AIGOSTAR B0CLZCYWC2 12000 BTU Smart Portable Air Conditioner Instruction Manual
- June 14, 2024
- aigostar
Table of Contents
AIGOSTAR B0CLZCYWC2 12000 BTU Smart Portable Air Conditioner
IMPORTANT SAFETY INSTRUCTIONS
Thank you for choosing the luxurious and elegant mobile air conditioning. Please keep the manual for later review, and read the manual carefully before use.
Notes:
- The air conditioning is only suitable for indoor use and is not suitable for other applications.
- Follow local grid interconnection rules while installing the air conditioning and ensure that it is properly grounded. If you have any questions on electrical installation, follow the instructions of the manufacturer, and if necessary, ask a professional electrician to install it.
- Place the machine in a flat and dry place and keep a distance of above 50cm between the machine and the surrounding objects or walls.
- After the air conditioning is installed, ensure that the power plug is intact and firmly plugged into the power outlet, and place the power cord orderly to prevent someone from being tripped or pulling out the plug.
- Do not put any object into the air inlet and outlet of the air conditioning. Keep the air inlet and outlet free from obstructions.
- When drainage pipes are installed, ensure that the drainage pipes are properly connected, and are not distorted or bent.
- While adjusting the upper and lower wind-guide strips of the air outlet, pluck them with your hands gently to avoid damaging wind-guide strips.
- When moving the machine, make sure that it is in an upright position.
- The machine should stay away from gasoline, flammable gas, stoves, and other heat sources.
- Don’t disassemble, overhaul, and modify the machine arbitrarily, otherwise, it will cause a machine malfunction or even bring harm to persons and properties. To avoid danger, if a machine failure occurs, ask the manufacturer or professionals to repair it.
- Do not install and use the air conditioning in the bathroom or other humid environments.
- Do not pull the plug to turn off the machine.
- Do not place cups or other objects on the body to prevent water or other liquids from spilling into the air conditioning.
- Do not use insecticide sprays or other flammable substances near the air conditioning.
- Do not wipe or wash the air conditioning with chemical solvents such as gasoline and alcohol. When you need to clean the air conditioning, you must disconnect the power supply, and clean it with a half-wet soft cloth. If the machine is really dirty, scrub it with a mild detergent.
- The appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and maintenance shall not be done by children without supervision.
- Risk of fire or explosion. Flammable refrigerant used. To be repaired only by trained service personnel. Do not puncture refrigerant tubing.
- Risk of fire or explosion. Dispose of properly by federal or local regulations. Flammable refrigerant used
SPECIFICATIONS
- Model No: JHS-A018J-08KR-D (330700A5D)
- Power Supply: 115 V ~ 60 Hz
- Mean of Power Input: 1099 W
- Cooling Capacity: 12000 Btu/h
- Rated SACC: 8150 Btu/h
FEATURES AND COMPONENTS
Features
- New look, compact structure, streamlined machine, aristocratic atmosphere.
- With cooling, heating (single cold without heating function), dehumidification and fan function, and continuous water drainage functions.
- The automatic swing leaf in the outlet has an automatic air swing function, and the outlet can be covered when the machine is turned off to prevent dust from entering the body.
- LCDs the control panel. The machine is beautiful and elegant. A high-quality LCD remote control is equipped to facilitate operation.
- Handles on both sides adopt a dividing point design so that it is easier to carry it and the body design is more humane.
- The structure of wrapping the power cord on the back facilitates users to hang the power cord without hanging it down to the ground and staining and damaging the power cord.
- The outdoor interface is set high to facilitate assembly and keep the smooth flow of the heat pipe.
- Air filtration capability.
- Timing switch function.
- Protection function of automatically restarting the compressor after three minutes, with a variety of other protection functions
INSTALLATION AND ADJUSTMENT
Installation
Warning: before using the mobile air conditioning, keep it upright for at
least two hours. The air conditioning can be easily moved into the room. In
the moving process, ensure that the air conditioning is in the upright
position and the air conditioning should be placed on a flat surface. Do not
install and use the air conditioning in the bathroom or other humid
environments.
- Install the heat pipe assembly (as shown in Figure 1 ): screw the heat pipe assembly (exhaust fitting end) into the exhaust port on the rear panel (counterclockwise).
