Datek 0ZAB-EU Contact Switch Instruction Manual
- June 1, 2024
- datek
Table of Contents
- Datek 0ZAB-EU Contact Switch
- Product Usage Instructions
- Introduction
- Installation
- Pairing Contact Switch to the Hub/Gateway
- Factory Reset
- LED indications
- Using the button
- Important safety information
- In the box
- Appendix
- Technical specifications
- Declaration of Conformity
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Datek 0ZAB-EU Contact Switch
Product Specifications:
- Brand: Datek
- Product Name: Contact Switch
- Functionality: Door/window sensor
- Installation: Battery-operated, app-controlled
- Placement: Door or window frames
- Indicator: LED lights for status indication
Product Usage Instructions
Installation:
- Loosen the docking to access the battery.
- Remove the battery tab from the device.
- Follow further installation steps in the Eva Smart Home app.
Pairing Contact Switch to the Hub/Gateway:
Go into the Eva Smart Home app and follow the instructions provided to pair
the Contact Switch to the hub or gateway.
Factory Reset:
- Press and hold the function button on the Contact Switch for more than 10 seconds to reset it to factory settings.
- The LED lights will flash green three times with a brief pause to indicate pairing mode/reset.
Placement of the Datek Contact Switch:
- Attach the sensor to door or window frames using double-sided tape. Ensure correct open/close status is displayed in the app and LED light indicates properly.
- Make sure sensor and magnet distance is less than 15mm for proper alignment.
LED Indications:
- LED OFF: Normal operation
- 1 short red flash: Sensor is open
- 2 short green flashes: User-initiated short poll
- 3 quick green flashes: Pairing mode
- 1 second green flash ON/OFF: Device startup
Using the Button:
- Hold button for more than 10 seconds: Factory reset
- Hold button for more than 6 seconds: Turn off flashing during opening/closing
- Hold button for more than 2 seconds: Activate short poll in 2 minutes
- Short push and connected to the hub: Send IAS supervision
FAQ :
-
How do I reset the Contact Switch to factory settings?
To reset the Contact Switch, press and hold the function button for more than 10 seconds until the LED flashes green three times with a brief pause. -
What is the recommended distance between the sensor and magnet?
The recommended distance between the sensor and magnet is less than 15mm for proper alignment and functionality.
Datek Contact Switch
Introduction
Datek Contact Switch ensures that you always have control over your home! It is small and location friendly. You attach the sensor to the door or to your window with double-sided tape. You get a full overview in the app of doors and windows.
Installation
- Loosen the docking by pushing on it to access the battery.
- Remove the battery tab from the device (see the illustration).
- Follow the further steps in the Eva Smart Home app.
Pairing Contact Switch to the Hub/Gateway
Go into the Eva Smart Home app and follow the instructions
Factory Reset
Press and hold the function button on the Contact Switch for more than 10
seconds to reset it to factory settings and put it in pairing mode
Note: LED lights will repeat 3 green flashes with a brief pause to
indicate that the device is in pairing mode/reset.
Placement of the Datek Contact Switch
- You can place the door/window sensor in door or window frames and secure it using double-sided tape.
- Note: Before attaching the Contact Switch, ensure that the device displays the correct open/close status with a red LED light and shows the correct status in the smart home app.
- Note: Make sure the sensor is mounted in such a way that the distance between the sensor and magnet is less than 15 mm. Both parts have markings to assist with proper alignment with each other.
LED indications
LED PATTERN | EXPLANATION |
---|---|
LED is OFF (normal) | During normal operation, the LED lights will be off |
1 short red flash | The sensor is opened (only if the LED light is activated) |
2 short green flashes | User initiated short poll |
Repetitive: 3 quick green flash and pause | LED light flashes 3 short green |
flashes every second to indicate that the sensor is in pairing mode
1 second green flash ON/OFF| Identify
---|---
Red and green alternately| The device starting up
Using the button
If the function button is held in:
More than 10 seconds| Factory reset
More than 6 seconds| Turn off flashing during opening/closing
More than 2 seconds| Activate “Short poll” in 2 minutes
Short push and connected to the hub| Send “IAS supervision”
Important safety information
- For indoor use only
- Can be used in temperatures ranging from 0 ºC to 40 ºC.
- This product is not a toy, keep out of reach of children.
- Do not place near any heating source or in direct sunlight, as this may cause overheating.
- Only use correct type of batteries. Risk of fire or explosion, if the battery is replaced by an incorrect type.
- Do not use the equipment in case of any visible damage.
- Dispose of used batteries according to instructions.
In the box
- Datek Contact Switch
- CR2 battery
- Reset key/stick
Appendix
Information on disposal for users of waste electrical & electronic equipment
- This symbol on the product and accompanying documents means that used electrical and electronic equipment (WEEE) should not be mixed with general household waste.
- For proper treatment, recovery and recycling, please take this product to designated collection points where it will be accepted free of charge. Alternatively, in some countries, you may be able to return your products to your local retailer upon purchase of an equivalent new product.
- Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please contact your local authority for further details of your nearest designated collection point. Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation.
Software updates
Software updates can be released by the manufacturer to fix bugs or enhance
functionality after the product has been released. Updated software versions
released will not impact continued compliance with applicable rules.
Technical specifications
General | IP Class: IP 50 (indoor) |
---|---|
Local Communication |
- Radio protocol: Zigbee 3.0
- Frequency: 2400-2483,5 MHz (IEEE 802.15.4)
Ratings|
- Operating temperature: 0 to +40 °C
- Operating voltage: 3V
Battery| CR2
Dimensions|
- Detector: 72x25x21 mm
- Magnet: 35x11x13 mm
Declaration of Conformity
Datek Smart Home AS declares that the equipment described in this document, is in compliance with the essential requirements and other relevant provisions of EU Directive 2014/53/EU. If you require a copy of the original signed DoC, please visit https://hjelp.evasmart.no/hc/no or scan QR code that can be found on the packaging of this product and select documents for your product.
Datek Smart Home AS l www.evasmart.no l +47 913 94
604
Subject to change without notice 2023-11-02_v1
Read User Manual Online (PDF format)