F F BIS-413M 24V Electronic Bistable Impulse Relay User Manual

June 13, 2024
F F

F F BIS-413M 24V Electronic Bistable Impulse Relay

F-F-BIS-413M-24V-Electronic-Bistable-Impulse-Relay-
fig-1

Product Information

  • F&F Filipowski sp. j. Konstantynowska 79/81, 95-200 Pabianice, POLAND
  • Phone/Fax : (+48 42) 215 23 83 / (+48 42) 227 09 71
  • Website: www.fif.com.pl
  • Email: biuro@fif.com.pl
  • Product Name: BIS-413M 24V
  • Description: Bistable relay with timing switch and “memory contact position”
  • Purpose: Electronic bistable pulse relay BIS-413M allows switching on or off the lighting or other device from several different points by parallel connected, momentary (bell) control switches.

Functioning

  1. The relay has the feature of the so-called “memory of the contact position”, which means when the power supply is switched back on, the relay will be restored to the state it was in when the power supply was switched off.
  2. Mounting:
  3. Disconnect the power supply.
  4. Fix the relay on a rail in the control box.
  5. Connect the power wires to terminals 1-3, any polarity for AC.
  6. BIS-413M 24V is not compatible with backlit buttons.

Wiring Diagram

Technical Data

Power Supply| Contact Maximum Load Current (AC-1)| Activation Delay Adjustment Time| Power Indication| Signalling Activation| Power Consumption (Standby/On)| Terminal Tightening Torque| Working Temperature| Dimensions| Mounting| Ingress Protection
---|---|---|---|---|---|---|---|---|---|---
24V| –| –| Red LED| –| 0.15 W / 0.8 W| –| –| –| TH-35 Rail| IP20

Power Table

Tungsten Halogen Fluorescent Energy-Saving LED
2000W 1250W 1000W 500W
250W

Warranty

The F&F products are covered by a warranty of 24 months from the date of purchase. The warranty is effective only with proof of purchase. Please contact your dealer or directly with us for further assistance.

CE Declaration

F&F Filipowski sp. j. declares that the device is in conformity with the essential requirements of The Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/UE. The CE Declaration of Conformity, along with the references to the standards in relation to which conformity is declared, can be found at www.fif.com.pl on the product page.

DISPOSAL

Do not dispose of this device in the trash along with other waste! According to the Law on Waste, electro coming from households free of charge and can give any amount to up to that end point of collection, as well as to store the occasion of the purchase of new equipment (in accordance with the principle of old-for-new, regardless of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the environment and human health.

Purpose

Electronic bistable pulse relay BIS-413M allows switching on or off the lighting or other device from several different points by parallel connected, momentary (bell) control switches.

Functioning

  • The receiver is switched on after a current pulse caused by pressing any momentary (bell) button connected to the relay. The receiver is turned off after the next impulse or automatically after the set off time. A longer pressing of the momentary but-ton, lasting at least 2 seconds, turns on the relay permanently. The relay will be turned off only after pressing the momentary button again (or after a power supply failure). The supply voltage is indicated by the illumination of the green LED marked as U. Switching the relay on and the countdown to automatic switch-off is signalled by the blinking of the red LED. Permanent switching of the relay is signalled by continuous lighting of the red LED.
  • The relay has the feature of the so-called „memory” of the con-tact position, which means when the power supply is switched back on, the relay will be restored to the state it was in when the power supply was switched off.

Mounting

  1. Disconnect the power supply.
  2. Fix the relay on a rail in the control box.
  3. Connect the power wires to terminals 1-3, any polarity for AC voltage and for DC voltage: connect „+” to terminal 3, „–” to terminal 1.
  4. Momentary switches connected in parallel connect to terminal 6 and the wire, to which terminal 3 is connected.
  5. Powered receiver connect in series to terminals 11-12.
  6. Set the switch-off time with the potentiometer.

Contact configuration

Wiring diagram

  • 1-3 relay power supply 9÷30 V AC/DC
  • 6 control input
  • 10 output – break contact (passive)
  • 11 input – COM power supply contact
  • 12 output – closing contact (active)

Technical data

  • power supply 9÷30 V AC/DC
  • contact separated 1×NO/NC
  • maximum load current (AC-1) 16 A
  • activation delay 0.1÷0.2 s
  • adjustment time 1÷12 min.
  • power indication green LED
  • signalling activation red LED
  • power consumption standby on
    • 0.15 W
    • 0.8 W
  • terminal 2.5 mm² screw terminals
  • tightening torque 0.4 Nm
  • working temperature -25÷50°C
  • dimensions 1 module (18 mm)
  • mounting on TH-35 rail
  • ingress protection IP20

Power table

Table for loads supplied with 230 V AC:

The above data are indicative and will heavily depend on the design of a specific receiver (that is especially important for LED bulbs, energy-saving lamps, electronic transformers and pulse power supply units), switching frequency and operating conditions.
For more information visit: www.fif.com.pl.

Warranty

The F&F products are covered by a warranty of the 24 months from the date of purchase. Effective only with proof of purchase. Contact your dealer or directly with us.

CE declaration

  • F&F Filipowski sp. j. declares that the device is in conformity with the essential requirements of The Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/UE.
  • The CE Declaration of Conformity, along with the references to the standards in relation to which conformity is declared, can be found at www.fif.com.pl on the product page.

ABOUT COMPANY

  • F&F Filipowski sp. j.
  • Konstantynowska 79/81, 95-200 Pabianice, POLAND
  • phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
  • www.fif.com.pl;
  • e-mail: biuro@fif.com.pl

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>