General Specifications

  • Digital room thermostat designed for underfloor heating
    system

  • Sensitive temperature measurement

  • Hysteresis adjustment

  • Temperature calibration

  • ON/OFF control

  • Wired connection

  • Floor sensor temperature setting

Technical Data

  • Dimensions (H/L/W)
  • Operating current
  • Relay NO switching current
  • Temperature measurement accuracy
  • Operating sensitivity
  • Operating temperature range
  • Storage temperature

Room Thermostat Placement
Place the Room Thermostat in a frequently used room in your  iving space, such as the hall or living room. Avoid areas with high air circulation, near heating units, or direct sunlight. Mount the thermostat at a height of 150 cm from the floor.

Temperature Calibration
Calibrate the Room Thermostat based on the actual temperature in your living space. Follow these steps:

  1. Turn off the device and press and hold the button for 3 seconds.
  2. Press the button until the calibration menu appears.
  3. Adjust sensitivity by turning the button right or left.
  4. Press the button to save settings and exit.

FH251S USER MANUAL

GENERAL SPECIFICATIONS

FH251S is a digital room thermostat designed for an underfloor heating system. User provides more comfortable and affordable heating by setting needed room temperature.

  • Sensitive Temperature Measurement Hysteresis Adjustment
  • Temperature Calibration ON/OFF Control
  • Wired connection
  • Floor sensor temperature setting

FH251S AND EQUIPMENT

GENERAL-LIFE-FH251S-Underfloor-Heating-Thermostat-
\(2\)

TECHNICAL DATA

GENERAL-LIFE-FH251S-Underfloor-Heating-Thermostat-
\(3\)

ROOM THERMOSTAT

GENERAL-LIFE-FH251S-Underfloor-Heating-Thermostat-
\(5\) * External floor sensor is only active when it is connected.
ROOM THERMOSTAT PLACEMENTPlace your Room Thermostat in a room you use frequently in your living space. For example; like the hall or living room of your home. Avoid installing the Room Thermostat in places where there is a lot of air circulation, such as at the doorway or by the window. Also, do not place it close to heating units (heater core, fireplace, etc.) and in direct sunlight. We recommend that the room thermostat is placed at a height of 150 cm from the floor.

GENERAL-LIFE-FH251S-Underfloor-Heating-Thermostat-
\(6\)

ROOM THERMOSTAT TEMPERATURE CALIBRATION

Temperature sensors used in Room Thermostats are very sensitive.
Based on the temperature on the thermometers in your living space you need to calibrate your Room Thermostat. For this:

  • While your device is off, press and hold the button for 3 seconds.
  • Press the button until you see the calibration menu that says press it. The temperature difference you want from the calibration menu, Adjust by turning the button to the right or left. This value can be adjusted between “-8°C” and “+8°C”.
  • Press the button until the device turns off to save the settings and exit.

Note: Recommended temperature calibration setting is “0.0 C”.

ROOM THERMOSTAT HYSTERESIS POSITIVE MENU
The hysteresis positive factory setting of your Room Thermostat is 0.5°C. This value can be adjusted between “0.1°C” and “2.0°C”. While the hysteresis positive value is 0.5°C, your Room Thermostat will send a command to your heating unit when the room temperature rises 0.5°C above the set temperature. For example, when we set the Room
Thermostat to 22.0°C, your heating unit will stop when the room temperature rises to 22.5°C. To change the hysteresis positive setting:

  • While your device is off, press and hold the button for 3 seconds.
  • Press the button until you see the calibration menu that says  press it. The temperature difference you want from the calibration menu, Adjust by turning the button to the right or left. This value can be adjusted between “-8°C” and “+8°C”.
  • In the hysteresis positive menu, you can adjust the operating sensitivity by turning the button to the right or left.
  • Press the button until the device turns off to save the settings and exit.
  • The settings you have made have been saved. When you turn on your device, it will work with the operating sensitivity you have set.

ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU
The hysteresis-negative factory setting of your Room Thermostat is -0.5°C. This value can be adjusted between “-0.1°C” and “-2.0°C”. While the hysteresis negative value is -0.5°C, your Room Thermostat will send a command to your heating unit when the room temperature drops 0.5°C below the set temperature. For example, when we set the Room
Thermostat to 22.0°C, your heating unit will work when the room temperature drops to 21.5°C. To change the hysteresis negative setting:

  • While your device is off, press and hold the button for 3 seconds.
  • Press the button until the “menu appears.
  • In the hysteresis negative menu, you can adjust the operating sensitivity by turning the button to the right or left.
  • Press the button until the device turns off to save the settings and exit.
  • The settings you have made have been saved. When you turn on your device, it will work with the operating sensitivity you have set.

FLOOR SENSOR TEMPERATURE SETTING MENU
If a floor sensor is installed with Room Thermostat, only GENERAL Life floor sensor should be installed. Otherwise, the product will be out of warranty.
*In case of floor sensor connected, the following settings apply.

The factory temperature setting for floor sensor is 28°C. This value can be adjusted between 23°C and 34°C. The floor sensor operating sensitivity is 1°C. For example, when you set the floor sensor temperature to 28°C, your Room Thermostat will stop the heating unit from working when the floor temperature rises to 29°C. When the floor temperature drops to 27°C, it starts the heating unit of the Room Thermostat. To change the floor sensor temperature:

  • Press and hold the button for 3 seconds while your device is off.
  • Press the button until the menu appears.
  • Adjust the operating temperature by turning the button to the right or left in the floor sensor temperature menu that appears.
  • Press the button until the device turns off to save the settings and exit.
  • The settings you have made have been saved. When you turn on your device, it will operate at the floor sensor temperature you have set.

