to assess whether the changes will increase the risk
of injury, e.g. by allowing parallel welding/cutting circuit return paths
which may damage the earth circuits of other equipment. Further guidance is
given in IEC 974-13 ‘Arc Welding Equipment – Installation and Use.
9.4 ASSESSMENT OF AREA. Before installing the equipment the user shall
make an assessment of potential electromechanical problems in the surrounding
area. The size of the surrounding area to be considered will depend on the
structure of the building and other activities that are taking place. The
surrounding area may extend beyond the boundaries of the premises. The
following shall be taken into account:
a) Other supply cables, control cables, signalling, and telephone cables,
above, below, and adjacent to the welding equipment.
b) Radio and television transmitters and receivers.
c) Computer and other control equipment.
d) Safety critical equipment, e.g. security monitoring of industrial
equipment.
e) The health of people in the vicinity, e.g. persons fitted with a pacemaker
or hearing aid.
f) Equipment used for calibration or measurement.
g) The immunity of other equipment in the environment. The user shall ensure
that other equipment being used in the environment is compatible. This may
require additional protective measures.
h) The time of day that welding and other activities are to be carried out.
9.5 RATING PLATE The equipment should be connected to the main supply
according to these instructions. If interference occurs, it may be necessary
to take additional precautions such as filtering the mains supply.
Consideration should also be given to shielding the supply cable of
permanently installed equipment in metallic conduit or equivalent. This
shielding should be connected to the power source so that good electrical
contact is maintained between the conduit and the welding power source
enclosure. 9.6 MAINTENANCE OF THE EQUIPMENT should be routinely
maintained according to these instructions. All-access and service covers
should be closed and properly fastened when the welding equipment is in
operation. The welding equipment should not be modified in any way except for
those changes and adjustments covered in these instructions. In particular,
the spark gaps of any arc striking and stabilizing devices should be adjusted
and maintained according to the instructions.
9.7 CABLES The welding/cutting cables should be kept as short as possible
and should be positioned close together, running at or close to the floor
level.
9.8 EQUIPOTENTIAL BONDING Bonding of all metallic components in the
welding/cutting installation and adjacent to it should be considered. However,
metallic components bonded to the workpiece will increase the risk that the
operator could receive a shock by touching these metallic components and the
electrode at the same time. The operator should be insulated from all such
bonded metallic components.
9.9 EARTHING OF THE WORKPIECE Where the workpiece is not bonded to earth
for electrical safety, nor connected to earth because of its size and
position, e.g. ship’s hull or building steelwork, a connection bonding the
workpiece to earth may reduce emissions in some, but not all instances. Care
should be taken to prevent the earthing of the workpiece increasing the risk
of injury to others or damage to other electrical equipment. Where necessary,
the connection of the workpiece to the earth should be made by a direct
connection to the workpiece, but in some countries where direct connection is
not permitted, the bonding should be achieved by a suitable capacitance,
selected according to national regulations.
9.10 Selective screening and shielding of other cables and equipment in the
surrounding area may alleviate problems of interference. Screening of the
entire welding/cutting installation may be considered for special
applications.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories, and packaging should be sorted, taken to a recycling center, and
disposed of in a manner that is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with
the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications, and component parts without
prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 36 months from purchase date, proof of which is
required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
01284 703534
sales@sealey.co.uk
www.sealey.co.uk
© Jack Sealey Limited
Original Language Version
MW140i, MW160i Issue:1 24/11/21
Read User Manual Online (PDF format)