Installation Requirements

The Rotary Iron may only be commissioned by Miele Customer Service or by a Miele specialist dealer.

  • The Rotary Iron must be installed in accordance with applicable regulations and standards. Local energy supplier regulations must also be observed.

Operating conditions

  • Ambient temperature: +40°F to +105°F (+5°C to +40°C)
  • Humidity: 10% to 85%
  • At a +70°F (+21°C) ambient temperature, the maximum permissible relative humidity is 70%.

The Rotary Iron must not be operated in the same room as dry cleaning equipment using perchloroethylene or solvents containing CFCs.

Installation

The Rotary Iron should be transported to the installation site using a suitable pallet truck. Do not remove the packaging until right before the appliance is used for the first time.
The lateral mounting flaps must be fitted before transporting the Rotary Iron or lifting it off the wooden frame.
The suspension points for lifting hooks/straps are located under the side columns between the screw-on feet.
During installation, ensure that the clearance next to and behind the appliance columns is at least 2 5/8″ (600 mm) so that the cover panels remain accessible.
The clearance in front of the Rotary Iron must amount to at least 5 ft (1.5 m) to prevent foreign materials (cabinetry, walls) from getting hot.
There should be a clearance of at least 3.3 ft (1 m) above the appliance.
During transportation of the Rotary Iron, ensure its stability. The Rotary Iron must not be transported without the wooden frame. If the Rotary Iron needs to be transported again (e.g., if you are moving location), it must be lifted onto the wooden frame and secured on it.

Leveling the appliance

To ensure the Rotary Iron functions correctly and energy-efficiently, it must be leveled horizontally by means of the screw-on feet.

  • Dismantle the mounting flaps on the left and right sides.
  • Align the appliance using the screw-on feet and a level in such a way that the roller and the side columns are level with each other. For this purpose, the screw-on feet can be unscrewed up to a maximum of 2 1/2″ (60 mm).
  • After leveling the appliance, secure the screw-on feet with the nuts so they cannot come loose.

Floor Anchoring

Suitable anchoring materials for the Rotary Iron are available as optional accessories from Miele Customer Service. Alternatively, the tensioning strips that secured the Rotary Iron to the transport pallet for delivery may be used to anchor the appliance to the floor.
Tensioning strip from the transport pallet
Floor Anchoring

  • Coin-operated rotary irons must be anchored to the floor by the supporting feet to prevent the risk of the machine tipping.

Electrical Connection

The electrical connection must be carried out by a qualified electrician who must ensure that all electrical work is completed in accordance with applicable regulations and standards.
A power cord is not included with the machine. Please ensure that a power cord is available for installation.
The electrical connection and the wiring diagram are located behind the mounting flap of the right side column.
If the appliance is hard wired, an appropriate sized circuit breaker must be installed on site. Switches with a minimum contact gap greater than 1/8″ (3 mm) are suitable disconnectors.
The plug connector or disconnector must be easily accessible at all times.
If the Rotary Iron is disconnected from the electricity supply, the disconnector must be lockable or the point of disconnection must be within clear view of the appliance.
If it is necessary to install a residual-current device (RCD) in accordance with the local regulations, a type-A residual-current device can be used.

Vent Ducting

Risk of fire if vent ducting is not fitted correctly.
The vent ducting must not be channeled into a chimney or flue which is already in use for any type of burning installation (gas, coal, or oil). The vent ducting for the Rotary Iron must be installed separately from the vent ducting for any tumble dryers.

The warm and moist exhaust air from the Rotary Iron must be conducted outdoors or to a suitable venting duct via the shortest possible path.
Suitable measures must be taken to prevent condensate from flowing back into the Rotary Iron. If the fan is not powerful enough to remove the moist air, a suitably powerful additional fan must be fitted in the shaft or the roof outlet on site. There must be sufficient air intake to the installation site to match the air outlet volume.

  • The connector for the vent ducting is located on the rear of the left side column and has a diameter of 2 3/4″ (70 mm) (HT DN 70).
  • The exhaust ducting must have an internal diameter of 2 3/4″ (70 mm) (HT DN 70).
  • If the vent ducting is directed upwards, a condensate drain hole with a diameter of approx. 1/8″-1/3″ (3–5 mm) must be provided at the lowest point.
  • Adequate ventilation of the installation room must be ensured.
  • The on-site vent ducting and the exit point to the outdoors must be checked on a regular basis for a build-up of lint. Clean them whenever necessary.
  • The end of the ducting leading outdoors must be protected against the elements (e.g., with a downward-facing 90° elbow).

Ducting Lengths

Type of elbow Length of ducting

*PRI 210
PRI 214
PRI 217
Ducting Lengths**| 90° elbow| r = 2d| 0.8 ft (0.25 m)
45° elbow| r = 2d| 0.5 ft (0.15 m)
| 90° elbow| r = d| 1.15 ft (0.35 m)
45° elbow| r = d| 0.8 ft (0.25 m)
Ducting Lengths| 90° concertina bend| r = 2d| 2.3 ft (0.7 m)
45° concertina bend| r = 2d| 1.8 ft (0.55 m)
Ducting Lengths| 90° segmented bend
(3 welded seams)| r = 2d| 1.5 ft (0.45 m)
45° segmented bend
(3 welded seams)| r = 2d| –
Ducting Lengths| 90° elbow, Westa flex ducting| r = d| –
r = 2d| 1.6 ft (0.5 m)
r = 4d| 1.15 ft (0.35 m)
45° elbow, Westa flex ducting| r = d| –
r = 2d| 1.3 ft (0.4 m)
r = 4d| 1 ft (0.3 m)

Based on the number of bends, the ducting lengths must be deducted from the maximum permissible total ducting length.

Maximum permissible total ducting length

Clear minimum ducting diameter
(metal ducting)| Maximum permissible total ducting length
(exhaust air)
---|---
*PRI 210
PRI 214
PRI 217**
2 3/4″ (70 mm)| 16.4 ft (5 m)
3 1/8″ (80 mm)| 65.6 ft (20 m)
3 1/2″ (90 mm)| 105 ft (32 m)
4″ (100 mm)| 131.2 ft (40 m)

*with optional extraction fan

Once the Rotary Iron has been successfully installed and connected, refit all the housing parts and outer panels that were removed.

Dimensions

Dimensions quoted in inches (millimeters)

a Electrical connection
Dimensions
b Exhaust duct
Dimensions

Possible voltage options

| Standard connection
---|---
Connection voltage| 3 AC 240/220/208 V*
Frequency| 50–60 Hz
Power rating| 12.4/10.5/9.4 kW
Fuse rating (on site)| 3×50 A
Minimum cross-section for connection cable| 4×AWG8

  • Transformer taps need to be set based on the electrical supply (voltage) provided.

Appliance Data

Appliance height, total 43 11/16″ (1110 mm)
Appliance width, total 87 15/16″ (2233 mm)
Appliance depth, total 25 5/8″ (651 mm)
Gross height (including packaging) 55 11/16″ (1414 mm)
Gross width (including packaging) 94 1/2″ (2400 mm)
Gross depth (including packaging) 33 7/8″ (860 mm)
Minimum wall distance, lateral 23 5/8″ (600 mm)
Minimum wall distance, rear 23 5/8″ (600 mm)
Roller length 65 3/8″ (1660 mm)
Roller diameter 3 13/16″ (250 mm)
Roller drive output 0.4 kW
Roller speed 1.9–5.7 rpm
Roller circumferential speed 1.5–4.5 m/min
Roller contact pressure 0.5 N/cm²
Net weight 309 lbs (189 kg)
Gross weight (including packaging) 342 lbs (214 kg)
Max. floor load in operation 1905 N
Emission sound pressure level 54 dB (A)
Sound power level 59.7 dB
Permissible ambient temperature range 40–105 °F (5–40 °C)
Fan air output 67 CFM (115 m³/h)
Fan power 0.11 kW
Exhaust duct 2 3/4″ (70 mm)
Maximum permitted pressure loss 0.014 PSI (100 Pa)

Customer Support

Please have the model and serial number of your machine available when contacting Technical Service.

Manufacturer | Fabricant : Miele & Cie. KG Carl-Miele-Straße 29, 33332 Gütersloh, Germany | Allemagne

Canada
Importer
Professional Division 161 Four Valley Drive Vaughan, ON L4K 4V8
Phone | Tél. : 1-888-325-3957
www.mieleprofessional.ca
professional@miele.ca
Miele Professional Technical Service | Service Technique
Phone: 1-888-325-3957
serviceprofessional@miele.ca

U.S.A
Miele, Inc.
National Headquarters 9 Independence Way Princeton, NJ 08540
Phone: 800-991-9380
www.mieleusa.com/professional
prosales@mieleusa.com
Technical Service & Support
Phone: 800-991-9380
proservice@mieleusa.com

Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals