ARROW SA-12702-J Two-Lumen CVC User Manual
- June 4, 2024
- Arrow
Table of Contents
ARROW SA-12702-J Two-Lumen CVC User Manual
Contents
- Two-Lumen Catheter: 7 Fr. (2.5 mm OD) x 16 cm
- 1: Spring-Wire Guide, Marked: .032″ (0.81 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
- 1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
- 1: Injection Needle: 22 Ga. x 1-1/2″ (3.81 cm)
- 1: Injection Needle: 25 Ga. x 1-1/2″ (3.81 cm)
- 1: Injection Needle: 18 Ga. x 1-1/2″ (3.81 cm)
- 1: Introduce Needle: 18 Ga. x 1-1/2″ (3.81 cm) XTW
- 1: Introduce Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW
- 1: Pressure Transduction Probe
- 1: Introduce Needle: 22 Ga. x 2-3/4″ (7 cm) TW
- 1: Syringe: 10 mL Luer-Slip
- 1: Syringe: 3 mL Luer-Lock
- 1: Syringe: 5 mL Luer-Slip
- 1: Arrow® Raulerson Spring-Wire Introduction Syringe: 5 mL
- 1: Tissue Dilator: 8 Fr. (2.7 mm) x 9 cm 2: Dust Cap: Non-Vented
- 1: Second Site™ Adjustable Hub: Fastener
- 1: Second Site™ Adjustable Hub: Catheter Clamp
- 2: Medicine Cup: 60 mL
- 1: Medicine Cup: 100 mL
- 1: Sharps Away® II Locking Disposal Cup
- 1: Sharps Away® Disposal Cup
- 1: Drape: 48″ x 88″ (122 cm x 224 cm) with 3-1/2″ (9 cm) fenestration
- 1: Needle Holder
- 1: Scissors
- 1: Scalpel: #11 2: Stopcock: 4-way
- 1: Label Sheet 2: Prep Sponge Swab
- 6: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
- 1: Dressing: OpSite®1 4-3/4″ x 4″ (12 cm x 10 cm)
- 1: Suture: 3-0 Silk with Curved Needle
- 1: Tray: Prep
1A registered trademark of T.J. Smith & Nephew, Limited.
Safety instruction
Warning: Read all package insert warnings, precautions, and instructions
prior to use. Failure to do so may result in severe patient injury or death.
Not made with natural rubber latex. Sterilized using ethylene oxide unless
otherwise indicated in the contents list. Fluid path components are non-
pyrogenic.
SA-12702-J
- 7 Fr.
- 2 Lumen
- 16 cm catheter length
- .032 inch dia. spring-wire guide
Lumen
|
*Priming Volume (mL)**
|
Gravity Flow Rate† (mL/hr)
---|---|---
Distal (14 Ga.| 0.52| 5212
Proximal (18 Ga.)| 0.38| 1552
Priming volumes are approximate and are done without accessories. † Flow rate values are approximate and are determined using demonized water at 100 cm head height.
Support
Arrow International LLC
Subsidiary of Teleflex Incorporated
3015 Carrington Mill
Blvd. Morrisville, NC 27560 USA
www.teleflex.com
LBL054863 R00 (2021-11)
Read User Manual Online (PDF format)