CERAMIC UTILITY HEATER
10” | 1500 / 750W
1VAHCU10 Utility Ceramic Electric Heater
MODEL 1VAHCU10
TECHNICAL DATA
Model: 1VAHCU10
Voltage: 120V~ / 60Hz
Watts: 750W Low / 1500W High
BTUs: 5120
Features:
- Adjustable Thermostat
- Three Settings: High / Low / Fan Only
- Top Mounted Control Panel
- Power and Caution Indicator Lights
- Safety Overheat Protection
- Convenient Stay Cool Carry handle
- QuietHighEfficiencyFan
- Sturdy Metal Body
CONSUMER PRODUCT INFORMATION
For your own records, please attach a copy of your sales receipt to this
manual.
Also, write the store name/location and date purchased below:
Store Name: _
Location: ___
Date Purchased: __
IMPORTANT NOTE:
Read the manual carefully. Make sure to save this manual for future reference.
Illustrations in this manual are for explanatory purposes only, your actual
product may look slightly different.
SAFETY GUIDELINES
INTENDED USE:
This product is intended for indoor residential and office use only, not for
industrial or other commercial application. Use only with electrical wiring
that is in good working order and that meets applicable codes and ordinances.
This heater must be plugged in to a 120V AC, 15 Amp. (or larger) circuit. Do
not plug anything additional into the same circuit. If you have any questions
whether your wiring is adequate, consult a qualified electrician. Risk of
fire, overheating, malfunction, property damage, injury or even death may
result if not adhered to. Use your heater/fan only with a working smoke
detector located in the vicinity of your heater/fan.
While using your heater/fan, you should follow the IMPORTANT INSTRUCTIONS
listed below. As part of those instructions, we have used the word “WARNING”
to indicate the level of hazard: WARNING indicates a hazard which, if not
avoided, could result in injury or death.
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed
to reduce the risk of fire, electric shock and injury to persons, including
the following:
- Read all the instructions before using this heater/fan.
- This heater/fan is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Use provided handle when moving this heater. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet (0.9 meters) from the front of the heater/fan and keep them away from the sides and rear.
- Do not use heater unattended. Use of extreme caution is necessary when any heater is used by or near children, invalids, disabled persons or pets.
- Do not operate the heater with a damaged power cord or after the heater malfunctions, has been dropped or damaged in any manner. Return heater to authorized service facility for examination, electrical or mechanical adjustment or repair.
- Do not use heater outdoors.
- Use your heater only in dry environments. This heater is not intended for use in a bathroom, laundry area, or similar locations, or near sinks, washing machines, swimming pools or other sources of water. Never locate heater where it may fall into a bathtub or other water container. Do not use in damp environments such as flooded basements.
- Do not place the heater on a small, unlevel, uneven or any surface which might allow heater to tip or fall.
- For proper operation, heater should be placed on a smooth, non-combustible surface. Do not place on rugs, carpet, vinyl flooring or other plastic surfaces. Not for use outdoors or in wet areas
- This heater is not designed as a primary heat source.
- Always plug heaters directly into a wall outlet/receptacle. Never use with an extension cord or relocatable power tap (outlet/power strip). Always unplug heater when not in use.
- Do not run power cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Arrange cord away from traffic area where it will not be tripped over.
- To disconnect heater, turn controls off then remove plug from outlet.
- Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater.
- To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces like a bed, where openings may become blocked.
- A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are used or stored.
- Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons or property.
WARNING: SHOCK HAZARD
Use your heater only in dry environments. This heater is not intended for use
in a bathroom, laundry area, or similar locations, or near sinks, washing
machines, swimming pools or other sources of water. Never locate heater where
it may fall into a bathtub or other water container. Do not use heater
outdoors. Do not use in damp environments such as flooded basements.
WARNING: HOT SURFACES
Do not touch body of heater when in use. This heater is hot when in use, to
avoid burns, do not let bare skin touch hot surfaces. If provided, use handles
when moving this heater.
WARNING: FIRE HAZARD
Heater has hot and arcing or sparking parts inside. Do not use near
combustible materials or flammable gases or sources of heat. DO NOT USE in
areas where gasoline, paint or flammable materials are used or stored. Keep
combustible materials such as furniture, pillows, bedding, papers, clothes and
curtains at least 3 feet (0.9 meters) from the front of the heater and keep
them away from the sides and rear. To prevent a possible fire, do not block
air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed,
where openings may become blocked. Do not insert or allow foreign objects to
enter any ventilation or exhaust opening as this may cause an electric shock,
fire, or damage the heater.
WARNING: ELECTRICAL SHOCK HAZARD
Do not use with damaged cord or plug. Use with adequate electrical system that
is up to code. The supply cord has a polarized plug. As a safety feature this
plug will fit in a polarized outlet only one way. To prevent electric shock,
match wide blade of plug to wide slot, fully insert plug. If the plug does not
fit contact a qualified electrician. Do not operate any heater with a damaged
cord or plug or after heater malfunctions, has been dropped or damaged in any
manner. Do not operate heater with a broken heating element or ceramic cone or
any visual imperfections.
