Benchmark BSH100 My Block Mini Digital Dry Bath Instruction Manual

June 1, 2024
BENCHMARK

Benchmark BSH100 My Block Mini Digital Dry Bath

Specifications:

  • Temp. Range: [Provide temperature range]
  • Temp. Accuracy: [Provide temperature accuracy]
  • Temp. Increments: [Provide temperature increments]
  • Temp. Uniformity: [Provide temperature uniformity]
  • Block Construction: [Provide block construction details]
  • Environment: [Specify suitable environment for usage]
  • Dimensions: [Provide product dimensions]
  • Weight: [Specify product weight]
  • Electrical: [Provide electrical specifications]

Product Usage Instructions

Cautionary Notes:

  • CAUTION: Hot surfaces, especially on the block, can cause serious injury or burns.
  • CAUTION: Do not put water or liquids into the well as shock, serious injury, and death may occur.
  • CAUTION: Do not heat flammable or explosive substances as serious injury and death may occur.

Cleaning and Maintenance:
[Provide instructions on how to clean and maintain the product]

Service and Contact:
[Provide information on how to seek service and contact details for assistance]

FAQ:

  • Q: What should I do if the temperature accuracy seems off?
    A: If you notice a deviation in temperature accuracy, please refer to the user manual for calibration instructions or contact our customer service for assistance.

  • Q: Can I use the product in a humid environment?
    A: It is recommended to avoid using the product in excessively humid environments to prevent damage to the unit. Please ensure the environment is within the specified operating conditions.

Operations Manual
Item: BSH100
V1.0

Introduction

  • Thank you for purchasing the MyBlock™ Mini DryBath. Please read this manual thoroughly prior to operating the instrument.
  • The MyBlock Mini is an extremely compact digital dry bath (heat block). The instrument provides excellent temperature uniformity and accuracy for heating of tubes from 0.2ml up to 50ml. Each unit includes a convenient block lifter for removing blocks without having to wait until they have cooled.

Installation

Place the MyBlock Mini on a flat and level surface nearby an electrical outlet. It should not be near a heat source or in direct sunlight.

Operation

  • Attach the power cord and place the power switch into the on”-” position.
  • Press the “SET’ key and select the desired temperature using the up and down arrows.
  • The instrument will now quickly heat to the desired temperature. The right side of the display will read “NOT OK” until the desired temperature has been reached. The display will then read “OK”
  • Remove the clear cover and install the appropriate bock (purchased separately).
  • Once installed, load your samples into the block and attach the cover

CAUTION: Hot surfaces, especially on the block, can cause serious injury or burns.
CAUTION: Do not put water or liquids into the well as shock, serious injury and death my occur.
CAUTION: Do not heat flammable or explosive substances as serious injury and death may occur.

Specifications

  • Temp. Range: Ambient +5 to 80°C

  • Temp. Accuracy: +/- 0.5°C

  • Temp. Increments: 0.1°C

  • Temp. Uniformity: +/- 0.2°C

  • Block Construction: High Grade Aluminum

  • Environment: 4°C to 35°C

  • Dimensions: 4.4 x 5.9 x 4 in.
    11.2 x 15 x 10 cm

  • Weight: 1.2 lbs / 3kg

  • Electrical: 120V to 240V, 50-60 Hz

Cleaning and Maintenance

  • The aluminum blocks can be removed for cleaning by using the included block lifter. Once removed, the blocks can be cleaned with isopropyl alcohol or can be sterilized in an autoclave at 121 °C for 20 minutes.
  • The instrument can be cleaned with a damp cloth or isopropyl alcohol.

Service and Contact

In the event that service or technical support is required, please contact Benchmark Scientific by phone at 1-908-769-5555 or by email at [email protected] .Benchmark-BSH100-My-Block-Mini-Digital-Dry-Bath-01

Temperature calibration

  1. Power on the Mini Dry Bath, make sure that the temperature is less than 35C
  2. Insert a tube filled with water or oil into one of the tube wells.
  3. Insert a 1hermometer (wi1h accuracy of at least 0.1C) into 1his tubeBenchmark-BSH100-My-Block-Mini-Digital-Dry-Bath-02
  4. To enter the calibration mode press the Up and Down keys simultaneously (the temperature begins to rise to the first calibration point, 40C)
  5. Wait 15 to 20 minutes and read teh temperature shown on the thermometer. If the temperature differs, use the up and down keys to change the temperature in teh display to match teh temperature shown on the thermometer and press teh “SET” key.
  6. The temperature will now rise to the second calibration point of 80C.
  7. Follow the same instructions for calibration point 2 and press the “SET” button once completed.

The calibration is now complete and the dry bath enters back into the standard operating mode.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BENCHMARK User Manuals

Related Manuals