ARITEC EV669 Ceiling Mount Detector Instruction Manual

June 1, 2024
ARITEC

ARITEC EV669 Ceiling Mount Detector

ARITEC-EV669-Ceiling-Mount-Detector-PRODUCT

Product Information

Specifications

  • Made in: Netherlands
  • Det. pattern: 180° or 360°
  • Mounting Heights: 2.5 to 5.0 m (8 ft. 2 in. to 16 ft. 5 in.)
  • Control Voltage: Low (0 Volt) or High (12 Volt)
  • Processing: Bi-curtain or Standard-4D

Product Usage Instructions

Mounting Instructions

  1. Lift off the mounting plate from the ceiling.
  2. Fasten the mounting plate to the ceiling at the desired height within the specified range.
  3. Mount the sensor module to the mounting plate using the provided screw.
  4. The curtain directions are indicated on the mounting plate, with curtain no. 5 being the centre curtain.

DIP Switch Settings

  • Switch 1: Programming the Control Voltage (CV)
    • On: Inversed logic for low voltage requirement.
    • Off: Standard logic for high voltage requirement (factory default).
  • Switch 2: Programming the LED
    • On: Enables LED continuously (factory default).
    • Off: LED controlled by Walk test and Latch input.
  • Switch 3: Programming the processing On: Enables Bi-curtain processing for harsh environments (factory default).

FAQ

  • Q: What is the purpose of Bi-curtain processing?
  • A: Bi-curtain processing is designed to reduce false alarms by requiring intruders to be detected in two separate curtains before triggering an alarm.
  • Q: What is the recommended mounting height for optimal performance?
  • A: The recommended mounting heights are between 2.5 to 5.0 meters (8 ft. 2 in. to 16 ft. 5 in.) for best sensitivity and coverage.

Installation Instructions

Description

  • The EV660 series includes models EV666-D with Form C relay, and EV669 with Form A relay.
  • These are ceiling-mount PIR detectors with 360° coverage.

WARNING

ARITEC-EV669-Ceiling-Mount-Detector-FIG-1

Mounting the detector

  • Install the detector so that the expected movement of an intruder will be across the field of view. This is the direction best detected by PIR detectors. See Figure 7

ARITEC-EV669-Ceiling-Mount-Detector-FIG-7

Avoid possible false alarm sources such as

  • Direct sunlight onto the detector
  • Heat or cold sources in a field of view (heaters, air conditioning, radiators, etc.)
  • Moving objects in the field of view (fans, pets, etc.)
  • Obscuring the detector field of view with large objects, such as furniture

Increase of mounting heights beyond the specified (2.5 to 5.0 m) range will reduce sensitivity.

Note: The arrow (Figure 2, item 4, and Figure 7) indicates the centre curtain direction and the active direction when switch 4 is set to ON.

Mounting instructions

ARITEC-EV669-Ceiling-Mount-Detector-FIG-2

  1. Lift off the mounting plate (item 1) as shown.
  2. Fasten the mounting plate to the ceiling in the required position using mounting holes (item 3).
  3. Ensure the mounting height is 2.5 to 5.0 m.
  4. The detection pattern can be adjusted by up to ±15° (max 30°) by rotation of the mounting plate prior to tightening the screws.
  5. Strip the cable for 5 cm and pull it through the cable entry hole (item 5) and strain relief.
  6. Wire the detector select the appropriate processing options (see “DIP switch settings”) and mount the sensor module (item 8).
  7. To mount the sensor module to the mounting plate use the screw (items 6 and 7), which is placed for transport in the mounting plate

The curtain directions 1 to 9 clockwise (item 2) are indicated in the mounting plate (curtain no. 5 is the centre curtain).

DIP switch settings

Switch 1: Programming the Control Voltage (CV)ARITEC-EV669-Ceiling-
Mount-Detector-FIG-6

  • On: Inversed logic, a low voltage is needed to enable the Walk test and Latch functions.
  • Off: Standard logic, a high voltage is needed to enable the Walk test and Latch functions (factory default).

Switch 2: Programming the LED

  • On: Enables the LED on the detector at all times (factory default).
  • Off: Puts the LED under the control of the Walk test and Latch input.

Switch 3: Programming the processing

  • On: Enables Bi-curtain processing designed for harsh environments (factory default).

Note: Bi-curtain is used to reduce the possibility of false alarms. It looks for signal verification and requires the intruder to be seen in two curtains for an alarm.
Off: Provides the standard 4D processing.
Note: This mode must be used in EN 50131-compliant installations.

Switch 4: Programming the detection pattern

  • On: Provides a 180° field of view for special applications.
  • Off: Gives the normal 360° field of view (factory default).

Alarm memory
Note: First set the control voltage (CV) by switch 1 (see Figure 3). For example: Switch 1 = On, then CV = 0 V = Low.
Connect CV to terminal 9 when the system is armed. When the system is disarmed, disconnect the CV. If an alarm has occurred during the armed period, a flashing LED indicates the detector or detectors that gave the alarm. Reapplying the CV (rearming the system) will reset LED indication and memory.

ARITEC-EV669-Ceiling-Mount-Detector-FIG-3

Remote enable/disable of the walk test LED
To walk test the detector, the CV to terminal 9 (Latch) must be disconnected. Connect CV to terminal 10. The detector’s LED will now light and go out again as the alarm relay opens and closes, making possible walk testing.

Notes

  • Enabling the walk test will not clear alarm memory. After disarming the system after an alarm, you may switch to walk test.
  • When you switch back out of walk test, the indication of memorized alarms will re-appear.
  • Only when CV is reapplied to terminal 9 (for example, the system is rearmed) will LEDs and memory be cleared.
  • To enable the walk test LED without a remote CV input, connect a link between terminals 2 and 10.

Access to the mirror inside the sensor module

  • This access is only required when masking individual curtains.
  • Unfasten the screw (Figure 2, item 9) and open the sensor module (item 8). The two mirrors are accessible now.

Selecting the coverage patterns

  • Mask the appropriate mirror curtains with the adhesive labels provided and reassemble the sensor module.
  • For example: see Figure 4 for the mirror curtain coverage pattern corresponding to curtains 4 and 8 masked.

Specifications

  EV666- D EV669
Input power 7 to 15 V (12 V nom.)
Peak to peak ripple 2 V max. (at 12 V )
Current consumption: Normal operation Alarm ****

9 mA

15 mA max.

| ****

9 mA

15 mA max.

Target speed range| 0.3 to 3.0 m/s
Alarm output| 100 mA at 28 V Form C switchover contact (see Figure 5)| 100 mA at 28 V Form A (NC), voltage-free relay (see Figure 5)
Alarm time| 2.5 s min.
Tamper output| 100 mA at 28
Temperature limit| −10 to +55°C
Relative humidity| 93% max.
Size| Ø 138 x 75 mm
Weight| 190 g
Number of zones| 18
Max. detection range| 10 m radius; 20 m diameter
Housing meets (with sealed cable entry)| IP30 IK04

ARITEC-EV669-Ceiling-Mount-Detector-FIG-5

Regulatory Information

Manufacturer| Carrier Fire & Security Americas Corporation Inc. 13995 Pasteur Blvd

Palm Beach Gardens, FL 33418, USA

Authorized EU manufacturing representative: Carrier Fire & Security B.V.

Kelvinstraat 7, 6003 DH Weert, Netherlands

---|---
Product warnings and disclaimers


| THESE PRODUCTS ARE INTENDED FOR SALE AND INSTALLATION BY QUALIFIED PROFESSIONALS. CARRIER FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS.
 |  | For more information on warranty disclaimers and product safety information, please check https://firesecurityproducts.com/policy/product- warning/ or scan the QR code.
---|---|---
 |  |
 |  |
Certification|  | EV666-D, EV669: EN 50131-2-2, Security

Grade 2, Environmental Class II.

Tested and certified by the Dutch testing and certification body Telefication.

European Union directives|  | Carrier Fire & Security hereby declares that this device complies with the applicable requirements and provisions of the Directive 2014/30/EU and/or 2014/35/EU. For more information see firesecurityproducts.com or www.aritech.com.
REACH|  | The product may contain substances that are also Candidate List substances in a concentration above 0.1% w/w, per the most recently published Candidate List found at ECHA website.

Safe use information can be found at https://firesecurityproducts.com/en/content/intrusi on-intro

|  | 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: recyclethis.info
Product Documentation

|  | Please consult the following web link to retrieve the electronic version of the product documentation.

This link will guide you to the EMEA regional contact page. On this page, you can request your login to the secured web portal where all manuals are stored.

https://firesecurityproducts.com/en/contact

Contact information

Declaration of Conformity

  • EV669 / EV666-D series is suitable for use in alarm systems designed to comply with PD6662 at security grade 2 and environmental class II.
  • They conform to the relevant parts of the following standards:
  • EN 50131-1: Alarm systems-Intrusion systems Part 1: System requirements
  • EN 50131-2-2: Alarm systems. Intrusion systems. Intrusion detectors. Passive infrared detectors
  • EV669 / EV666-D have been tested and certified to EN 50131-2-2, EN 50131-1 for security grade 2, environmental class 2, by the Dutch testing and certification body Telefication B.V.