PARADOX SP738 Wiring Uplinks Cellular Communicators User Manual
- June 1, 2024
- Paradox
Table of Contents
PARADOX SP738 Wiring Uplinks Cellular Communicators User Manual
CAUTION:
- It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
- Do not route any wiring over circuit board.
- Full panel testing, and signal confirmation, must be completed by the installer
NEW FEATURE: For 5530M Communicators, the status of the panel can be
retrieved not only from the status PGM but now also from the Open/Close
reports from the dialler. Therefore, wiring the white wire and programming of
the status PGM of the panel is optional.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the
initial pairing procedure.
Wiring the 5530M communicators to Paradox SP728/ SP73
Programming the Paradox SP728/ SP738 Alarm Panel via the Keypad
Enable Contact ID reporting:
** LED indication on Keypad| Keypad Entry| Action Description
---|---|---
“Ready” steadygreen| Enter, 282828| To enter programming mode (SP738 – 383838)
“Enter” flashing red| 086| To go to Reporting options toggle menu
“Enter” steady red| 2nd,1, 7, 11,12| Press the respective buttons until 2nd
and 1 are OFF/DIM (TLM disabled), 7 – ON/LIT (to enable DTMF) and 11 –
OFF/DIM, 12 – ON/LIT (Stay – off, Away – on)
“Enter” flashing red| Enter| To go back
“Enter” flashing red| 088| To go to EOL toggle menu
“MEM” steady red| MEM, Enter| Press MEM button until it’s OFF/DIM (all
zones without sensors mustbe closed with resistors), Enter to go back
“Enter” flashing red| 038| To go to Communication format
2ND flashing red| 0,0| To enable automatic codes Contact ID reporting for
Phone 1 and 2
“Enter” flashing red| 704| To go to Phone number input
“Enter” steady red| 123456,Enter, Enter| To set the desired phone number
(123456 is an example)
“Enter” flashing red| 708| To go to account number menu
“Enter”** steady red| 1234,Enter, Enter| To set the desired account number
(1234 is an example)
“Enter” flashing red| Enter| To exit programing mode
Enable keyswitch arm/disarm and status output:
LED indication on Keypad | Keypad Entry | Action Description |
---|---|---|
“Ready” steadygreen | Enter, 282828 | To enter programming mode (SP738 – |
- “Enter” flashing red| 086| To go to Reporting options toggle menu
“Enter” steady red| 2, 3, Enter| Press the respective buttons until 2 is OFF/DIM (to enable Full Arming) and 3 – ON/LIT (to enable Momentary Keyswitch), Enter to go back
“Enter” flashing red| 039| To go to PGM types menu
“Enter” steady red| 2nd, 2nd| To enable normally open output (PGM)
“Enter” flashing red| 040| To go to PGM1 1st options menu
“Enter” steady red| 29| To enable output when system is armed
“Enter” flashing red| 042| To go to PGM1 3rd options menu
“Enter” steady red| 2nd, 3| To enable output when system is armed
“Enter” steady red| Enter, Enter| To exit programming mode