Flash-Butrym F7100761 Wash 600 Moving Head Hybrid 3IN1 Light User Manual
- June 11, 2024
- Flash-Butrym
Table of Contents
- Flash-Butrym F7100761 Wash 600 Moving Head Hybrid 3IN1 Light
- Wash 600 Product Information
- Product Safety Information
- Product Usage Instructions
- INTRODUCTION
- SAFETY INFORMATION
- PRODUCT INFORMATION
- INSTALLATION
- CONNECTION
- DMX CHANNELS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Flash-Butrym F7100761 Wash 600 Moving Head Hybrid 3IN1 Light
Wash 600 Product Information
The Wash 600 is a LED Moving Head (LMH) fixture designed for use in various settings such as concerts, events, and theatrical productions. It comes with a powerful pan motor and provides a strong light output. The fixture should be operated with caution and the safety instructions must be followed carefully to ensure proper functioning and avoid any hazards.
Product Safety Information
- Keep the User Manual for future reference and ensure that anyone who uses the fixture also has access to the instruction booklet.
- Check for transportation damage before using the fixture.
- Ensure that the voltage and frequency of power supply match the power requirements of the fixture.
- Ground the yellow/green conductor to earth to avoid electric shock.
- Disconnect main power before servicing and maintenance.
- Use safety chain when fixing the fixture.
- Do not handle the fixture by taking its head only, but always by taking its base.
- If there is a serious operating problem, stop using the fixture immediately and contact the nearest authorized technical assistance center.
- Do not connect the device to any dimmer pack.
- Avoid touching any wire during operation to prevent electric shock.
- Do not expose the fixture to rain or moisture to prevent the risk of electrical shock or fire.
- Replace visibly damaged housing.
- Do not look directly at the Wash 600 while it is on.
Warnings
- The LMH has a powerful pan motor. Do not apply power to the LMH unless the base is securely fastened to a surface or to rigging hardware.
- Use 2 clamps to rig the fixture and lock each clamp with both 1/4-turn fasteners. Fasteners are locked only when turned a full 900 clockwise.
- When clamping the fixture to a truss or other structure at any other angle than with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not use any type of clamp that does not completely encircle the structure when fastened.
- Position or shade the head so that the front lens will not be exposed to sunlight or any other strong light source from any angle. The LMH lens can focus the sun’s rays, creating a potential fire hazard and causing damage.
Important Note
Do not point strong light output from other fixtures at the LMH as intense illumination can damage the display.
Product Usage Instructions
- Check for transportation damage before using the fixture.
- Before operating, ensure that the voltage and frequency of power supply match the power requirements of the fixture.
- Ground the yellow/green conductor to earth in order to avoid electric shock.
- Use safety chain when fixing the fixture and always handle it by taking its base.
- Do not connect the device to any dimmer pack.
- Avoid touching any wire during operation to prevent electric shock.
- Do not expose the fixture to rain or moisture to prevent the risk of electrical shock or fire.
- Replace visibly damaged housing.
- Position or shade the head so that the front lens will not be exposed to sunlight or any other strong light source from any angle.
- Do not point strong light output from other fixtures at the LMH as intense illumination can damage the display.
INTRODUCTION
THANK YOU FOR PURCHASING WASH 600. FOR SAFETY REASONS AND TO ENSURE THE TROUBLE-FREE OPERATION, CAREFULLY READ THE INSTRUCTIONS.
SAFETY INFORMATION
- Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet.
- Unpack and check carefully there is no transportation damage before using the fixture.
- Before operating, ensure that the voltage and frequency of power supply match the power requirements of the fixture.
- It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
- Disconnect main power before servicing and maintenance.
- Use safety chain when fixes this fixture. Don’t handle the fixture by taking its head only, but always by taking its base.
- Maximum ambient temperature is: 40°C Don’t operate it where the temperature is higher than this.
- In the event of serious operating problem, stop using the fixture immediately. Never try to repair the fixture by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
- Do not connect the device to any dimmer pack.
- Do not touch any wire during operation and there might be a hazard of electric shock.
- To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.
- The housing must be replaced if they are visibly damaged.
- Do not look directly at the Wash 600 while the fixture is on.
WARNING
- WARNING! The Led Moving Head (LMH) has a powerful pan motor. The torque reaction when the head is panned suddenly can cause the base to move if the fixture is standing unsecured on a surface. Do not apply power to the LMH unless the baase is securely fastened to a surface or to rigging hardware.
- WARNING! Use 2 clamps to rig the fixture. Do not hang the fixture from only one clamp. Lock each clamp with both 1/4-turn fasteners. Fasteners are locked only when turned a full 900 clockwise.
- WARNING! When clamping the fixture to a truss or other structure at any other angle than with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not use any type of clamp that does not completely encircle the structure when fastened.
- WARNING! Position or shade the head so that the front lens will not be exposed to sunlight or any other strong light source from any angle – even for a few seconds. See Figure 1. The LMH lens can focused the sun’s rays, creating a potential fire hazard and causing damage.
- IMPORTANT! Do not point strong light output from other fixtures at the LMH, as intense illumination can damaged the display.
Figure 1. Lenses can focused sunlight and strong light, presenting a risk of fire and damage to the fixture. Shield or shade the head if necessary.
PRODUCT INFORMATION
- Light Source: 37x15W 4in1 RGBW
- Power consumption: 480W
- Power supply voltage: 100-245V, 50/60Hz AC
- PAN range: 540°
- TILT range: 270°
- Beam angle (min/max): 5°~60°
- Luminous Flux: Distance 5m –> 5° (7149 lx) 30° (917 lx)
- Zoom: Yes
- Features: 3 sections, CTO, Color Macros,
- Operating modes: DMX 512, Auto-running, Master/Salve, 10/15/21/37/46 DMX channel mode.
- IP Rating: IP20
- Housing made: ABS
- Cooling: Active
- AC IN/OUT: PowerCON 3-Pin/5-Pin XLR DMX Input/Output
- Net Weight: 13,6 kg
- Weight with packaging: 15,5 kg
- Dimensions: H(48)xW(37)xD(27) cm
- Carton Box: H(49)xW(38)xD(46) cm
INSTALLATION
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it.
CONNECTION
The device is equipped with the following interfaces:
- DMX (in/out): XLR 3(5)-pin socket
- Power (in/out): powerCON socket
Connecting DMX signal
The connection is performed using cable with XLR-female -> XLR-Male plugs.
CAUTION! At the last fixture, the DMX signal has to be terminated with a terminator. Solder a 120Ω resistor between signal (-) and signal (+) into a XLR plug and plug it in the DMX output of the last fixture.
Voltage specification
Input Voltage | Total Power | Frequency |
---|---|---|
100~240V AC | 480W | 50/60Hz |
Connecting power supply
The connection is performed using power cable with PowerCon connector
(included). The device must be operated by qualified personnel.
Make sure that the power grid supply parameters are consistent with device
parameters and limitations are not exceeded.
CAUTION! In the case of cable damage do not attempt to repair.
Replacement or repair can be made only on the manufacturer or by a person with
appropriate permissions.
Using lamp, the change rate of power voltage should be within±10%, if the
voltage is too high, it will shorten the light’s life; if it’s not enough, the
lamp will be dark. Please restart it after turning off light for 20 minutes
until full-cooling. Frequent switching will reduce the life span of lamps and
bulbs; intermittent using will improve the life of bulbs and lamps.
Set DMX Address Code
- Press „Menu”(Home) to „Set DMX Address”, and press „ENTER” keys to enter into.
- Show „Set DMX Address DMX Address: 001”, Press the „UP and DOWN” keys to amended
- Press „ENTER” keys to save and Exit, Press the „MENU” (Home) Keys does not save and Exit.
DMX CHANNELS
CH | 10 CH | 15 CH | 21CH | 37 AC CH | 46 CH | 25 CH | 18 CH | 37 BC CH |
---|---|---|---|---|---|---|---|---|
1 | Pan | Pan | Pan | Pan | Pan | Pan | Pan | Pan |
2 | Pan fine | Pan fine | Pan fine | Pan fine | Pan fine | Pan fine | Pan fine | Pan |
fine
3| Tilt| Tilt| Tilt| Tilt| Tilt| Tilt| Tilt| Tilt
4| Tilt fine| Tilt fine| Tilt fine| Tilt fine| Tilt fine| Tilt fine| Tilt
fine| Tilt fine
5| Pan / Tilt speed| Pan / Tilt speed| Pan / Tilt speed| Pan / Tilt speed| Pan
/ Tilt speed| Pan / Tilt speed| Pan / Tilt speed| Pan / Tilt speed
6| Reset| Reset| Reset| Reset| Zoom| Zoom| Zoom| Reset
7| Color wheel| Red all zones| Red| Red 1| Dimmer| Dimmer| Dimmer| Zoom
8| Zoom| Green all zones| Red fine| Red fine 1| Strobe| Strobe| Strobe|
9| Strobe| Blue all zones| Green| Green 1| | Red| Red| Strobe
10| Dimmer| White all zones| Green fine| Green fine 1| | Green| Green| Dimmer
11| | Ctc| Blue| Blue 1| | Blue| Blue|
12| | Color wheel| Blue fine| Blue fine 1| | White| White| Ctc
13| | Zoom| White| White 1| Ctc| Ctc| Ctc| Macro color ring
14| | Strobe| White fine| White fine 1| Macro color ring| Macro color ring|
Macro color ring| Red 1
15| | Dimmer| Ctc| Red 2| Macro color ring speed| Macro color ring speed|
Macro color ring speed| Red fine 1
16| | | Color wheel| Red fine 2| | | | Green 1
17| | | Zoom| Green 2| | | | Green fine 1
18| | | Zoom fine| Green fine 2| Reset| Reset| Reset| Blue 1
19| | | Strobe| Blue 2| Red sec. 1| Dimmer sec. 1| | Blue fine 1
20| | | Dimmer| Blue fine 2| Green sec. 1| Dimmer sec. 2| | White 1
21| | | Dimmer fine| White 2| Blue sec. 1| Dimmer sec. 3| | White fine 1
22| | | | White fine 2| White sec. 1| Dimmer sec. 4| | Red 2
23| | | | Red 3| Red sec. 2| Dimmer sec. 5| | Red fine 2
24| | | | Red fine 3| Green sec. 2| Dimmer sec. 6| | Green 2
25| | | | Green 3| Blue sec. 2| Dimmer sec. 7| | Green fine 2
26| | | | Green fine 3| White sec. 2| | | Blue 2
CH| 10 CH| 15 CH| 21CH| 37 AC CH| 46 CH| 25 CH| 18 CH| 37 BC CH
---|---|---|---|---|---|---|---|---
27| | | | Blue 3| Red sec. 3 A| | | Blue fine 2
28| | | | Blue fine 3| Green sec. 3 A| | | White 2
29| | | | White 3| Blue sec. 3 A| | | White fine 2
30| | | | White fine 3| White sec. 3 A| | | Red 3
31| | | | Ctc| Red sec. 3 B| | | Red fine 3
32| | | | Color wheel| Green sec. 3 B| | | Green 3
33| | | | Zoom| Blue sec. 3 B| | | Green fine 3
34| | | | Zoom fine| White sec. 3 B| | | Blue 3
35| | | | Strobe| Red sec. 4 A| | | Blue fine 3
36| | | | Dimmer| Green sec. 4 A| | | White 3
37| | | | Dimmer fine| Blue sec. 4 A| | | White fine 3
38| | | | | White sec. 4 A| | |
39| | | | | Red sec. 4 B| | |
40| | | | | Green sec. 4 B| | |
41| | | | | Blue sec. 4 B| | |
42| | | | | White sec. 4 B| | |
43| | | | | Red sec. 4 C| | |
44| | | | | Green sec. 4 C| | |
45| | | | | Blue sec. 4 C| | |
46| | | | | White sec. 4 C| | |
MENU (Manual)
SETUP – > enter–>
- Dmx addr–> enter –> 001-512
- Encoder –> enter –> yes / no
- Pan rev –> enter –> yes / no
- Tilt rev –> enter –> yes / no
- advance
MODE – > enter –>
- Run mode –> enter –> dmx / auto / sound
- Chanel –> enter –> 10 / 15 / 21 / 37 AC / 46 / 25 / 18 / 37 BC
MANUAL ( HAND ) – > enter –>
- X
- X fine
- Y
- Y fine
- XY speed
- focus
- dimmer
- Strobe
- Red
- Green
- Blue
- White
- Color temp
- Dynamic
- Speed
- Back
- Back dimmer
- Reset
SHOW –> enter –>
- Language –> English / china
- Reverse –> yes / no
- Backlight –> yes / no
- version
INFORMATION –> enter –> code / time / hall
PLANT –> enter –> password
Read User Manual Online (PDF format)