Schneider Electric Acti9 Combi Surge protector Instruction Manual

June 4, 2024
Schneider Electric

Schneider Electric Acti9 Combi Surge protector

Schneider Electric Acti9 Combi Surge protector-pro

PLEASE NOTE

  • The installation, maintenance, and eventual replacement of this device must only be carried out by a qualified electrician.
  • This device must not be repaired.
  • All applicable local, regional and national regulations must be complied with during the installation, use, maintenance, and replacement of this device.
  • This device should not be installed if, when unpacking it, you observe that is damaged.
  • Schneider Electric cannot be held responsible in the event of non-compliance with the instructions in this document and in the documents to which it refers.
  • The service instruction must be observed throughout the product life time of this device.

Description

Schneider Electric Acti9 Combi Surge protector-1

  1. End-of-life indicator:
    • Green: ok
    • Red: end of life
  2. Overvoltage indication:
    • White: no overvoltage
    • Red: overvoltage detected
  3. Earth terminal

Connection

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

  • Turn off all power supplying this device before working on it.
  • Use a voltage tester with a suitable rated voltage in order to check that all active conductors aren’t energized.
    Failure to follow these instructions will result in death or serious injury

Schneider Electric Acti9 Combi Surge protector-2

3PN| Cable cross-section for flexible and rigid cables in mm²| Tightening torque (N.m)
---|---|---
Product Reference /| Designation /| L1 / L2 / L3| N| PE| L1 / L2 / L3| N| PE
A9L20716| Acti9 Combi SPU 3P+N C curve 16A SPD|  |  | Rigid cables: 4…35 mm²

Flexible cables: 4…25 mm²

| 2.5| 2.5| 3.5
A9L20720| Acti9 Combi SPU 3P+N C curve 20A SPD|  |  | 2.5| 2.5| 3.5
| | Rigid cables:6…25 mm²| Rigid cables:6…25 mm²

A9L20725| Acti9 Combi SPU 3P+N C curve 25A SPD| 2.5| 2.5| 3.5
 |  | |
A9L20732| Acti9 Combi SPU 3P+N C curve 32A SPD| 3.5| 3.5| 3.5
| | Flexible cables: 6…16 mm²| Flexible cables:6…16 mm²
A9L20740| Acti9 Combi SPU 3P+N C curve 40A SPD| 3.5| 3.5| 3.5
| | |
A9L20750| Acti9 Combi SPU 3P+N C curve 50A SPD| 3.5| 3.5| 3.5
A9L20763| Acti9 Combi SPU 3P+N C curve 63A SPD| | | 3.5| 3.5| 3.5

End of life

Schneider Electric Acti9 Combi Surge protector-3

Schneider Electric Industries SAS
35, rue Joseph Monier
CS 30323
F – 92506 Rueil Malmaison Cedex
www.se.com
GDE9796206-02

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals