1VAHG7500 Ceiling Mount Electric Heater

TECHNICAL DATA
HARDWIRED INSTALLATION REQUIRED
This heater must be grounded and hardwired to a properly sized current protection circuit breaker in accordance with the (US) National Electric Code and local codes.
FEATURES:

  • Adjustable Heat Settings with Digital Thermostat
  • Fan-Forced for Wide Heat Circulation
  • Fan Only Setting for Year-Round Air Circulation
  • 12-Hour Timer with Auto Shut-Off
  • Horizontal and Vertical Air Flow with Tilt Feature
  • Sturdy Heavy-Gauge Steel Body
  • Remote Control
  • High Limit Thermal Cut-Out Switch

1VAHG7500 DIGITAL HEAVY DUTY 7,500W ELECTRIC UTILITY HEATER

WATTS SWITCH POSITION VOLTS (VAC) PHASE AMPS BTU/HOUR
7,500W High (default) 208-240V, 60Hz 1 31.3 25,590
6,250W Low 208-240V, 60Hz 1 26 21,330
N/A Fan Only N/A N/A N/A N/A
Air Throw Horizontal 18 Ft. (Approx.)
Recommended Circuit Breaker 40 Amp or larger, in accordance with NEC and

local codes.
Recommended| Wire Size| 8 AWG, Copper Only, Rated at 167°F / 75°C| or larger, hardwired in accordance with NEC and local codes.
Recommended Lug Torques| 40 In.-Lbs.| or greater, in accordance with NEC and local codes
Product Weight (Approx.)| 20.75 Lbs.|

WARNING: The installation of main power supply is highly recommended to be carried out by a certified electrician. The installation process involves working with electrical components, which can be dangerous and potentially life-threatening if handled incorrectly.
IMPORTANT NOTE:
Read the manual carefully. Make sure to save this manual for future reference.
Illustrations in this manual are for explanatory purposes only, your actual product may look slightly different.
CONSUMER PRODUCT INFORMATION
For your own records, please attach a copy of your sales receipt to this manual.
Also, write the store name/location and date purchased below:
Store Name: ____
Location: __
Date Purchased: _____

SAFETY GUIDELINES

INTENDED USE:
Electric Utility heaters are designed to meet a variety of heating requirements. This product is intended for indoor use only. Use only with electrical wiring that is in good working order and that meets applicable codes and ordinances.
If you have any questions whether your wiring is adequate, consult a qualified electrician. Risk of fire, overheating, malfunction, property damage, injury or even death may result if not adhered to.
Use your heater/fan only with a working smoke detector located in the vicinity of your heater/fan.
While using your heater/fan, you should follow the IMPORTANT INSTRUCTIONS listed below. As part of those instructions, we have used the word “WARNING” to indicate the level of hazard: WARNING indicates a hazard which, if not avoided, could result in injury or death.
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
WARNING – Read and understand installation and operation instructions and observe all safety instructions

  1. For supply connections, use only copper wire, see SPECIFICATIONS.
  2. Heater air flow must be directed parallel to, or away from adjacent wall.
  3. Observe wall, floor, and ceiling clearance requirements. See Figure. 1.
  4. All wiring must conform to national and local electrical codes in the United States and the heater must be grounded as a precaution against possible electrical shock. Heater circuit must be protected with proper fuses or circuit breakers.
  5. The mounting structure and the anchoring hardware must be capable of reliably supporting the weight of the heater and, if used, the mounting bracket.
  6. All electrical power must be disconnected, and the main service box must be locked before inspection, cleaning or servicing the heater. This is a precaution to prevent serious shock.
  7. This heater is not suitable for use in hazardous locations as defined by the National Fire Protection Association (NFPA) in the United States. This heater has hot and arcing (sparking) parts inside. Do not use in areas where gasoline, paint, or flammable liquids are used or stored.
  8. This heater is not suitable for use in corrosive atmosphere such as marine, greenhouses or chemical storage areas.
  9. Do not install closer than 8 inches to a vertical surface. Do not install less than 6 feet from the floor.
  10. Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
  11. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.

WARNING – Improper installation or failure to follow the procedures outlined in this instruction manual can result in serious electrical shock.
WARNING: SHOCK HAZARD
Use your heater only in dry environments. This heater is not intended for use in a bathroom, laundry area, or similar locations, or near sinks, washing machines, swimming pools or other sources of water. Never locate heater where it may fall into a bathtub or other water container. Do not use heater outdoors. Do not use in damp environments such as flooded basements.
WARNING: HOT SURFACES
Do not touch body of heater when in use. This heater is hot when in use, to avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this heater.
WARNING: FIRE HAZARD
Heater has hot and arcing or sparking parts inside. Do not use near combustible materials or flammable gases or sources of heat. DO NOT USE in areas where gasoline, paint or flammable materials are used or stored. Keep combustible materials such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet (0.9 meters) from the front of the heater and keep them away from the sides and rear. Keep rear grille away from walls or drapes so as to not block air intake.
To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire, or damage the heater.
WARNING: ELECTRICAL SHOCK HAZARD
Do not use with damaged cord or plug. Use with adequate electrical system that is up to code. Do not operate any heater with a damaged cord or plug or after heater malfunctions, has been dropped or damaged in any manner. Do not operate heater with a broken heating element or ceramic cone or any visual imperfections.
PET OWNERS NOTE
The health of birds and some small pets are extremely sensitive to the fumes given off during the initial use of many appliances. Although these fumes are not harmful to humans, it is recommended that this heater not be used around birds and small pets during its initial use until the manufacturing corrosion coatings burn off.
INSTALLATION WARNING
WARNING: FOR INDOOR USE ONLY, IN A DRY LOCATION FREE OF GASOLINE, PAINT, FLAMMABLE LIQUIDS OR COMBUSTIBLE DUST OR MATERIALS. DO NOT USE EXTENSION CORDS.
FIGURE 1
NOTE: Diagram is not drawn to scale; for information purposes only.
Product dimensions are approximate and subject to change without notice. MAXIMUM MOUNTING HEIGHT USING BRACKET FOR HORIZONTAL/ANGLED AIR FLOW:
The maximum recommended ceiling height for effective vertical air flow is 8 ft.

OPERATING INSTRUCTIONS

OPERATION AND TEMPERATURE SETTING

  1. This heater is designed to maintain a comfortable room temperature. Always operate the heater in the upright position following all instructions and recommendations listed in this manual.
    When the heater is turned on by pressing the POWER button, it will operate on HIGH setting (7,500W) continuously. The LED display panel will show the ambient temperature. Press the MODE button on either the unit or remote to change the heat setting to LOW (6,250W). The fan will start running about 10 seconds after initial start to push the heat out. The sequence is HIGH-LOWFAN- ONLY. To  operate the unit on FAN ONLY setting, press the MODE button again. In FAN ONLY mode, the LED display panel will show FA to indicate the heater is in FAN ONLY mode. From FAN ONLY mode, pressing the MODE button will make the heater operate in HIGH setting again, and the ambient temperature will appear on the LED display.

  2. The temperature setting can be adjusted between 45°F (7°C) to 95°F (35°C). To change the temperature, press the TEMP+ or TEMP – buttons on either the unit or the remote. (See Figure 2).

  3. The temperature display will blink while it is being adjusted. When the desired temperature is reached, it will take about 5 seconds to accept the setting. Once the display stops flashing, the room temperature will reappear on the LED screen to indicate the desired temperature is set.

  4. In any temperature mode, the unit will stay in that mode, cycling on and off to maintain the set temperature. The heater will reach the set temperature faster in HIGH setting.

  5. The heater can be turned OFF by pressing the POWER button. Once the unit is turned off, the fan will continue to run to cool down the unit and there will be a 90 seconds countdown on the digital display.

TIMER FUNCTION:

The Timer function allows you to set the length of operation from 1 to 12 hours.
Each time the TIMER button is pressed the length of operation will increase 1 hour. The duration the timer is set for will be displayed on the LED screen in hour increments.
TO TURN THE TIMER FUNCTION OFF: Press the TIMER Button continuously until the LED screen displays “O”.
NOTE: The timer function is not an excuse to leave the heater unattended.
NOTE: Heater will cycle on and off to maintain room temperature. The first time you operate the unit, it may smoke slightly. This is due to residual cleaning agents used to clean the element when the heater is manufactured. This is normal and does not indicate a problem with the unit. This condition will stop after the heater has been in operation for a few minutes.
FAHRENHEIT OR CELSIUS DISPLAY:
To switch the display between Fahrenheit and Celsius, press the °F/°C on either the unit or the remote.

INSTALLING THE HEATER

LOCATING THE HEATER
Install the heater out of traffic areas, maintaining the clearances stated in Figure 1.
The air flow from the heater must not be restricted or obstructed by any items in the room. When more than one heater is used in an area, the heaters should be arranged so that the air discharge of each heater supports the air flow of the others to provide best circulation of warm air, as indicated below in Figure 3. MOUNTING BRACKET INSTALLATION
Refer to Figures 4a and 4b.

  1. Locate a ceiling joist or other firm structural element or support to mount the heater and point at desired direction of air flow.

  2. Drill a ¼” pilot hole in the ceiling joist for the screws.

  3. Place the screws and washers as shown in the Figures 4a or 4b.
    Fig. 4a: For Single-Screw Mounting (center bracket hole only). (If you want to swivel the heater, a longer Lag bolt may be required to properly secure the heater, not included.)
    Fig. 4b: For Double-Screw Mounting (both off-center holes are used).

  4. Tighten the screws to secure the heater.

HANGING THE HEATER IN THE BRACKET

  1. Lift the heater into the mounting bracket and align the lower bracket holes with the threaded holes nearest the heater’s center.
  2. Thread a large knob-screw through the hole on each side of the bracket.
  3. Aim the heater horizontally or tilted by aligning the upper bracket holes with the top threaded holes on the heater and secure with the small knob-screws and tighten all. See Figure 5.

CONNECTING THE POWER

WARNING: The installation of main power supply is highly recommended to be carried out by a certified electrician. The installation process involves working with electrical components, which can be dangerous and potentially life-threatening if handled incorrectly.

  1. With the power off at the breaker, remove all screws from the bottom lid for access to the electrical section of the heater.

  2. Attach flexible cable through a knockout in the side of the heater following NEC and local codes, See Figure 6 and SPECIFICATIONS for recommended wiring and circuit breakers. Ceiling Joist Washer Bracket Bracket
    NOTE: For certain applications, conduit may be required. See Figure 6. Check local electrical codes. If you run the wiring in conduit and wish to be able to turn the heater be sure to purchase enough flexible conduit to allow the heater to be turned. 3/8″ Diameter Bracket Lag Bolt Bracket

  3. Pull enough wire into the heater and connect to wire to the Power Block located in the electrical area of the heater. See Figure 7.

  4. Be sure to torque all terminal screws and power block lugs tight, see SPECIFICATIONS and NEC/local codes, for required torque values, failure to do so can overheat the power blocks.

  5. Turn on power at the main circuit breaker panel. Notice the YELLOW Power Indicator Light on the Control Panel will glow.

WARNING: It is advised that at the start of each heater season, the power should be turned off at the circuit breaker, and the LI and L2 lug screws checked for tightness and proper torque. The heater should be cleaned and checked for mechanical and electrical integrity. See SPECIFICATIONS and NEC/local codes.

CARE AND MAINTENANCE

ADJUSTING AIR FLOW:

  1. Swivel the unit—If mounted on a single center lag bolt Figure 4a, turn the entire heater and bracket assembly left or right.
  2. Tilt the unit—Loosen the top Small Knob-Screws and thread into provided holes in heater until tight. See Figure 5.
  3. Adjust the louvers in front of the heater as desired. See Figure 5.
    NOTE: DO NO OPERATE THE HEATER WITH THE FRONT LOUVERS CLOSED, DAMAGE TO THE HEATER COULD RESULT.

SAFETY INSTRUCTIONS:
To start the heater, turn on the circuit breaker. The Power Indicator light will light up to indicate there is power available. Press the POWER button to turn the heater on. The heater will be in HIGH setting by default. The heater indicator will illuminate, and the LED display will show the default setting temperature 80°F.

  1. The heater is HOT when in use. Do not let bare skin touch any hot surfaces.
  2. Keep combustible materials (furniture, pillows, bedding, papers, clothes, curtains, and similar items) at least 3 feet (0.9m) from all sides and surfaces of the heater.
  3. Do not use outdoors or in wet areas like bathrooms, laundry areas or where it could fall into a swimming pool or other container of water.
  4. This heater is a 240V AC rated direct wired appliance. Never use extension cords or relocatable power taps.

CLEANING THE HEATER

  1. Do not disassemble the heater to clean it.
  2. The heater should be powered OFF and disconnected from the power at the circuit breaker before attempting to clean any portion of the heater.
  3. The exterior can be cleaned with a cloth, brush and/or vacuum.
  4. The louvers, fan blade and heating element are delicate and should not encounter hard items. They can be cleaned by brush, vacuum and mild compressed air.

MAINTENANCE:
This Industrial Heater contains no user serviceable parts.

4560 W. 160th Street
Cleveland, OH 44135
833-950-1185 | support@visionairproducts.com
www.visionairproducts.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals