PR-41552-BAS Pressure Injectable Arrowg+ard Blue Advance® Two-Lumen Midline User Guide

June 4, 2024
Arrow

User GuidePR 41552 BAS Pressure Injectable Arrowg ard Blue Advance® Two
Lumen Midline

PR-41552-BAS

5.5 Fr.|

2 Lumen

| 15 cm catheter length| .018 inch dia. spring-wire guide
---|---|---|---

Pressure Injectable Arrowg+ardBlue Advance® Two-Lumen  Midline

Contents:
1: Two-Lumen TaperFree® Catheter with Arrowg+ard Blue AdvanceTM Antimicrobial/Antithrombogenic Protection1: 5.5 Fr. (1.9 mm OD) x 15 cm, Pressure Injectable, Blue FlexTip®
1: GlideThrum Peel-Away Sheath: 5.5 Fr. x 2-3/4″ (7 cm) Radiopaque over 5.5 Fr. Dilator
1: Spring-Wire Guide, Nitinol, Marked: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – Straight Stiff Tip on Other)
1: Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
1: Syringe: 10 mL Luer-Lock
2: Dust Cap: Non-Vented
1: SecondSite™ Adjustable Hub: Fastener
1: SecondSite™ Adjustable Hub: Catheter Clamp
1: SharpsAway® Disposal Cup
1: SharpsAway® II Locking Disposal Cup
1: Catheter Trimmer
1: Safety Scalpel: #11
1: Patient ID Card
1: Patient Information Booklet
1: Paper Tape Measure
1: Dressing: STATLOCK®2 Catheter Stabilization Device
¹Licensed under US Patent No. 7,329,412.
²A registered trademark of C. R. Bard, Inc.

Rx only
Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death.
California Prop. 65
WARNING: Cancer and Reproductive Harm. www.P65Warnings.ca.gov
Not made with natural rubber latex.
Store below 25°C (77°F). Avoid excessive heat above 30°C (86°F).
Fluid path components are non-pyrogenic.
Contraindications: The Arrowg+ard Blue Advance Pressure Injectable Midline is contraindicated for patients with known hypersensitivity to chlorhexidine.

| Priming
Volume*
(mL)| Gravity
Flow
Rate†
(mL/hr)| Pump
Flow
Rate††
(mL/hr)| MAX
Pressure
Injection
Flow Rate**
(mL/sec)
---|---|---|---|---
Distal(18Ga.)
Proximal(18Ga.)| 0.27
0.28| 1071
898| 5860
6060| 5
not rated

  • Priming volumes are approximate and are done without accessories.
    † Flow rate values are approximate and are determined using deionized water at 100 cm head height.
    †† Pump flow rates are determined at a maximum pump pressure of 10 PSIG and represent approximate flow capabilities.
    ** Pressure injection flow rates are determined using media of 11.8 centipoises (cP) viscosity, with 152 cm administration set tubing.

![PR 41541 BAS Pressure Injectable Arrowg ard Blue Advance® One Lumen Midline

****Arrow International LLC
subsidiary of Teleflex Incorporated
3015 Carrington Mill Blvd.
Morrisville, NC 27560 USA

www.teleflex.com
LBL057533 R00 (2021-11)

References