EXTOL LIGHT 43281 Dual Reflector LED Light User Manual
- June 3, 2024
- EXTOL LIGHT
Table of Contents
43281 Dual Reflector LED Light
User Manual
43281 (2 × 800 lm)
43283 (2 × 2400 lm)
Introduction
Dear customer,
Thank you for the confidence you have shown in the Extol® brand by purchasing
this product.
This product has been tested for reliability, safety, and quality according to
the prescribed norms and regulations of the European Union.
Contact our customer and consulting center for any questions at:
www.extol.eu
service@madalbal.cz
Manufacturer: Madal Bal a. s., Průmyslová zóna Příluky 244, 76001 Zlín, Czech
Republic
Date of issue: 20/03/2019
Description – The purpose of use
- Double LED floodlights Extol® Light 43281 (2 x 800 lm) and Extol® Light 43283 (2 x 2400 lm) with a single common power cord are intended for installation on a portable stand with a carry handle (fig. 1), which can, likewise, be installed on a telescopic tripod with adjustable height and arbitrary swivel around their 360° turning axes (fig. 2). The floodlights can be swiveled individually on the portable stand as required for illuminating a specific area (fig. 1). Each floodlight is equipped with an independent power switch, so one can use either just a single floodlight or both at the same time. As they are both waterproof and dust-proof, they can be used outdoors (however, the power connection must be protected).
- The Extol® Light 43283 LED floodlight is a 3× stronger source of light (2× 2400 lm) than model Extol® Light 43281 (2× 800 lm).
Technical specifications
Model/order number | 43281 | 43283 |
---|---|---|
Power input | 2× 10 W | 2× 30 W |
Luminous flux | 2× 800 lm | 2× 2400 lm |
Input voltage/frequency | 85-240 V/50~60 Hz | 85-240 V/50~60 Hz |
Length of the power cord | 293 cm | 293 cm |
Operating temperature | -35 °C to +45 °C | -35 °C to +45 °C |
IP of floodlight *) | 65 | 65 |
Swivel angle of stand on a tripod | 360° | 360° |
Dimensions of a single floodlight without handle (W×H×D) | 11.5 × 8.6 × 9.4 cm |
22.2 × 18.2 × 11 cm
Weight of one floodlight without cable| 0.6 kg| 1.5 kg
Weight of the complete set with a tripod without cable| 3,4 kg| 5.6 kg
*) The IP65 protection of the floodlight provides dust resistance and protection against rain and snow. For the safe operation of the floodlight, it is essential to provide the same level of protection for the floodlight‘s connection to the power source.
DIMENSIONS OF THE EXTOL® LIGHT 43281 AND EXTOL® LIGHT 43283 FLOODLIGHTS
INFORMATION REGARDING LED FLOODLIGHT ECODESIGN ACCORDING
TO EUROPEAN COMMISSION DIRECTIVE (EU) 1194/2012.
Floodlight parameters | 43281 | 43283 |
---|---|---|
Power efficiency class of the light source | A+ | |
2x 10.02 kWh/1000h | A+ |
2x 30.01 kWh/1000h
Light source socket| X| X
Power input, power voltage, and frequency| 2x 10W
85-240 V/50-60 Hz| 2x 30W
85-240 V/50-60 Hz
Equivalent to power draw of a standard light bulb| 2x 60 W| 2x 150 W
Rated luminous flux:| 2x 8001m| 2x 24001m
Luminosity| 2x —120 cd| 2× ~300 cd
Rated lifespan of the light source| > 30 000 hours| > 30 000 hours
Power factor of the light source| 0.8| ≥ 0.9
Aging factor of the light source at 6000 h| 0.80| ≥ 0.80
Start-up time| 0.1 s| 0.1 s
Warm-up time for 60% of full luminous flux| 0.1 s| 0.1 s
Color rendering Ra| ?. 65| > 65
---|---|---
Colour chromaticity (color temperature)| 6300 K| 6300 K
Colour retention| < 6| < 6
Wavelength| 500-600 nm| 500-600 nm
The angle of light emission into space| > 120°| > 120°
Highlighting light source| X| X
Dimmability of the light source| X| X
Number of switch cycles to malfunction| 15000x| 15000x
For outdoor use| ✓IP 65| ✓IP 65
Dimensions of the floodlight| 85 x 265 x 115 mm| 222 x 182 x 11 mm
Mercury content in the light source| 0.0 mg| 0.0 mg
ENERGY LABEL OF THE FLOODLIGHT
- This lighting device contains a built-in LED light source.
- The light source in this lighting device cannot be replaced.
Connection and installation of the floodlight
ATTENTION
- Carefully read the entire user‘s manual before first use and keep it with the product so that the user can become acquainted with it. If you lend or sell the product to somebody, include this user‘s manual with it. Prevent this user‘s manual from being damaged. The manufacturer takes no responsibility for damages or injuries arising from the use of the device that is in contradiction to this user‘s manual. Acquaint yourself with all the control elements and parts of the floodlight before using it. Check that all parts are firmly attached before use, also check that no part of the floodlight is damaged, namely the protective front cover and the insulation on the power cord. A degraded power cord is also considered to constitute damage. Do not use a floodlight with damaged parts and have it repaired at an authorized service center for the Extol® brand.
INSTALLATION OF THE FLOODLIGHTS AND TRIPOD
-
Mount the floodlights and secure them in place with the supplied screws to the portable stand with carrying handle, see fig. 1 and point them as required. The floodlights can be used in this way, installed on a stand and carried using the carry handle or the given stand can be installed and attached to a telescopic tripod. Assemble the tripod according to fig. 2 and secure all its moving parts using the relevant fastening elements.
The extended tripod rod can be turned 360° around its central axis as required, see fig. 2.
The direct distance of the floodlights from the illuminated object should be at least 0.5 m, see fig. 6. -
If necessary, the floodlights may be mounted on a wall. Mount the floodlight at a height of 1-3 m above the ground (fig. 6). The direct distance of the floodlights from the illuminated object should be at least 0.5 m. When the floodlight is mounted in a corner then it must be at least 20 cm away from the ceiling (Fig. 7).
• ATTENTION
- Protect the power cord of the floodlight against thermal and mechanical damage. In the event of damage, immediately turn off the floodlight, disengage the voltage in the grid and organize a repair at an authorized service center for the Extol® brand.
- For safety reasons, do not cover the floodlight during operation; circulation of ambient air must be provided for. Likewise, do not install or operate the floodlight in a confined small area with an insufficient volume and circulation of air.
- The floodlight has a non-replaceable light source, which when not mechanically damaged has a lifespan of more than 30,000 hours, and thus under normal circumstances, it is not necessary to remove the floodlight‘s front cover.
CONNECTING TO A POWER SOURCE AND TURNING ON
- WARNING y The floodlight is connected to the power supply by means of a power cord with a standard plug intended for 230 V ~50 Hz sockets.
- The floodlight can be connected to a voltage in the range specified in the chapter with the technical specifications. Prior to connecting the floodlight, check that the above-specified voltage is in the grid.
- The floodlight must be connected to a power socket with its circuit protected by a residual current device (RCD) with a breaking current of 30 mA. y If the connection (power cord) of the floodlight is repaired in any way with respect to the specific connection requirements, all modifications and connections must be performed by a person with electrical qualifications (i.e. a knowledgeable person) according to current norms EN 50110-1, IEC 60050-195 and EN 501102 and EN 61140. In the event of any modifications to the power cord leading to the floodlight and its connection, the manufacturer cannot bear any responsibility for non-professional work.
ATTENTION
- The connection of the floodlight to the el. the power source must be permanently protected against the entry of water, high moisture or snowfall, or thermal and mechanical damage. The IP 65 protection level of the floodlight does not apply to the floodlight‘s connection to the power source when the same level of protection is not provided!
