Tenda TEG1005D 16 Port Gigabit Ethernet Switch Installation Guide

June 1, 2024
Tenda

Quick Installation Guide
5/8/16-Port Gigabit Ethernet Switch

TEG1005D 16 Port Gigabit Ethernet Switch

  • TEG1005D/TEG1008M/TEG1016M
    9-Port 10/100M Ethernet Desktop Switch

  • TEF1109D
    5-Port Fast Ethernet Switch

  • TEF1005D

Package contents

TEG1005D/TEF1005D/TEG1008M/TEF1109D

  • Switch * 1
  • Power adapter * 1
  • Quick installation guide

TEG1IO16M

  • Switch * 1
  • Power adapter * 1
  • Screw (Thread diameter: 3 mm, length: 14 mm) * 2
  • Expansion bolt (height: 6.6 mm, inner diameter: 2.4 mm, length: 26.4mm) * 2
  • Quick installation guide

TEF1109D is used for illustrations here unless otherwise specified.
The actual product prevails.

LED indicators

LED indicator Status Description

Power/
TEG1016M:
on the rear panel| Solid on| Powered on
Off| Powered off
1-5/8/9/16| Solid on| Connected but not active
Blinking| Data transmitting
Off| Not connected

Working mode toggle
(TEF1109D/TEG1016M)

Working mode Description
VLAN off Default mode. In this mode, all ports can communicate with each

other.
VLAN on| In this mode, the downlink ports on a switch are isolated from each other, but can communicate with the uplink port.
This mode helps isolate DHCP broadcast and reduce broadcast storm.
Uplink ports:
— TEG1016M: Port 15,16
— TEF1109D: Port 9
Downlink ports:
— TEG1016M: Ports 1-14
— TEF1109D: Ports 1-8

Install the device

◼ Preparations

  • Desktop mounting: ESD bracelet or gloves
  • Wall mounting: ESD bracelet or gloves, screwdriver, spirit level, marker, hammer drill, rubber hammer, ladder, 2 expansion bolts (self-prepared except TEG1016M, height: 6.6 mm, inner diameter: 2.4 mm, length: 26.4mm) and 2 screws (self-prepared except TEG1016M, thread diameter: 3 mm, length: 14 mm,head diameter: 5.2 mm)
  • Desktop mounting
    TEG1005D/TEF1005D/TEG1008M/TEF1109D
    Horizontally place the switch right-side up on a big enough, clean, stable and flat desktop.
    TEG1016M
    Paste the four footpads to the four recesses on the bottom of the switch.
    Then turn the switch upside down, and place it horizontally on a big enough, clean, stable and flat desktop.

◼ Wall mounting
Note

  • This switch can only be installed on non-flammable walls, such as a concrete wall.
  • Do NOT install the switch with its air vents facing downward. Otherwise, there will be potential safety hazards.
  1. Use a hammer drill to drill 2 holes (diameter: 6 mm) on the wall and the distance between the 2 holes is (TEG1008M/TEF1109D: 116mm, TEG1005D/TEF1005D: 80 mm, TEG1016M:110mm). Keep the two holes on a horizontal line.
  2. Knock the expansion bolts into the holes using a rubber hammer. Use a screwdriver to fix the screws into the expansion bolts. The distance between the inside surface of the screw header and the edge of the expansion bolt should not be less than 2.5 mm, to make sure that the switch can be hung on the screws firmly.
  3. Align the two wall-mounting slots on the bottom of the switch with the two screws on the wall, and then slide the switch to fit in the screws until it is firmly hung on the screws.

Tenda TEG1005D 16 Port Gigabit Ethernet Switch -
Diameter

Typical network topologies

  Tips
The switch supports auto MDI/MDIX. You can use either a straight through cable or a crossover cable to connect the switch to Ethemet devices.
Standard mode (default)
Tenda TEG1005D 16 Port Gigabit Ethernet Switch - Power VLAN mode
Tips
Only TEG1016M and TEF1109D support VLAN mode, this mode is VLAN on.Tenda
TEG1005D 16 Port Gigabit Ethernet Switch - WNT port

Get support and services

For technical specifications, user guides and more information, please visit the product page or service page on www.tendacn.com. Multiple languages are available.
You can see the product name and model on the product label.

https://www.tendacn.com/service/default.html

FAQ

Q1. The Power or LED indicator does not light up. What should | do?

- Ensure that the power adapter is connected to the switch and the power jack properly. - Ensure that the power jack is powered on. - Ensure that the input voltage matches the value required by the switch.

Q2: When the Link/Act LED indicator (1-5/8/9/16) of the switch is off. What should | do?

- Ensure that the Ethemet cable between the switch and the attached device is connected properly, and the length of the Ethernet cable is within standard length 100m. - Ensure that the switch is powered on. - Ensure the connected device is powered on and working properly.

Safety Precautions

Before performing an operation, read the operation instructions and precautions to be taken, and follow them to prevent accidents. The warning and danger items in other documents do not cover all the safety precautions that must be followed.
They are only supplementary information, and the installation and maintenance personnel need to understand the basic safety precautions to be taken.

  • For desktop mounting, the device must be horizontally mounted for safe use.
  • For wall mounting, the device is only suitable for mounting at heights = 2 m.
  • Operating environment: Temperature: 0 C – 40 C; Humidity: (10% – 90%) RH, non-condensing; Storage environment: Temperature: -40 C – 70 C; Humidity: (5% – 90%) RH, non-condensing.
  • Clean only with dry cloth.
  • Do not biock any ventilation openings using things such as newspapers, table-cloth, curtains.
  • Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus that produce heat.
  • If the device has a grounding terminal, connect the grounding terminal of the switch to a grounding table to protect your switch from lightning damage.
  • Do not damage the ground conductor or operate the device in the absence of weill-installed ground conductor. Conduct the appropriate electrical inspection. Refer to the Lightning Protection Guide at the official website for instructions.
  • Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles and at the point where they exit from the device.
  • Only use attachments/accessories specified by the manufacturer.
  • Unplug this device during lightning storms or when unused for long periods of time.
  • The mains plug is used as the disconnect device and shall remain readily operable.
  • Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, for example, power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the device, the device has been exposed to rain or moisture, does not work normally, or has been dropped.
  • Warning: To reduce the risk of fire or electric shock, do not expose this device to rain or moisture. The device shall not be exposed to dripping or splashing.
  • Warning: To reduce the risk of electric shock, do not remove the cover as there are no user-serviceable parts inside. Refer servicing to qualified personnel.

For latest safety precautions, see Safety and Regulatory Information on www.tendacn.com .

**** CE Mark Warning

(TEG1016M/TEG1008M/TEF1109D) This is a Class A product.
(TEG1005D/TEF1005D)} This is a Class B product.
In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
NOTE: (1) The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. (2) To avoid unnecessary radiation interference, it is recommended to use a shielded RJ45 cable.
Declaration of Conformity
Hereby, SHENZHEN TENDA TECHNOLOGY CO., LTD. declares that the device is in compliance with directives 2014/35/EU and 2014/30/EU.
The full text of the EU declaration of conformity is available at the following internet address:  https://Awww.tendacn.com/download/list-9.html

FCC Statement
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Caution!
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: (1) The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. (2) To avoid unnecessary radiation interference, it is recommended to use a shielded RJ45 cable.
(TEG1016M/TEG1008M/TEF1II09D)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

(TEG1005D/TEF1005SD)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Comnect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

RECYCLING

This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment. User has the choice to give his product to a competent recycling organization or to the retailer when he buys a new electrical or electronic equipment.

Copyright
Copyright © 2023 Shenzhen Tenda Technology Co., Ltd. All rights reserved.
Tenda is a registered trademark legally held by Shenzhen Tenda Technology Co., Ltd.
Other brand and product names mentioned herein are trademarks or registered trademarks of their respective holders. Specifications are subject to change without notice.
Technical Support
Shenzhen Tenda Technology Co., Ltd.
Floor 6-8, Tower E3, No.1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052
Website: www.tendacn.com
E-mail: [email protected]
[email protected] (North America)
[email protected] (United Kingdom)
V1.1 Keep for future reference

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Tenda User Manuals

Related Manuals