GENERAL LIFE FH102S Underfloor Heating Thermostats Instruction Manual

June 1, 2024
GENERAL LIFE

GENERAL-LIFE-Logo

GENERAL LIFE FH102S Underfloor Heating Thermostats

GENERAL-LIFE-FH102S-Underfloor-Heating-Thermostats-
Product

Product Information

General Specifications
FH102S is a floor heating room thermostat that provides comfortable and affordable heating by allowing users to set the desired room temperature.

  • Sensitive Temperature Measurement
  • Wired Connection
  • ON/OFF Control

Technical Data

  • Dimensions (H/L/W): 150 cm
  • Operating Current
  • Relay NO Switching Current
  • Temperature Measurement Accuracy
  • Operating Sensitivity
  • Operating Temperature Range
  • Operating Temperature Storage Temperature

FH102S and Equipments

  • FH102S Room Thermostat
  • Dowels and Screws

Product Usage Instructions

Room Thermostat Placement
Place the Room Thermostat in a frequently used room in your living space such as the hall or living room. Avoid areas with high air circulation, near heating units, or direct sunlight. The recommended height for placement: is 150 cm from the floor.

Warning!
The assembly of the product should be done according to the provided wiring diagram. Electrical connections should be made as per diagram 5. Do not use a wiring centre.

Specifications

Declaration of Conformity
The FH102S Floor Heating Room Thermostat by GENERAL Life complies with the following directives:

  • Electromagnetic Compatibility Regulation 2014/30/EU
  • Low Voltage Directive 2014/35/EU

Warranty Certificate

  • Warranty Period: 2 Years
  • Max. Time to Repair: 20 Days

Frequently Asked Questions (FAQ)

  • Q: Can the FH102S thermostat be used with any heating system?
    A: The FH102S thermostat can be used with boilers that have on/off output. Ensure compliance with the specified directives for optimal performance.

  • Q: What should I do if the indicator LED does not light up?
    A: Check the power supply and wiring connections to ensure proper functionality of the thermostat.

GENERAL SPECIFICATIONS

FH102S is a floor heating room thermostat. The user provides more comfortable and affordable heating by setting the needed room temperature.

  • Sensitive Temperature Measurement
  • Wired Connection
  • ON/OFF Control

FH102S AND EQUIPMENT

GENERAL-LIFE-FH102S-Underfloor-Heating-Thermostats-Fig-
\(1\)

TECHNICAL DATA

Dimensions ( H/L/W) 85.7mm/85.7mm/33.5mm
Operating Current 230V AC
Relay NO Switching Current 7A (240VAC – Resistive load)

10A (120VAC – Resistive load)

Temperature Measurement

Accuracy

| 0.1oC
Operating Sensitivity| 0.5oC
Operating Temperature Range| (5oC) – (30oC)
Operating Temperature| (-10oC) – (+50oC)
Storage Temperature| (-20oC) – (+60oC)

ROOM THERMOSTAT

GENERAL-LIFE-FH102S-Underfloor-Heating-Thermostats-Fig-
\(2\)

Room Thermostat Indicator LED Descriptions

LED light is on The heating unit is working
LED light is off The heating unit is not working

ROOM THERMOSTAT PLACEMENT

Place your Room Thermostat in a room you use frequently in your living space. For example; the hall or living room of your home. Avoid installing the Room Thermostat in places where there is a lot of air circulation, such as at the doorway or by the window. Also, do not place it close to heating units (heater core, fireplace, etc.) and in direct sunlight. We recommend that the room thermostat be placed at a height of 150 cm from the floor.

GENERAL-LIFE-FH102S-Underfloor-Heating-Thermostats-Fig-
\(3\)

ROOM THERMOSTAT WORKING PRINCIPLE

  • As soon as you energize your Room Thermostat, it will start working. Your Room Thermostat measures the temperature of the environment it is in every 5 seconds. If the ambient temperature rises 0.5 degrees above the temperature you set, your Room Thermostat turns off the heating unit, and if it falls below 0.5 degrees, it turns on the heating unit.
  • If the floor sensor measures temperature above 28°C, it turns off the heating unit. The floor sensor operating sensitivity is ±1°C.*
  • Thus, it is ensured that the ambient temperature remains within a certain range.

The external floor sensor is only active when it is connected.

Note:
If a floor sensor is installed with a Room Thermostat, only a GENERAL Life floor sensor should be installed. Otherwise, the product will be out of warranty.

