nVent 42U RDHX RackChiller Pro Hoses Kit Without Sensors User Manual

June 1, 2024
nVent

nVent 42U RDHX RackChiller Pro Hoses Kit Without Sensors

nVent-42U-RDHX-RackChiller-Pro-Hoses-Kit-Without-Sensors-
PRODUCT

Product Information

Specifications:

  • Product Name: RackChiller Pro
  • Model: SCHLAUCHSET OHNE SENSOREN (Hoses Kit without Sensors)
  • Manufacturer: nVent
  • Product Code: 60630-533_BET Rev.B

Description:

The RackChiller Pro is a cooling system designed to maintain optimal temperatures for various equipment in a rack setup. The SCHLAUCHSET OHNE SENSOREN model comes with hoses but without sensors.

Features:

  • Top mounting for easy installation
  • Color-coded components for easy identification (Blue for input, Red for output)
  • Durable construction

Product Usage Instructions

Mounting:

  1. Ensure the RackChiller Pro is placed in a suitable location within the rack setup.
  2. Use the provided mounting hardware to secure the cooling system in place at the top of the rack.

Connection:

  1. Connect the Blue hose (input) to the water source or cooling unit.
  2. Connect the Red hose (output) to the equipment requiring cooling.

Power:

  1. Ensure the power supply is connected to the RackChiller Pro.
  2. Follow any additional power-related instructions provided with the cooling system.

Maintenance:

  1. Regularly check hoses for leaks or damage.
  2. Clean the system periodically to ensure efficient operation.

FAQ

Q: Can I use this cooling system without sensors?

  • A: Yes, the RackChiller Pro SCHLAUCHSET OHNE SENSOREN model can function effectively without sensors, relying on manual input/output connections.

Product Overview

Note

  • Tightening torques are given with a tolerance of ±15% unless otherwise stated.
  • Only qualified and specialized personnel are authorized to make the connections
  • For hinges on right side, the assembly must be symmetrical
  • The instructions are illustrated with the bottom water connection. If the water connection is from the top, the installation must be symmetrical.
  • The instructions are illustrated with the lower water connection. For the top water connection, the following parts must be swapped: the exchanger plugs and coupler are fitted at the bottom by default (for a water inlet at the top). if the water inlet is at the bottom, the parts must be dismantled at the bottom and reassembled symmetrically at the top:***

nVent-42U-RDHX-RackChiller-Pro-Hoses-Kit-Without-Sensors-FIG
\(1\)

Parts

nVent-42U-RDHX-RackChiller-Pro-Hoses-Kit-Without-Sensors-FIG
\(2\)

Installation Instruction

nVent-42U-RDHX-RackChiller-Pro-Hoses-Kit-
Without-Sensors-FIG \(3\)

Adjust the length of the hoses between the 2 fixing clamps as short as possible, without reducing the opening by 90°.

nVent-42U-RDHX-RackChiller-Pro-Hoses-Kit-Without-Sensors-FIG
\(5\) nVent-42U-RDHX-
RackChiller-Pro-Hoses-Kit-Without-Sensors-FIG \(6\) nVent-42U-RDHX-RackChiller-Pro-Hoses-Kit-Without-Sensors-
FIG \(7\)