GENERAL LIFE FC220 Digital Fan Coil Thermostat
Specifications :
- User-Friendly Interface
- For 2 pipe systems
- Manual heating and cooling option
- 3 Stage Fan Speed
- Large LCD Display & Backlight
- Touch Button
- Dimensions (H / W / D): 90mm / 145mm / 27mm
- Operating Current : 110-220V AC 50/60 Hz
- Relay NO Switching Current
- Temperature Measurement Accuracy : 0.1°C
- Operating Sensitivity
- Operating Temperature Range
- Operating Temperature
- Storage Temperature
Product Usage Instructions
Fan Coil Thermostat Placement:
To mount FC220 on the wall, separate the upper case from the bottom case using a screwdriver.
Fan Coil Thermostat Wiring Diagram:
Refer to the provided wiring diagram for proper installation.
Fan Coil Thermostat Working Logic:
Heating Mode: The thermostat monitors the ambient temperature and controls the fan coil unit operation to maintain the set temperature.
Cooling Mode: Similar to Heating Mode, but for cooling operations.
FAQ:
- What is the operating current of FC220?
- The operating current of FC220 is 110-220V AC 50/60 Hz.
- How often does the thermostat measure the temperature of its environment?
- The thermostat measures the temperature every 5 seconds to ensure accurate control.
GENERAL SPECIFICATIONS
FC220 is a digital fan coil thermostat. The user can adjust the Fan Coil Thermostat with the required temperature and fan speed to get more comfortable and economical heating/cooling.
- User-Friendly Interface
- For 2 pipe systems
- Manual heating and cooling option
- 3 Stage Fan Speed
- Large LCD Display & Backlight
- Touch Button
FC220 and equipments
- FC220 Fan Coil Thermostat
- Dowels and Screws
FAN COIL THERMOSTAT
FAN COIL THERMOSTAT PLACEMENT
In order to mount FC220 to the wall, separate the upper case from the bottom case with the help of a screwdriver from the places as shown below
Fan Coil Thermostat needs to be placed in the room which is used most frequently. For instance; the living room or lounge. Placing the Fan Coil Thermostat in a spot that has air circulation like the entrance of a room or the side of the window should be avoided. Also anywhere close to heating units (such as radiator, stove, etc.) and spots where get direct sun lights would not be suitable. Fan Coil Thermostat needs to be located above the floor 150 cm height. Few trials may be made to find the most convenient spot.
FAN COIL THERMOSTAT WIRING DIAGRAM
FC220 SETTINGS MENU
While your device is on, regardless of heating or cooling mode, press and hold
the temperature adjustment buttons “ “, “ “ at the same time for 2 seconds.1st
Menu which is the Temperature Calibration Menu will appear on the screen. You
can use “ “ or “ “ buttons to switch between menus.In order to enter the menu
you want to adjust, press and hold the temperature adjustment buttons “ ”, “ “
at the same time for 2 seconds.After adjustments are completed, press and hold
the temperature adjustment buttons “ “, “ “ at the same time for 2 seconds to
exit the menu.
In order to exit the settings menu completely, press and hold the temperature
adjustment buttons “ ”, “ “ at the same time for 2 seconds while in the 6th
menu.
The settings you made have been saved and your Fan Coil Thermostat has
returned to the main screen.
Settings Menu respectively;
Calibration Menu ( See Image 1 )Temperature sensors used in Fan Coil
Thermostats are highly precise. If you want to synchronize the temperature
with the thermometers in your living space, you need to calibrate your Fancoil
Thermostat. In order to do this:
Set the temperature difference you want from the calibration menu you see by
pressing “ ” or “ ”. This value can be adjusted between “-8°C” and “+ 8°C”. o
Note: The recommended temperature calibration setting is “0.0 C”.
Operating Range Minimum Temperature Set Value Menu ( See Image 2)
In this menu, you can change the operating range minimum temperature set o value while using your Fan Coil Thermostat. This value is 5.0 C by default.
Operating Range Maximum Temperature Set Value Menu (See Image 3)
In this menu, you can change the operating range maximum temperature set o value while using your Fan Coil Thermostat. This value is 35.0 C by default.
Hysteresis Menu (See Image 4)
Your Fancoil Thermostat has a 0.5°C operating sensitivity by default. This value can be adjusted between “-0.1°C” and “+ 1.0°C”.
Temperature Unit Menu (See Image 5)
Your Fancoil Thermostat operates in a Celcius unit by default. In this menu,
you can change the temperature unit to Celcius or Fahrenheit.
Exit(See Image 6)
The exit menu saves the changes you have made and allows you to use your Fan
Coil Thermostat.
FAN COIL THERMOSTAT WORKING LOGIC
Heating Mode
Your Fan Coil Thermostat measures the temperature of its environment every 5 seconds. If the ambient temperature rises 0.5 degrees above the temperature you have set, your Fan Coil Thermostat will stop the operation of fan coil unit, if it falls below 0.5 degrees, it initiates the operation of fan coil unit. Thus, it ensures that the ambient temperature remains within a certain range.
Cooling Mode
Your Fan Coil Thermostat measures the temperature of its environment every 5 seconds. If the ambient temperature rises 0.5 degrees above the temperature you set, your Fan Coil Thermostat will initiate the operation of fan coil unit, if it falls below 0,5 degrees,it stops the operation of fan coil unit. Thus, it ensures that the ambient temperature remains within a certain range.
DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.
Brand: GENERAL Life
Product Name : FC220
Product Type : Digital Fan Coil Thermostat
Compatible Directives: Electromagnetic Compatibility Regulation
2014/30/EU
(EMC EN 61000-6-3: 2007 + A1: 2011, EN 61000-6-1: 2007)
Low Voltage Directive 2014/35/EU
(LVD EN 60730-2-9:2010, EN 60730-1:2011)
Additional Information: The mentioned product can be used with 2 pipe fan coil
systems and compliance with the directives only covers the product.
ISIPARK is not responsible for the entire system’s compliance with the
directives. This statement is not valid if changes are made to the product
without our approval.
Additional Information: The mentioned product can be used with 2 pipe fan coil systems and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval.
WARRANTY CONDITIONS
-
The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years.
-
Devices and equipment are delivered to the customer in working condition in our company. On-site commissioning is subject to a service fee.
-
The repair of the devices and types of equipment are covered by the warranty is carried out in our company factory and should be sent by a contracted transportation company. In on-site services, the transportation and accommodation expenses of the service personnel belong to the customer. The shift fee during the transportation is added to the service fee and collected in advance.
-
The maintenance of devices and equipment are done in our company.
For the maintenance of the devices and equipment, the round travel fares belong to the customer. -
In case of malfunctioning of the devices and equipment whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault, and it is reported with a report issued by our company.
-
In case of detection of manufacturer-induced errors of devices and equipments whose warranty period continues, the customer can request a replacement or repair of the devices and equipment at full expense by the manufacturer, unless it’s higher than the product’s price.
-
In the event that the faults of the devices and equipment whose warranty period continues are determined as caused by the customer, all expenses would belong to the customer.
-
Customers should be aware of damages (if there is any) of the product and warn the manufacturer since the day the warranty duration starts.If the customer do not warn the manufacturer with knowledge of the damage, the customer loses the rights of article 6.
-
Malfunctions resulting from the use of devices and equipment contrary to the matters stated in the User Manual are not covered by the warranty.
-
Devices and their equipment are out of warranty if they are beaten, broken or scratched by the customer.
-
Damages resulting from the use of devices and equipment belonging to other brands and models without the approval of the manufacturer are not covered by the warranty.
-
Errors that may occur due to rust, oxidation, and liquid contact working in acidic/humid environments are not covered by the warranty.
-
Damages that may occur during the transportation of devices and equipment are not covered by the warranty. Customers can take transportation insurance.
-
Damages caused by mains voltage / faulty electrical installation are not covered by the warranty.
-
Devices and equipments are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake etc.
-
All of the devices and pieces of equipment, including all their parts, are under the warranty of our company.
-
In case of malfunction of the devices and equipment within the warranty period, the time spent during the repair period is added to the warranty period. The repair period of the product cannot exceed 20 working days. This period starts from the date of notification to the service station of the malfunction related to the product or, in the absence of a service station, to the seller, dealer, agency, representative, importer or manufacturer of the product. Consumers can report the problem by; phone, fax, e-mail, registered and reply paid letter or a similar way. However,in case of a conflict, the responsibility of proving is belongs to the customer. If the malfunction of the product is not repaired within 20 working days, the manufacturer-producer or importer; has to allocate another product with similar features to the use of the consumer until the repair of the product is completed,
-
Although the consumer uses his/her repair rights,
- If the product breaks down for 4 times in a year or 6 times in warranty duration and these problems affect the main purpose of the product. (starting from delivery time during warranty.)
- Exceeding the maximum time required for repair,
- In the event that the service station is not available, if it is determined that the repair of the defect is not possible with the report prepared (in order) by one of the seller, dealer, agency, representative, importer or manufacturer, a refund or a price discount at the rate of defect can be requested.
-
The customer can make complaints and appeals to consumer courts or consumer arbitration committees.
-
The warranty document must be kept by the customer during the warranty period. If the document is lost, a second document will not be issued. In case of loss, repair and replacement of devices and equipment will be made for a fee.
WARRANTY CERTIFICATE
Manufacturer
- Title : ISIPARK İÇ DIŞ TİC. A.Ş.
- Adress: Fatih Mah. 1188 Sk. No:13/A Sarnıç Gaziemir İzmir-TÜRKİYE
- Tel: +90 (232) 457 99 50
- Fax: +90 (232) 457 91 22
- E-mail: generallife@generallife.com.tr
- Authorised Signatory:
- Company Stamp:
Product
- Type: Digital Fan Coil Thermostat
- Brand: GENERAL Life
- Model: FC220
- Guarantee Period: 5 Years