- Install the window sealing plate assembly
- Half-open the window, and mount the window sealing plate assembly to the window (as shown in Figure 2 and Figure 3); the assembly can be placed in the horizontal and vertical directions.
- Pull various components of the window sealing plate assembly open, adjust their opening distance to bring both ends of the assembly into contact with the window frame, and fix various components of the assembly.
- Install the body
- Move the machine with installed heat pipe and fittings before the window, and the distance between the body and walls or other objects shall be at least 20inch (as shown in Figure 4)
- Elongate the heat pipe and snap the flat end of the heat pipe joints into the elliptical hole of the window sealing plate assembly (as shown in Figure 5 and Figure 6).
Notes:
- The flat end of the heat pipe joints must be snapped into place.
- The pipe cannot be distorted nor has substantial turning (greater than 45 ° ). Keep the ventilation of the heat pipe unobstructed.
CONTROL SETTING
Operating instructions
- Power: Press the key to turn on and turn off the unit. HOLD 5 Sec for WiFi.
- Mode: In the case of power on, press this key to switch between cooling -+ fan -+ dry mode.
- Fan: In cooling and fan mode, press the key to select high, middle, and low fan speed. This function is not available in SLEEP mode and dehumidifying mode.
- Down: Press this button to decrease the temperature setting or set down the timer to the required timer setting. This function is not available under FAN mode and DEHUMIDIFYING mode.
- Up: Pressing this button to increase the temperature setting or set up the timer to the required timer setting. This function is not available under FAN mode and DEHUMIDIFYING mode.
- Timer: Press the TIMER button to set the unit to automatically turn ON or OFF. Use the + and – buttons to program the hour increment.
- Sleep: In cooling mode, press the sleep button to turn on the sleep mode, then the unit will work < on Energy-Saving and quiet mode. The display will go off 1 minute after you press the sleep button.
- Swing: Press the button, when the louver swings to your desired position, press the button again to fix it.
- Child lock: Press the”+” and “-” buttons together for 3s to activate the child lock function.
- WIFI indicator: Press the Power button for 5s to enter network configuration mode, and the indicator flashes. When the network configuration is complete, the indicator remains on.
- Full indicator: When the indicator is on, the unit needs drainage.
Operating Instructions of the Remote Control
The operation interface of the remote control is as follows
Instructions of key operation of the high-quality remote control are as follows:
- Power: Press the key to turn on or turn off the machine.
- Mode: press the key to switch between cooling, air supply, and dehumidification mode.
- Up: press the key to increase temperature and timing set value.
- Down: press the key to reduce temperature and timing set value.
- Fan: press the key to select high, medium, and low wind speed output circularly.
- Timer: press the key to set the timing value.
- Swing: Press the key to fix the louver in your desired position.
- Press on the key to switch between Celsius and Fahrenheit.
- Sleep Mode: Press the key to turn on the sleep mode.
NOTE: AAA 1. SVDC battery { not included )
Variety of Protection Functions
Frost Protection Function:
In cooling, dehumidification, or economic power saving mode, if the
temperature of the exhaust pipe is too low, the machine will automatically
enter protection status; if the temperature of the exhaust pipe rises to a
certain temperature, it can automatically revert to normal operation.
Overflow Protection Function:
When the water in the water pan exceeds the warning level, the machine will
automatically sound an alarm, and the Full indicator w111 turn on. At this
point, you need to move the drainage pipe connecting the machine or the water
outlet to the sewer or other drainage area to empty the water (details see
Drainage Instructions). After the water is emptied, the machine will
automatically return to its original state.
Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay
booting protection function after the compressor is turned off.
Drainage Instructions
Manual drainage:
-
When the machine stops after the water is full, turn off the machine power and unplug the power plug.
Notes: Please move the machine carefully, so as not to spill the water in the water pan at the bottom of the body. -
Place the water container below the side water outlet behind the body.
-
Un screw the rotary knob. and unplug the rubber stopper, the water will automatically flow to the water container.
Notes:
- Keep the rotary knob and rubber stopper properly.
- uring drainage, the body can be tilted slightly backward.
- If the water container cannot hold all the water before the water container is full, stuff the water outlet with a rubber stopper as soon as possible to prevent water from flowing to the floor or the carpet.
- When the water is discharged, stuff a rubber stopper, and tighten the rotary knob.
Notes:
- Restart the machine after the rubber stopper and rotary knob are installed, otherwise, condensate water of the machine will flow to the floor or the carpet.
- Continu_ou~ drainage (only applicable to cooling and dehumidification mode), as shown m figure:
- Unscrew the rotary knob, and unplug the rubber stopper.
- Set the drainage pipe into the water outlet.
- Connect the drainage pipe to the bucket.
MAINTENANCE
Cleaning: Before cleaning and maintenance, turn off the machine and unplug the plug.
Clean the surface
Clean with surface of the machine with a wet soft cloth. Don’t use chemicals,
such as benzene, alcohol, gasoline, etc.; otherwise( the surface of the air
conditioning will be damaged or even the whole machine wi be damaged.
Clean the filter screen
- If the filter screen is clogged with dust, and the effectiveness of the air conditioning is reduced, be sure to clean the filter screen once every two weeks.
- Clean the upper filter screen frame Clasp the wedging block of the filter screen frame with your hands. Force down from the outside to remove the filter screen frame. Unscrew four screws fixing the filter screen and the rear housing to remove the EVA filter screen (as shown in the above figure).
Put the filter screen into warm water with neutral detergent (about 40°C / 104 °F) and dry it in the shade after rinsing clean.
Postseason Storage
- Unscrew the rotary knob, unplug the rubber stopper( and discharge the water in the water pan into other water containers or directly tilt the body to discharge the water into other containers.
- Turn on the machine, adjust it to low-wind ventilation mode1, and maintain this state until the drainage_fipe bec;ome~ dry, to keep the inside of the body in a dry state and prevent I from m1ldewmg.
- Turn off the machine, unplug the power plug, and wrap the power cord around the wrapping post; install a rubber stopper and the rotary knob.
- Remove the exhaust pipe and keep it properly.
- Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place, keep it out of the reach of children, and tal<e dust control measures.
- Remove the batteries of the remote control and keep them properly.
Note: ensure that the body is placed in a dry place and keep all machine components properly.
TROUBLESHOOTING
Do not repair or disassemble the air conditioning by yourself. Unqualified repair will lead to failure of the warranty card, and may cause damage to users or their properties
Problems | Reasons | Solutions |
---|
The air conditioning does not work.
| There is no electricity.| Turn it on after connecting it to
a socket with electricity.
The overflow indicator displays “FL”| Discharge the water inside
The ambient temperature is too low or too high| Recommend using the machine at
the temperature
of 7-35°C (44-95 °F)
In cooling mode, the room temperature is lower than the set temperature; in heating mode, the room temperature is higher
then the set temperature.
|
Change the set temperature.
In dehumidification mode, the ambient temperature is low.| The machine is placed in a room with an ambient temp:erature of greater than 17
0c ( 2 °F).
The cooling or heating effect is not good
| There is direct sunlight.|
Close the curtain.
Doors or windows are open then are a l!)t of people! e; or in cooling moe, there are other
sources of heat.
|
Close doors and windows, and add new air conditioning.
The filter screen is dirty| Clean or replace the filter screen
The air inlet or outlet is blocked.| Clear obstructions.
Big Noise| The air conditioning is not placed on a flat surface.| Put the air
conditioning in a flat and hard place (to reduce noise).
The compressor
does not work
| Overheat protection starts.| Wait for 3 minutes until the temperature is lowered, and then
restart the machine
The remote control does not work.
| The distance between the machine and the remote control is too far.|
Let the remote control get close to the air conditioning, and make sure that the remote control directly faces the direction of the remote control receiver.
The remote control is not aligned with the direction of
the remote control receiver.
Batteries are dead| Replace batteries
Displays ‘E1’.| The room temperature sensor is abnormal| Check the room
temperature sensor and related circuitry
Displays ‘E2’| The pip_e temperature
sensor Is abnormal.
| Check the line temp. erasure
sensor and related circuitry.
If problems not listed in the table occur or recommended solutions do not work, please contact the professional service organization
WARRANTY: 1 YEAR
QR SCAN
AIGOSTAR INC 489 YORBITA RD, CITY OF INDUSTRY, CA 91744(UNIT A)
http://www.aigostar.com
MADE IN CHINA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>