SEWOSY EXT200CTC Mounted Exterior Suction Installation Guide
- July 26, 2024
- SEWOSY
Table of Contents
INSTALLATION INSTRUCTIONS
SURFACE ELECTROMAGNETIC LOCK
ST_EXT200CTC_RANGE_E_110921
EXT200CTC + Accessoires
| | | | | | | |
---|---|---|---|---|---|---|---|---
EXT200CTC| 1,5 kg| 12V DC
ou-or-oder-of
24V DC
-15 /+20 %| 500 mA
ou-or-oder-of
250 mA| 6 W| 180 DaN
(*)| REED
24V DC / 1 A
(FRANCE : T.B.T.S.)| – 10° C
→
+ 55° C| 67
(*) Maximal theoretical holding forces for implementations fulfilling optimal installation conditions
BILL OF
MATERIAL|
---|---
EXT200CTC
GENERAL INSTALLATION INSTRUCTIONS
- Use this equipment only for an adapted application.
- The manufacturer cannot be held responsible for possible damage caused when usual security requirements are not fulfilled.
- Mounting, maintenance and repair must be carried on by a skilled and authorized staff.
DIMENSIONS
OPTIONAL ACCESSORIES
INSTALLATION DIAGRAMS
Insert the rubber washer (l) between the steel washers (k) and do not screw too tightly to keep the armature plate slightly loose.
CONNECTION
12 VDC | 24 VDC | CONTACT |
---|---|---|
YELLOW-GREEN-BROWN-WHITE | YELLOW-GREEN-BROWN-WHITE | |
WHITE |
Attention:
-
Use correct input voltage as specified.
Wrong input voltage may damage the product.
This failure is not covered by the product warranty. -
Check for perfect alignment between armature plate and magnet.
13b rue Saint-Exupéry CS20152 F-67503 HAGUENAU CEDEX
****+33 (0)3 90 59 02 20 +33 (0)3 90 59 02 19
Technical changes reserved!