FACTORY RESET

You can reset the Room Thermostat to its factory default settings. This action resets the calibration setting and hysteresis settings to the factory setting. To factory reset your Room Thermostat:

  • While your device is off, press and hold the button for 3 seconds.
  • Press the button until the menu appears.
  • While in the menu, turn the button to the right or left, select the“ ” option and press the button.
  • Your device will turn off and reset to factory settings.

ROOM THERMOSTAT WORKING PRINCIPLE
As soon as you energize your Room Thermostat, it will start working. It is based on the average temperature of the environment where the Room Thermostat is located in the last 40 seconds. If the ambient temperature rises above the hysteresis positive temperature you set, your Room Thermostat turns off the heating unit, and if it drops below hysteresis negative temperature value, it turns on the heating unit. Thus, it is ensured that the ambient temperature remains within a certain range.
If the floor sensor measures temperature above 28°C, it turns off the heating unit.
External floor sensor is only active when it is connected.

GENERAL-LIFE-FH251S-Underfloor-Heating-Thermostat-
\(14\)

ROOM THERMOSTAT WIRING DIAGRAM

GENERAL-LIFE-FH251S-Underfloor-Heating-Thermostat-
\(15\)

WIRING DIAGRAM FOR ACTUATORS

WIRING DIAGRAM FOR WIRING CENTER

GENERAL-LIFE-FH251S-Underfloor-Heating-Thermostat-
\(17\) WARNING!
Operating related to the control panel, heating unit or electrical installation must be carried out by persons with professional qualifications.

DECLARATION OF CONFORMITY

ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.

  • Brand : GENERAL Life
  • Product Name : FH251S
  • Product Type  : Floor Heating Room Thermostat

Compatible Directives:
Electromagnetic Compatibility Regulation 2014/30/EU
(EN 61000-6-1:2019, EN 61000-6-3:2021)

Low Voltage Directive 2014/35/EU (IEC 60730-2-9)
Additional Information: The mentioned product can be used with  boilers with on / off output and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval.

WARRANTY CONDITIONS

  1. The warranty period starts from the invoice date and warranted against manufacturing defects for 2 years.

  2. Devices and apparatus are delivered to the customer in working condition in our company. On-site commissioning is subject to a service fee.

  3.  The repair of the devices and apparatus covered by the warranty is carried out in our company factory and should send by contracted transportation company. In on-site services, the transportation and accommodation expenses of the service personnel belong to the customer. The shift fee during transportation is added to the service fee and collected in advance.

  4. The maintenance of devices and apparatus is done in our company. For the maintenance of the devices and apparatus, the round travel fares belongs to the customer.

  5. I n case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault, and it is reported with a report issued by our company.

  6. In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair of the devices and apparatus at full expense by the manufacturer, unless it’s higher than the product’s price.

  7. n the event that the faults of the devices and apparatus whose warranty period continues are determined as caused by the customer, all expenses would be belong to the customer.

  8. Customers should be aware of damages (if there is any) of product and warn manufacturer since the day warranty duration starts.If customer do not warn the manufacturer with knowledge of damage, the customer lose the rights of article 6.

  9. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty.

  10. Devices and their apparatus are out of warranty if they are beaten, broken or scratched by the customer.

  11. amages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty.

  12. Battery leakage and errors due to rust, oxidation and liquid contact by working in acidic / humid environments are not covered by the warranty.

  13. When the product is not used for a long period (more than 15 days), remove
    the batteries. Otherwise, malfunctions that will occur are out of warranty.

  14. Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. Customers can take a transportation insurance.

  15. Damages caused by mains voltage / faulty electrical installation are not covered by the warranty.

  16.  Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake etc.

  17. All of the devices and apparatuses, including all their parts, are under the warranty of our company.

  18. I n case of malfunction of the devices and apparatuses within the warranty period, the time spent during repairment period is added to the warranty period. The repair period of the product cannot exceed 20 working days. This period starts from the date of notification to the service station of the malfunction related to the product or, in the absence of a service station, to the seller, dealer, agency, representative, importer or manufacturer of the product. Consumer can report the problem by; phone, fax, e-mail, registered and reply paid letter or a similar way. However,in case of a conflict , responsibility of prove is belong to the customer. If the malfunction of the product is not repaired within 20 working days, the manufacturer-producer or importer; has to allocate another product with similar features to the use of the consumer until the repair of the product is completed.

  19.  Although the consumer uses his/her repair rights, -I f the product breaks down for 4 times in a year or 6 times in warranty duration and these problems effects main purpose of the product.
    (starting from delivery time during warranty.)

    • Exceeding the maximum time required for repair,
    • In the event that the service station is not available, if it is determined that the repair of the defect is not possible with the report prepared (in order) by one of the seller, dealer, agency, representative, importer or manufacturer, a refund or a price discount at the rate of defect can be requested.
  20.  The customer can make complaints and appeals to consumer courts or consumer arbitration committees.

  21.  The warranty document must be kept by the customer during the warranty period. If the document is lost, a second document will not be issued. In case of loss, repair and replacement of devices and apparatus will be made for a fee.

WARRANTY CERTIFICATE

Manufacturer
Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Adress: Fatih Mah. 1188 Sk. No:13/A Sarnıç

Gaziemir İzmir-TÜRKİYE Tel: +90 (232) 457 99 50 Fax: +90 (232) 457 91 22
E-mail: generallife@generallife.com.tr Authorized Signature:
Company Stamp:

  • Product
  • Type: Floor Heating Room Thermostat Brand: GENERAL Life
  • Model: FH251S
  • Warranty Period: 2 Years
  • Max. Time to Repair: 20 Days Bandrol and Serial Number:

GENERAL-LIFE-FH251S-Underfloor-Heating-Thermostat-
\(1\)ISIPARK reserves the rights of changing product specifications and user manuals.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals