Pulsar AWOP-425SR Distribution Junction Box Instructions

June 1, 2024
Pulsar

Pulsar AWOP-425SR Distribution Junction Box

Pulsar-AWOP-425SR-Distribution-Junction-Box-product

Specifications

  • Product Name: Distribution Junction Box 4×2,5mm2
  • Model: AWOP-425SR v.1.0
  • Edition: 5 from 05.02.2024
  • Supersedes Edition: 4 from 21.05.2019
  • National Technical Assessment: CNBOP-PIB-KOT-2019/0109-3704
  • 3rd Edition of 23 May 2019

Description:

The junction box for fire alarm systems is designed for connecting fire protection devices in cable installation systems with fire resistance according to the DIN 4102-12 standard. It ensures uninterruptible power supply or signal transmission in case of fire. The box is designed to maintain cable routes for power supply and signal transmission in fire zones. It can be used for various fire protection equipment.

Elements of the junction box:

Component No. Description
1 Mounting holes for mounting to a surface.
2 Cable glands.
3 Protection connector PE.
4 Connection sockets.
5 Mounting for indicator.
6 Cable gland for indicator.

Installation:

The junction box should be mounted directly to concrete base class min. B20 or natural stone. It can be mounted on the ceiling or wall using steel pins with proper fire resistance. Cables should be mounted with handles at intervals of 600 mm. Ensure proper mounting distances and follow boundary conditions provided in the manual.

WEEE LABEL: Waste electrical and electronic equipment must be disposed of separately according to the European Union WEEE Directive.

Contact Information:

Pulsar sp. j. Siedlec 150, 32-744 Lapczyca, Poland
Tel: (+48) 14-610-19-45
Email: sales@pulsar.pl
Website: www.pulsar.pl

FAQ

  • Q: Can I use this junction box for any type of fire protection equipment?
    • A: The junction box can be used for various fire protection equipment such as ventilators, smoke vents, fire alarm control panels, and emergency warning systems.
  • Q: What is the maximum mounting distance between cables and the edge of the junction box?
    • A: The maximum mounting distance is 100 mm.
  • Q: How should I dispose of waste electrical and electronic equipment?
    • A: Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, it should be disposed of separately from normal household waste.

National Technical Assessment CNBOP-PIB-KOT-2019/0109-3704 3rd edition of 23 May 2019. National assessment and verification of constancy of performance CNBOP-PIB 063-UWB-0174

Description

The junction box for fire alarm systems is designed for connecting fire protection devices in cable installation systems with fire resistance according to the DIN 4102-12 standard, where the uninterruptible power supply or transmission of the signal in case of fire is required. The junction box is designed to guarantee the mechanical ability to keep the cable routes capable of guaranteeing the uninterruptible power supply and transmission of telecommunication signals in the fire zone. The junction box can be used for power supply of fire protection equipment, such as ventilators and smoke vents, fire alarm control panels, emergency warning systems, etc. Juction box enable to connect and split 2 wires cable. The enclosure s equipped with mounting sleeves to mount the optical – acoustic indicator

Table 1. Elements of the junction box.

Component

No.

| Description
---|---
[1]| Mounting holes for mounting to a surface.
[2]| Cable glands.
[3]| Protection connector PE.
[4]| Connection sockets.
[5]| Mounting for indicator
[6]| Cable gland for indicator

Pulsar-AWOP-425SR-Distribution-Junction-Box-fig \(2\)

 Technical parameters

Table 2. Technical parameters

Voltage 450V AC max
Diameter of installation cable Max. 10mm
Cross-section of the cable Max. 2,5mm2
Protection class IP20
Enclosure DC01 1mm steel plate, color RAL 3001 (red)
Dimensions 120 x 120 x 37 [mm] (WxHxD)
Temperature range during installation -25ºC to +60ºC
Mounting 100mm Φ5,5 mm
Net/gross weight 0,48 / 0,52 [kg]

Installation

The junction box for fire alarm systems should be mounted directly to the concrete base class min. B20 or natural stone. Other building materials of adequate strength and of fire resistance class of at least R90 are also approved for use.
The junction box for fire alarm systems should be mounted to the ceiling or wall using two steel pins of adequate fire resistance. The cables should be mounted using handles at intervals of 600 mm. Mounting distance between the cables (handles) and the edge of the junction box is maximally 100 mm.

Pay attention to the following boundary conditions:

  • a) The bushings and expansion bolts should be recessed at least 30 mm into the concrete.
  • b) Tension on the pin should not exceed 500 N.
  • c) Alternatively, the pins with well-documented fire protection design can also be used.
  • d) It should be ensured that the functional class of the cable assemblies containing junction boxes for fire alarm systems will not be adversely affected by falling building elements.

Installation cables should be led through the appropriate bushings and then mounted with cable holders located inside the enclosure.

WEEE LABEL

Waste electrical and electronic equipment must not be disposed of with normal household waste. According to European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste

Contact

Pulsar sp. j.

QR CodePulsar-AWOP-425SR-Distribution-Junction-Box-fig
\(3\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Pulsar User Manuals

Related Manuals