EMKO ESM-4450 Process Controller Module System Instructions
- June 1, 2024
- EMKO
Table of Contents
EMKO ESM-4450 Process Controller Module System
Process Controller
ESM-4450 48 x 48 1/16 DIN Universal Input PID Process Controller with Smart I/O Module System
-
4 digits process (PV) and 4 digits process set (SV) display
-
Universal process input (TC, RTD, mV , V , mA )
-
Optional secondary sensor input
-
– Dual or multi-point calibration for voltage / Current input
-
– Configurable ON/OFF, P, PI, PD, and PID control forms
-
Adaptation of PID coefficients to the system with Auto-tune and
Self-tune -
Manual/Automatic mode selection for control outputs
-
Bumpless transfer
-
Smart I/O module system
-
Programmable heating, cooling, and alarm functions for control outputs
-
Motorized valve control function
-
8 steps profile control ( Ramp & Soak ) function and start-hold stop by using the logic input module
-
Remote set point function by using analog input modules
-
Retransmission of process value or process control by using 0/4…20 mA Current Output Module
-
Detection of heater failure by using 0…5A CT input module
-
Hardware configuration by using input/output modules
-
RS-232 (standard) or RS-485 (optional) serial communication with Modbus RTU protocol
Product Information
Specifications
- Model: ESM-4450
- Size: 48 x 48 mm
- Format: 1/16 DIN
- Input Type: Universal
- Features: PID Process Controller with Smart I/O Module System
Product Usage Instructions
Installation
- Ensure the power is switched off before installation.
- Mount the ESM-4450 unit securely in a suitable location.
- Connect the necessary input and output devices as per your process requirements.
Configuration
- Power on the ESM-4450 and access the configuration menu.
- Set the desired parameters such as setpoint, proportional band, and integral time.
- Save the configuration settings before exiting the menu.
Operation
- Monitor the process variables displayed on the ESM-4450 screen.
- Make adjustments to the controller settings if necessary to maintain optimal process control.
Frequently Asked Questions (FAQ)
Q: How do I reset the ESM-4450 to factory settings?
A: To reset to factory settings, navigate to the reset option in the
configuration menu and confirm the reset action.
Q: Can the ESM-4450 be used in both temperature and pressure control
applications?
A: Yes, the ESM-4450 with its universal input capability can be used for a
wide range of control applications including temperature and pressure control.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>