EMKO SPL3P1-02-00-03-00_1 Module with Digital Input and Transistor Output User Guide

June 1, 2024
EMKO

EMKO SPL3P1-02-00-03-00_1 Module with Digital Input and Transistor Output

User Guide

Slim CPU (PLC) Module with Digital Input & Transistor Output

SPL3P1-02-00-03-00_1
SPP3P1-30-00-51-00_1

General Specifications

  • Program Memory Area : 196K
    Volatile Memory Area: 27K

  • 9 pieces Digital Input ( NPN / PNP)

  • 6 pieces Digital Output (Active High)

  • Ethernet 10/100 Mbit
    Easy access via the Internet with WEB QUICK CONNECT
    Module access via Web Browser with IPERTU SCADA

  • Modbus RTU communication protocol with RS232

  • Modbus RTU communication protocol with RS485

  • USB – Device (For device configuration)

  • Modular connection (up to 16 extension modules can be connected)

  • Led indicators:
    – RUN, USB, RS-485
    – Active Input led indicators
    – Active Output led indicators

Technical Specifications

Technical Specifications

Technical Specifications Continued

Volatile Memory Area Map

Volatile Memory Area Map

Volatile Memory Area Modbus Slave Addresses

Volatile Memory Area Modbus Slave Addresses

Specific Bit Memory Area Definitions

Specific Bit Memory Area Definitions

Specific Bit Memory Area Definitions Continued

Specific Data Memory Area Definitions

Specific Data Memory Area Definitions

Specific Data Memory Area Definitions Continued 1

Specific Data Memory Area Definitions Continued 2

Installation & Wiring

Installation and Wiring

* Do not connect AC Power to any I/O terminal, otherwise serious damage may occur in module. Please check all wiring prior to energizing device. In order to prevent electromagnetic interference, be sure the grounding made corrected. Connect ground terminal in the power input connector to the overall system ground. Don’t touch any terminals after energizing the device, in case of need to touch any terminal, de-energize the device before connection.

* For digital input connections; In case of using encoder, as fast counter, use the encoders original cables. Keep the cables away from power cables in order to prevent electrical interference. Ground the encoders screen cables to device ground.

* For Fast Digital Input counter (encoder) connections; For HSCO I0 = A, I1 = B; For HSC1 I3 = A, I4 = B and For HSC2 I6 = A, I7 = B

* For RS232 communication connection; Use shielded communication cable and ground the shield conncection to power input earth terminal.

* For RS485 communication connection; Connect the termination resistor (120R) between A & B terminal of the CPU (PLC) module, connected left of the extension module group. In case of more than one module group, connect it between the A & B terminals of the CPU (PLC) module, connected left of the extension module group, at the end of the communication line. Use shielded and twisted-pair communication cable. Ground the shield connection of the cable to power input earth terminal. 

Dimensions

Dimensions

Product Order Codes

Product Order Codes

ENG IPERTU-SPL_SPPXXX 02 V00_0323

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EMKO User Manuals

Related Manuals