WARNING AND GUIDELINES!!!
Read and follow all safety instructions!!
DO NOT INSTALL DAMAGED PRODUCT! This product has been properly packed so that
no parts should have been damaged during transit. Inspect to confirm. Any part
damaged or broken during or after assembly should be replaced.
WARNING : TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE WIRING
WARNING: Risk of Product Damage
Electrostatic Discharge (ESD): ESD can damage product(s). Personal grounding
equipment should be worn during all installation or servicing of the unit
Do not stretch or use cable sets that are too short or are of insufficient
length
Do not modify the product
Do not mount near gas or electric heater
Do not change or alter internal wiring or installation circuitry
Do not use product for anything other than its intended use
WARNING – Risk of Electric Shock
Verify that supply voltage is correct by comparing it with the product
information
Make all electrical and grounded connections in accordance with the National
Electrical Code (NEC) and any applicable local code requirements
All wiring connections should be capped with UL approved recognized wire
connectors
All unused wiring must be capped
PRODUCT OVERVIEW
Cyrus AM is a BLE5.2 controllable high bay Microwave motion and daylight sensor. This sensor operates on a 90-277VAC input voltage range adopts a 5.8GHz Microwave sensing technology for accurate motion detection. It can be mounted at a maximum height of 12m(39.4ft) and provides a maximum detection range of 17m(55.8ft) diameter. The sensor can be mounted to the ceiling or at the surface using ceiling or surface mount accessories. It can be quickly commissioned, configured, and controlled from any mobile device and can be connected to Lumos Controls cloud for data analytics and configuration management
Do’s | Dont’s |
---|---|
Installation should be performed by a qualified electrician | Don’t use outdoors |
Installation shall be in accordance with all applicable local and NEC codes |
Avoid input voltage exceeding
maximum rating
Turn the power OFF at circuit breakers before wiring| Don’t disassemble the
products
Observe the correct polarity of output terminal|
Specifications| Value| Remarks
---|---|---
Input voltage| 90-277VAC| Rated input voltage
Input current| 9mA@230VAC 1SmA@9OVAC| –
Inrush current| 4A|
Surge rating| 4kV|
Operating temperature| 0-80°C (32 to 176W)| –
Dimensions
(Excludes accessories)| 23 x 2.Sin
(59.8 X 63.1mm)| Diameter x Height
Net weight
(Excludes accessories)| 85g (3.0oz)| In grams
Case temperature| 70°C (158°F)| _
Case material| ABS Plastic| White
Dimensions
(Ceiling mount accessories)
WMAM-CMK| 3.53 x 2.62in (89.7 x 668mm)| Diameter x Height
Dimensions
(Surface mount accessories)
WMAM-SMK| 4.32 x 2.80In (109.8 x 71.2mm)| Diameter x Height
REQUIRED TOOLS & SUPPLIES
INSTALLATION INSTRUCTIONS
Wiring the sensor
Turn off the power before wiring and installing the device
Power the sensor by connecting the AC Line and Neutral wires from the mains
supply to the Line (Black color), and Neutral (White color) from the sensor.
CEILING MOUNT
Mounting sensor on false ceiling
Ceiling mount: Sensor can be installed in the false ceiling using the flush
mounted accessory, such as the clips, as given in the steps below
-
Make a hole of 78mm diameter in the false ceiling where the sensor is to be installed and take out the main supply wires
-
Connect the Line (Black) and Neutral (White) wires from the device with the external mains supply wires using wire connectors and terminate the same inside the junction box.
-
Press and hold the spring clips (on both sides of the device) and insert the sensor into the mounting hole. Release the spring clips so that the sensor will fit in and remain intact.
Note
To remove the sensor from the ceiling, hold and pull the sensor down
Removing Lens
Rotate the lens clockwise to connect to the case and rotate anti-clockwise to
dismantle from the case
SURFACE MOUNT
Mounting sensor on false ceiling
-
Position the sensor mounting base to fix and take out the mains wire through the hole given at the mounting base.
-
Mount the base on the selected position using screws
Head: CSK Slotted -
To power the sensor, connect the AC Line and Neutral wires from the mains supply to the sensor Line (Black) and Neutral (White) wires using wire connector. Terminate the wires within the sensor mount.
-
Connect the sensor unit case with the Mount base (that is already fixed in step 2) by rotating the case clockwise.
Note
To remove the sensor unit case from the mount base, apply pressure towards
ceiling and rotate the sensor case anti-clockwise.
WIRING DIAGRAM
APPLICATION
TROUBLESHOOTING
Lights are not responding to Motion| Check whether the Sensor is powered ON
Check whether the Sensor association configured in the Group is correct
---|---
Lights are not responding to Daylight| Check whether the Sensor is powered ON
Check whether the Sensor association configured in the Group is correct
Check whether the Daylight Sensor Settings (for the Sensor displayed under
Devices tab) configured is correct
WARRANTY
5-year limited warranty
Please find warranty terms and conditions
Note: Specifications may change without notice
Actual performance can vary due to end-user environment and application
COMMISSIONING
Once powered up, the device will be ready to be commissioned via the Lumos
Controls mobile app, available for free download on iOS and Android. To begin
commissioning, click the ‘+’ icon from the top of the ‘Devices’ tab. The app
allows you to preset certain configurations which will be loaded after the
device is added. The pre-configurations made using ‘Commissioning Settings’
will be sent to the devices being commissioned.
Once commissioned, the device will be displayed in the ‘Devices’ tab and you
can configure Sensitivity from the device settings.
https://knowledgebase.lumoscontrols.com/knowledge
Please visit Help center for more details
LUMOS CONTROLS APPLICATION
Download the ‘Lumos Controls’ application from Play Store or App Store OR Scan
the QR codes to download the ‘Lumos Controls’ application
https://play.google.com/store/apps/details?id=com.wisilica.Home&hl=en_IN&gl=US
https://apps.apple.com/us/app/wisilica-lighting/id1098573526
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by WiSilica Inc. is under license. Other trademarks and trade names are those of their respective owners.
www.lumoscontrols.com
20321 Lake Forest Dr D6,
Lake Forest, CA 92630
+1 949-397-9330
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>