- Do not locate the floodlight on a flammable surface. The floodlight must not be used in an environment where there is a risk of fire or explosion.
- Always use the floodlight with an undamaged protective front cover that prevents damage to the LED diodes and its exposure to humidity/ water and dust. In the event that the floodlight or power cord is damaged, immediately turn off the power source, disconnect the floodlight and replace it with an undamaged unit.
TURNING ON
- Each floodlight is equipped with an on/off switch, so one can use both floodlights at the same time or just one.
Cleaning, maintenance, and repairs
- In the event that the floodlight requires cleaning, first unplug it from the el. power supply and allow it to cool down. Do not use abrasive cleaning products and organic solvents to clean the floodlight as this would damage it.
- Service adjustment or installation of the floodlight must be performed with the power supply disconnected.
- In the event that the power cord itself is damaged, immediately disconnect it from the power cord without voltage in the grid and have it replaced at an authorized service center for the Extol® brand.
- In the event of damage to the protective front cover of the floodlight, replace it with a new one. For safety reasons, it is not possible to use the floodlight with a damaged protective front cover. If the user replaces the protective front glass, the manufacturer can no longer guarantee the IP65 protection class with protection against the damaging entry of water and dust because the manufacturer cannot be responsible for the possible incorrect installation of the protective front cover by the user. When the protective cover is replaced, the same level of protection must be ensured as in the original configuration. The original gasket seal from the manufacturer must be used. When the glass is replaced, the gasket seal must be completely undamaged and untwisted. The glass must have the same thickness as the original. In the event that these requirements are not met, the provided level of protection will be insufficient against the entry of water and dust, and the floodlight must not be exposed to rain, moisture, or another form of water entry and dangerous touching.
- For warranty repairs, please contact the vendor from whom you purchased the product and they will organize repairs at an authorized service center for the Extol® brand. For a post-warranty repair, please contact the authorized service center of the Extol® brand directly (you will find the repair locations at the website at the start of this user‘s manual).
References to the label and pictograms
| Meets respective EU requirements.
---|---
| The minimum clearance between the lighting device and the illuminated item
must be 0.5 m.
| Only use the floodlight with the undamaged front cover installed.
| Do not use a floodlight with a damaged front cover, and replace it with a
new one.
| Highest nominal ambient temperature.
| Do not place the lighting device in the vicinity of easily flammable
materials and on easily flammable materials. Do not use in an environment
where there is a risk of explosion or fire.
| Non-dimming light source.
| Read the user’s manual before use.
| Do not dispose of unserviceable commodities in household waste, but dispose
of/recycle them in an environmentally safe manner.
Waste disposal
- Throw packaging materials into a container for the respective sorted waste.
- The product contains electronic components that constitute a hazardous waste. According to European Directive No. 2012/19 EU, electric appliances must not be thrown out with household waste and must be handed over for ecological disposal at specified collection points. You can find information about these collection points at your local town council office.
EU Declaration of Conformity
Subjects of declaration – models, product identification:
Extol ® Light 43283
Extol ® Light 43281
LED floodlights on a tripod
Manufacturer Madal Bal a.s. • Bartošova 40/3, CZ-760 01 Zlín • Company ID No.:
49433717 hereby declares that the described products listed above are in
conformity with relevant harmonization legal regulations of the European
Union: (EU) 2011/65; (EU) 2014/30; (EU) 2014/35; (EU) 1194/2012
This declaration is issued under the exclusive responsibility of the
manufacturer.
Harmonization norms (including their amendments, if any exist), which were
used in the assessment of conformity and on the basis of which the Declaration
of conformity is issued:
EN 60598-1:2015; EN 60598-2-5:2015; EN 60598-2-4:1997; EN 62493:2015;
EN 62471:2008; EN 55015:2013; EN 61547:2009; EN 61000-3-2:2014; EN
61000-3-3:2013; EN 50581:2012
Place and date of issue of EU Declaration of Conformity: Zlín 20.3.2019
On behalf of Madal Bal, a.s.
Martin Šenkýř