PET OWNERS NOTE
The health of birds and some small pets are extremely sensitive to the fumes
given off during the initial use of many appliances. Although these fumes are
not harmful to humans, it is recommended that this heater not be used around
birds and small pets during its initial use until the manufacturing corrosion
coatings burn off.
USAGE
ASSEMBLY INSTRUCTIONS
Simple assembly is required before you use this heater.
- Remove Screw “A” on both sides of heater using a phillips screwdriver.
- Rotate base cradle to align Hole “B” with new open hole from screw “A”.
- Replace screw “A” through screw hole “B” on both sides of heater.
- Heater is now ready for use.
HEATER OPERATION
Always operate the heater in the upright position following all instructions
and recommendations listed in this manual. HEATER LOCATION: Place the heater
in the area of the room that is coldest. HEATER CONNECTION: Plug heater
directly into 120 Volt AC, 60Hz wall outlet. Be sure plug fits tightly in
outlet. A loose connection may cause overheating and damage to the plug or
heater.
NOTE: To prevent overloading a circuit, do not plug the heater into a
circuit that is servicing other electrical needs.
POWER/CAUTION LIGHTS
This heater is equipped with Power and Caution Lights. The power light will
illuminate when the unit is plugged in. The Caution Light will illuminate when
the unit overheats. When the Caution Light is illuminated, turn off and unplug
the heater. Follow the “Important Safety Features” located in this manual.
TURNING HEATER ON
To start the heater, turn the On/Off Power Level Control from the OFF posi
tion to the LOW or HIGH setting. Then rotate the Thermostat Control
clockwiseto the HIGH THERMOSTAT position as described below. (During the
heaters initial use, you may experience a slight odor or smoking. This is the
result of the heating element lubrication “burning off”. This is normal and
will go away after a few minutes of use.)
POWER INDICATOR
The Power Indicator Light will illuminate when the heater or fan is turned on.
POWER CONTROL DIAL
This heater has two heat settings: High and Low. Use the higher setting (1500
watt) to raise the room temperature quickly. When the desired temperature is
reached use the Low setting. It is usually sufficient to maintain a
comfortable temperature.
SETTING THERMOSTAT
After heater has been turned on and the room has reached the desired
temperature, slowly rotate the thermostat knob counter-clockwise until the
heater shuts off (you should hear a faint “click”). By leaving the thermostat
at this setting it will automatically maintain this temperature. To lower
temperature, rotate the knob further counter-clockwise (towards the LOW
position). To raise the temperature, rotate the thermostat knob clockwise
(towards the HIGH position).
TO OPERATE FAN ONLY
Turn the On/Off Power Level Control dial to the Fan setting. Turn thermostat
fully clockwise so the fan will run continuously
TURNING OFF
Turn the center dial to the OFF position before unplugging or plugging in the
heater. Heater should be unplugged when not in use.
IMPORTANT SAFETY FEATURES
The power indicator light, located near the control panel, lights whenever the
heater or fan is turned on. The heater is equipped with an automatic overheat
protection device located inside the body of the heater. If the heater grille
is obstructed, or if the heater gets too hot for any reason, the automatic
overheat protection device will turn the heater off. To reset the heater,
simply turn power off and unplug the heater for 10 minutes until it cools
down, and then you may plug the heater in and restart. Be sure that the heater
is on a smooth level surface with no obstructions.
CARE AND MAINTENANCE
CLEANING
CAUTION-Before cleaning the heater be sure to disconnect power cord and
allow the heater to cool completely. This heater should be cleaned at least
once a year to maintain proper performance. Clean the outside surface with a
clean, damp cloth. Do not use harsh chemical or abrasive cleaners. DO NOT
IMMERSE THE HEATER IN WATER. Allow heater to dry completely before use.
REPAIR
DO NOT OPERATE THE HEATER WITHOUT THE GRILLE IN PLACE. DO NOT USE THE HEATER
IF IT HAS MALFUNCTIONED OR BECOME DAMAGED IN ANYWAY.
STORAGE
Keep original carton for storage of the heater. Coil and tie the power cord to
avoid damage during storage.
4560 W. 160th Street
Cleveland, OH 44135
833-950-1185
support@visionairproducts.com
www.visionairproducts.com
Printed in China
0323_M029
Documents / Resources
|
VISIONAIR 1VAHCU10 Utility Ceramic Electric
Heater
[pdf] Owner's Manual
1VAHCU10, 1VAHCU10 Utility Ceramic Electric Heater, Utility Ceramic Electric
Heater, Ceramic Electric Heater, Electric Heater, Heater
---|---