CPi D263000011 Tube Coin Changer Instruction Manual
- June 1, 2024
- CPI
Table of Contents
CPi D263000011 Tube Coin Changer
Components
Key coin changer components are identified below.
No. | Item | Description |
---|---|---|
1 | Coin return | Press to reject a coin and open the validator door. |
2 | Validator latch | Pull to remove the validator assembly. |
3 | Man machine interface (MMI) | Use this screen and keypad to interact with |
and update the coin changer.
4| Diagnostic LEDs| Displays the status of the coin changer with red, amber,
and green LEDs.
5| Cassette| Stores coins for dispensing as change.
6| Dispenser| Dispenses coin returned as change.
7| Cassette release tab| Lift and pull to remove cassette from main housing.
8| Micro USB port| Connect to a PC or USB memory stick for reading audits,
changing settings, and updating firmware.
Keypad
The MMI screen displays messages related to current operational status and menu selections. Always follow on-screen messages. See menu navigation tips below.
No. | Description |
---|---|
1 | Display |
2 | Press keys A-F to navigate user menus. See Symbols for details. Keys A-F |
are also used to dispense coins from corresponding tubes when in normal
operating mode.
3| Move left
4| Move right
5| Scroll up
6| Scroll down
7| Previous page
8| Next page
9| Press to access Service and Setup menus. Press once to display previous
menu.
Hold for 3 seconds to return to home screen.
10| Diagnostic LEDs: red, amber, and green.
Diagnostic LEDs
Diagnostic LEDs indicate coin changer statuses.
Color | Sequence | Description |
---|---|---|
On | Unit is properly working | |
Cycles 5 times | Boot-up sequence | |
1 flash | Coin accepted | |
2 flashes | Coin rejected | |
3 flashes | Rejected coin was inhibited on unit | |
Slow flash after pressing | Unit is in Service or Setup menu | |
Fast flash after pressing | Audit processing or firmware update | |
On | Unit inhibited by VMC | |
1 flash | Coin return lever active | |
2 flashes | Validator error | |
3 flashes | Cassette error | |
4 flashes | Dispenser error | |
Alternating | Unit failure. Replacement required. |
Symbols
Symbols on the screen indicate coin changer statuses.
Symbols | Description |
---|
| Menu navigation
| Unit is OK
| Unit requires attention
| Unit has fatal error. Replacement required.
| Unit is connected via USB to PC
| Unit is connected to USB stick
| Error
Service menu
Press
to view Service menu options.
Service menu navigation | Description |
---|---|
A | Start float operation |
D | Configure tube denominations for custom cassette |
D + 3 letter keys | Enter 3-digit code for predefined cassette (code is located |
on front of cassette)
E| Access Setup menus
| Read basic audit on display. Audit counters and tube contents are displayed
in sequence. Each value will display for 3 seconds before showing End of Audit
message.
Setup menu
Press E to access the Setup menus.
Item | Description |
---|---|
Float Mode and Target Values |
- Change float mode, target levels, or target value
- Create a snapshot
Change Management| Adjust float levels and mix of coin paid as change
Machine Options| Select and change settings related to machine interface in
use
Coin Config|
- Enable/disable individual coins
- Select standard or high-security coin acceptance
- Select teach and edit token settings
- Set dual currency exchange rates
Audit Config| Set audit-related settings
General|
- Save current settings
- Calibrate tubes
- Miscellaneous settings for items such as: currency for change accepted, display, and keypad
Error Log| View and reset recent errors
Test| Run tests to confirm correct operation
Language| Change display language
Cassette configuration
Two methods for configuring the coin changer cassette are outlined below.
The cassette must be empty before configuring or recalibrating.
Configuration method | Steps |
---|---|
Cassette code | To change the cassette: |
- Press , followed by CASSETTE.
- Enter the required cassette code and press SAVE. Follow the custom cassette steps below if the code is not recognized.
- Press START to calibrate the empty cassette when prompted.
Individual tubes or custom cassette| Tubes are coin-specific. Accepted coin size is printed on the side of the tube.
To change individual tubes or create a custom cassette:
- Press , followed by CASSETTE.
- Use keys A-F to select the tube position.
- Select the denomination for the tube.
- Press SAVE to store the setting.
- Press when all tubes are programmed.
- Press START to calibrate when prompted.
Installation
To install the coin changer:
-
Remove the coin changer from packaging. If it was damaged during shipping, go to CranePI.com/Support to locate a customer service contact near you.
Review the operating voltage on the label that is displayed on the left side of the device (when looking at the front of the coin changer). -
Turn off power to the vending machine.
-
Lift the yellow latch on the top right of the coin changer and tilt the validator assembly forward to access the coin changer mounting holes. The cassette does not need to be removed.
-
Hang the coin changer on the vending machine’s mounting screws, ensuring the unit is level. See Alignment
-
The lower mount (5a) can be difficult to see through the device. Hanging the coin changer from the top 2 screws (5b and 5c) first will help to locate the lower mount.
-
Tighten the mounting screws, if necessary, being careful not to over-tighten. Close the validator assembly. The lower mount is difficult to access with a large screwdriver.
-
Remove the cassette if coins will be directly inserted into tubes. Lift it by the handle and pull toward you.
-
Fill the cassette with coins, ensuring coins are inserted into the proper tubes.
-
Return the filled cassette to the coin changer and ensure it is correctly seated.
-
Restore power to the vending machine.
Alignment
After installing the coin changer:
- Ensure there is a small gap (1a) of 2-4 mm (0.08-0.16 in) between the reject lever on the vending machine (1b) and the return lever on the coin changer (1c).
- Press the coin return lever on the vending machine door. Confirm that it fully opens the validator door on the coin changer, and then smoothly returns and fully closes.
- Check alignment of the coin entry chute on the vending machine, ensuring it does not impede operation of the validator door on the coin changer.
- Align, adjust, and test as necessary to ensure coins are properly routed before continuing.
Coin entry chute size and alignment
Letter | Measurement or description |
---|---|
A | Reference mounting hole axis |
B | 39 mm (1.54 in) |
C | 36.5 mm (1.44 in) |
D | 3.5 mm (.14 in) |
E | Diameter = 33 mm (1.3 in) |
F | Coin entry chute |
G | 3 mm (.12 in) |
H | 50 mm (1.97 in) |
I | 46.5 mm (1.83 in) |
J | Maximum coin thickness = 3.5 mm (.14 in) |
Compliance
Gryphon coin changer meets domestic and international standards for emission, safe product design, and environmental regulations. Contact your CPI service representative for details.