Scolmore 20A Double Pole Control Switches Instruction Manual
- June 11, 2024
- Scolmore
Table of Contents
20A Double Pole Control Switches
Instruction Manual
20A Double Pole Control Switches
After making the connections, screw the switch plate gently to the back box
ensuring no wires become trapped.
Screw the accessory fully home making sure, when done, the plate is not
distorted.
Mains Wiring:
‘L’ – | Live | Coloured Brown or Red |
---|---|---|
**** | CPC | Coloured Green/Yellow |
‘N’ – | Neutral | Coloured Blue or Black |
Conductor lengths may be trimmed in certain applications.
Decorative accessory plates are not suitable to be mounted onto wet / damp
plaster or paint, as this may cause the accessory to tarnish.
This range is not suitable for outdoor installation or in areas of high
humidity.
For cleaning / polishing of products, use only a soft, dry, clean cloth.
Technical Information
Voltage | 240V— 50Hz |
---|---|
Current Rating | 20A |
Terminal Size | 5mm 0 |
Torque Value | Terminal Screw: 1.8Nm |
Cable Size | 4 x 2.5mm2 |
Back Box Depth (Vin) | 25mm (Deco, Deco+, Mode, Polar, Part M, Curve) 35mm |
(Define, Definite)
Operational Temperature| -5° to +45°C
Standards| The Low Voltage Directive 2014/35/EC Statutory Instruments 2014/35
BS EN 60669-1
Errors & Omissions excluded. Instructions are subject to change without notice.
Wiring Accessories – 20A Double Pole Control Switches
Safety, Installation and Technical Information
Safety Information
Please read the following information carefully before commencing
installation.
Before commencing any electrical work, to prevent the possibility of receiving
an electric shock, ensure the mains isolator on the consumer unit is in the
‘OFF’ position and
safely isolated in accordance with Best Practice Guide 3.
If in doubt consult a qualified electrician. The accessory plate must be
installed in accordance with the latest IET Wiring Regulations, BS7671.
If this product is being fitted as a replacement part to an existing
installation account must be taken to the version of the wiring regulations it
was installed to.
Installation Information
When removing the cables from the terminals, note the cable connections in the
terminal to ensure correct wiring of the new accessory.
The mounting box must be of the correct size for the product, metal or
plastic.
Please see Technical Information overleaf for minimum back box depth, range
dependant.
The cable must be routed through the most suitable entry point of the mounting
box.
Cables should be prepared to the appropriate lengths (as stated within these
instructions) so that the conductor reaches into the terminal, and the circuit
protective conductor is the longest. The terminals should be tightened to
their appropriate torque value. Do not over tighten.
Standard 20A Double Pole Switching
Double Pole switching allows for the safe isolation of both Permanent Live and
Neutral conductors. The below installation example is for direct connection
between the supply and the appliance.
20A Double Pole Switching with Flex Outlet Through Bottom of Plate
Double Pole switching allows for the safe isolation of both Permanent Live and
Neutral conductors. The below installation example is for direct connection
between the supply and the appliance through a flex outlet at the bottom of
the plate.
20A Double Pole Switching with Flex Outlet Through Plate
Double Pole switching allows for the safe isolation of both Permanent Live and
Neutral conductors. The below installation example is for direct connection
between the supply and the appliance through a flex outlet hole.
20A DP Switching with a Sink/Bath Switch
A Sink/Bath switch allows for the safe isolation and control of Dual Immersion
Heaters.
Colmore House | Mariner Litchfield Road Industrial Estate
Tamworth Staffordshire B79 7UL | United Kingdom
T: +44 (0)1827 63454 | F: +44 (0)1827 63362
E: technical@scolmore.com |
www.scolmore.com