SEWOSY EF300ENCCTC Mortise Electromagnetic Locks Installation Guide
- June 1, 2024
- SEWOSY
Table of Contents
SEWOSY EF300ENCCTC Mortise Electromagnetic Locks
Product Information
Specifications
- Weighs 2 kg
- Operating Voltage: 12V DC or 24V DC (-15% / +20%)
- Current Consumption: 480 mA at 12V DC, 240 mA at 24V DC
- Power Consumption: 6W
- Maximum Theoretical Holding Force: 300 DaN
Product Usage Instructions
General Installation Instructions
- Use this equipment only for an adapted application.
- The manufacturer cannot be held responsible for possible damage caused when usual security requirements are not fulfilled.
- Mounting, maintenance, and repair must be carried out by skilled and authorized staff.
Connection
12/24V DC Connection:
- Contacts: Dry contacts
- Potential-free Contact: Potential-free contact
Attention – Caution:
- Make sure to observe correct polarity.
- Use correct input voltage as specified.
- Check jumper settings before connecting the lock to its power supply.
- Incorrect polarity, wrong input voltage, or wrong jumper position may damage the product. These failures are not covered by the product warranty.
- Check for perfect alignment between the armature plate and magnet.
FAQ
Q: What should I do if the product is damaged due to incorrect
installation?
A: The manufacturer cannot be held responsible for damage caused by
incorrect installation. Always ensure installation is carried out by skilled
and authorized personnel.
Q: Can I use a different voltage than specified?
A: No, using a different voltage than specified may damage the product
and void the warranty. Always use the correct input voltage.
EF30035ENC CA – EF30035ENCCTC CA
Maximal theoretical holding forces for implementations fulfi lling optimal installation conditions
PARTS
GENERAL INSTALLATION INSTRUCTIONS
MONTAGE INLICHTINGEN VOOR INSTALLATIE
- Use this equipment only for an adapted application.
- The manufacturer cannot be held responsible for possible damage caused when usual security requirements are not fulfi lled.
- Mounting, maintenance and repair must be carried on by a skilled and authorized staff.
INSTALLATION DIAGRAMS
Insert the rubber washer (j) between the steel washers (i) and do not screw too tighltly to keep the armature plate slightly loose.
DIMENSIONS
RACCORDEMENT CONNECTION
Caution
-
Make sure to observe correct polarity.
-
Use correct input voltage as specifi ed.
-
Check jumper settings before connecting the lock to its power supply.
Incorrect polarity, wrong input voltage or wrong jumper position may damage the product.
These failures are not covered by the product warranty. -
Check for perfect alignement between armature plate and magnet.