ROOM THERMOSTAT WIRING DIAGRAM

GENERAL-LIFE-FH102S-Underfloor-Heating-Thermostats-Fig-
\(4\)

WIRING DIAGRAM

WIRING DIAGRAM FOR ACTUATOR

GENERAL-LIFE-FH102S-Underfloor-Heating-Thermostats-Fig-
\(5\)

WIRING DIAGRAM FOR WIRING CENTER

GENERAL-LIFE-FH102S-Underfloor-Heating-Thermostats-Fig-
\(6\)

WARNING!
Operations related to the control panel, heating unit or electrical installation must be carried out by persons with professional qualifications.

DECLARATION OF CONFORMITY

ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head office and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.

  • Brand: GENERAL Life
  • Product Name: FH102S
  • Product Type: Floor Heating Room Thermostat

Compatible Directives:

  • Electromagnetic Compatibility Regulation 2014/30/EU
  • (EN 61000-6-1:2019, EN 61000-6-3:2021)
  • Low Voltage Directive 2014/35/EU (EN 60730-2-9)

Additional Information:
The mentioned product can be used with boilers with on/off output and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval.

WARRANTY

WARRANTY CONDITIONS

  1. The warranty period starts from the invoice date and is warranted against manufacturing defects for 2 years.
  2. Devices and apparatus are delivered to the customer in working condition in our company. On-site commissioning is subject to a service fee.
  3. The repair of the devices and apparatus covered by the warranty is carried out in our company factory and should be sent by a contracted transportation company. In on-site services, the transportation and accommodation expenses of the service personnel belong to the customer. The shift fee during transportation is added to the service fee and collected in advance.
  4. The maintenance of devices and apparatus is done in our company. For the maintenance of the devices and apparatus, the round travel fares belong to the customer.
  5. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault, and it is reported with a report issued by our company.
  6. In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair of the devices and apparatus at full expense by the manufacturer, unless it’s higher than the product’s price.
  7. If the faults of the devices and apparatus whose warranty period continues are determined as caused by the customer, all expenses would belong to the customer.
  8. Customers should be aware of damages (if there are any) to the product and warn the manufacturer from the day the warranty duration starts. If the customer does not warn the manufacturer with knowledge of the damage, the customer loses the rights of Article 6.
  9. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty.
  10. Devices and their apparatus are out of warranty if they are beaten, broken or scratched by the customer.
  11. Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty.
  12. Battery leakage and errors due to rust, oxidation and liquid contact by working in acidic/humid environments are not covered by the warranty.
  13. When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that will occur are out of warranty.
  14. Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. Customers can take transportation insurance.
  15. Damages caused by mains voltage / faulty electrical installation are not covered by the warranty.
  16. Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake etc.
  17. All of the devices and apparatuses, including all their parts, are under the warranty of our company.
  18. In case of malfunction of the devices and apparatuses within the warranty period, the time spent during the repair period is added to the warranty period. The repair period of the product cannot exceed 20 working days. This period starts from the date of notification to the service station of the malfunction related to the product or, in the absence of a service station, to the seller, dealer, agency, representative, importer or manufacturer of the product. Consumers can report the problem by; phone, fax, e-mail, registered and reply paid letter or a similar way. However, in the case of a conflict, the responsibility is proving to belong to the customer. If the malfunction of the product is not repaired within 20 working days, the manufacturer-producer or importer; has to allocate another product with similar features to the use of the consumer until the repair of the product is completed.
  19. Although the consumer uses his/her repair rights,
    • If the product breaks down 4 times in a year or 6 times in warranty duration these problems affect the main purpose of the product. (starting from delivery time during warranty.)
    • Exceeding the maximum time required for repair,
    • If the service station is not available, if it is determined that the repair of the defect is not possible with the report prepared (in order) by one of the seller, dealer, agency, representative, importer or manufacturer, a refund or a price discount at the rate of defect can be requested.
  20. The customer can make complaints and appeals to consumer courts or consumer arbitration committees.
  21. The warranty document must be kept by the customer during the warranty period. If the document is lost, a second document will not be issued. In case of loss, repair and replacement of devices and apparatus will be made for a fee.
WARRANTY CERTIFICATE

GENERAL-LIFE-FH102S-Underfloor-Heating-Thermostats-Fig-
\(8\)GENERAL-LIFE-FH102S-Underfloor-
Heating-Thermostats-Fig- \(9\)

ISIPARK reserves the right to change product specifications and user manuals.

For all changes, you may visit generallife.com.tr.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals