Safety Instruction

Symbol Description
To avoid personal injury or property damage, be sure to observe the contents below.

  • The following symbols are used to illustrate what you should observe.
  • Indicates prohibition
  • Indicates the actions that need to be subject to instructions

People Restricted or Prohibited from Use

Important Information

  • This product cannot be used under any of the following circumstances without the prior consent of your doctor.

  • The appllance has a heated surface. Persons insensitive to heat must be careful when using the appliance.

  • This appliance Is not Intended for use by persons (Including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

  • Children should be supervised to ensure that they do not play with the appliance. If the supply cord Is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.

  • This appliance contains batteries that are only replaceable by skilled persons. Must be only supplied at safety extra low voltage corresponding to the marking on the appliance.

  • The occurrence of pregnancy, diabetic complications (e.g. neuropathy or retinal damage), pacemaker wearing, recent surgery, epilepsy or migraine, disc herniation, anterior vertebra, vertebrae detachment, or ankyloses of the vertebra, recent arthroplasty surgery or IUD, Kirschner wire or steel plate and other health-related Issues. These contraindications do not mean that you are not allowed to use the Product. It is recommended to consult your doctor before use.
    The underway research is about the impact of vibration training on specific

  • medical diseases. This stands a good chance of reducing the various contraindications mentioned above. The practice proves that under many circumstances, the incorporation of vibration training into a therapeutic regimen is also a form of therapy, but it must be done at the suggestion or In the company of a doctor, expert or physical therapist.

The product is not allowed to be used by the following groups/under the following circumstances

  • It is forbidden for minors to use the product. If injured, it Is not allowed to use it.
  • Please consult your doctor before using it in case of muscle injury.
  • Do not use the device on a non-dry and non-clean skin surface. You can use this product with clothes on. Gentle press and move it on the skin for about 60 seconds per area.
  • Do not use the device on the part above the neck and with less muscle coverage. It is forbidden to use it on the bones. Under the circumstance of not causing pain or discomfort, only use the device on the soft tissues of the body.
  • Do not use the device in the occurrence of bruising, pain or discomfort.
  • Do not place any object In the vent of the device.
  • Do not immerse the device in water, or let water get into the vent of the device. Do not put the device into the fire or place it near the fire source.
  • Do not drop the device intentionally.
  • Do not charge the device with a charger with a voltage exceeding 9V. Disassembly of the device in any way is prohibited.
  • Do not place your fingers, hair or other body parts near the shaft or back of the massage head due to the risk of being clamped.
  • It is forbidden for people who are unable to express their will or who cannot operate the machine themselves to use this Product.
  • Children are not allowed to use the product. Keep children away from it when using it.
  • Please stop Immediately when you feel lower back pain, dizziness, vomiting, palpitation and other abnormal body reactions during use.
  • This product is set for 10 minutes at a time. Do not use t for no more than 20 minutes each time. After each use, stop the device for 30 minutes to ensure the extension of its service life.
  • Do not use the product under the following circumstances:
    • When you are severely tired
    • Within one hour before and after meals
    • When you are drunk

Precautions for Use

  • Do not wear excessive clothes during use.
  • Keep away from liquid or heat sources.
  • Do not use any products other than the original binding charging base and DC charger. Must be only supplied at safety extra low voltage corresponding to the marking on the appliance.
  • Do not use the product during charging.
  • After charging, disconnect the power supply in time.
  • Stop the device Immediately if it cannot work properly or you feel abnormal.
  • Follow the instructions when using the product.
  • Before each use, carefully check whether the product can be used normally according to the operation instructions in this manual.
  • Do not load and ballast the power cord or cause damage to It.
  • Do not stand on the device or use the device as a toy to avoid accidents.
  • Do not disassemble, modify or repair the product by yourself.
  • Do not use the device if your body is wet.

Precautions for Maintenance

  • Be sure to disconnect the power supply before maintenance.
  • Do not drop the main unit and its charging base. Do not strike it strongly.
  • Do not pour water on the product.
  • Do not use the product in a bathroom or places with high humidity.
  • Be sure to confirm whether the switch is normal in advance before it is used again if it has not been used for a long time.
  • Do not use volatile oil, thinner, alcohol, strong alkaline detergent, bleach or other cleaning agents for maintenance.
  • The product is equipped with a simple shockproof facility and is suitable for air, railway, road and ship transportation. Keep away from rain and snow splashing, inversion and collision during transportation.
  • Keep out of reach of the children.
  • Make the device cool down before storing it.
  • Check the device for any sign of wear or damage regularly. If there is such a sign, or if the device has been misused, contact the supplier for maintenance before reuse.

Product Features

This product is available for relaxing the tense muscles and releasing post- exercise soreness and fatigue by massaging the soft tissues of the body with high frequency. A variety of massage heads can be combined to massage muscles all over the body. Equipped with a portable storage bag, it is easy to carry out.

Components

PHILIPS-PPM7303-Mini-Massage-Gun-Fig- \(1\)PHILIPS-
PPM7303-Mini-Massage-Gun-Fig- \(2\)

How to Use

Preparations Before Use

  1. Check if the device and its accessories are complete.
  2. Remove the pendants and decorations during use, to avoid affecting the massage part.
  3. Install the massage head in place.

Installation

According to the message demand, insert the appropriate massage head into the front round hole of the main unit, and then press it firmly to the end, as shown in the figure below, indicating that it is installed in place.

PHILIPS-PPM7303-Mini-Massage-Gun-Fig- \(3\)

The installation effect is shown in the figure below:

PHILIPS-PPM7303-Mini-Massage-Gun-Fig- \(4\)

Operation

  1. Start the device. Press and hold the operation button for 1 second to start the device, and then the device will enter Level O by default. Press the button once to increase one level, with a maximum of S levels. When it goes to Level 5, press the button to enter Level O again, and repeat in this way.
  2. Press and hold the operation button to switch off the device at any level.
  3. The device will automatically switch off after 10 continuous use for 10 minutes. Restart the device for use again.
  4. The massage head is suspended after being blocked. This is to protect the device against abnormal operation. Press the button to restart the device.

PHILIPS-PPM7303-Mini-Massage-Gun-Fig- \(5\)

Charging

  1. Before the first use, charge the device for 4 hours until it is fully charged.
  2. When charging, use the TYPE-C charging cable provided In the accessories and connect the end of the USB to the 5V2A output port of the charger;
  3. The LED lamp on the device Hashes regularly to display the battery’s remaining capacity, Indicating that it is being charged;
  4. The battery can be charged at any time and any power level. Do not start and use the device when charging;
  5. The battery needs to be charged when it is exhausted to less than 5% (the power indicator Hashes red).
  6. The fully-charged device can be operated for about average of 2-3 hours, depending on the working level and strength.

Indicator Description

PHILIPS-PPM7303-Mini-Massage-Gun-Fig- \(7\)

Maintenance

  1. Clean the surface of the device with a slightly wet towel and then dry it with a soft cloth.
  2. Put the device in the appropriate portable bag for storing or travelling.
  3. Store the device in a dry and well-ventilated place without corrosive gas.
  4. Clean and pack the device if it is not used for a long time. It is recommended to charge it every 1 month.
  5. This product is suitable for transportation by car, train, ship and aeroplane. During transportation, the product shall be fixed against violent vibration, collision, tumbling and falling, and shall be placed upward and be handled with care and rainproof.
  6. To protect the environment, do not discard it at random. Please discard each part according to their disposal methods.
    • During maintenance, the power cord must be unplugged, but do not unplug it with wet hands.

Disposal
The lithium-ion battery used in this product is a valuable resource that can be recycled. Take out the lithium-ion battery when it is used up and discarded, and then hand it over to a professional institution that can recycle the rechargeable batteries for disposal.

Battery removal:
Pry open the bottom of the main unit, and then remove the battery from the device (The battery cannot be replaced by users arbitrarily):

  • The battery must be taken out from the product before the device is discarded;
  • The product must be powered off when the battery is removed;
  • The battery shall be disposed of safely.

Troubleshooting

This chapter lists the most common problems with the product. If the problems you encounter are not included in the following tables, please call our service hotline or contact the authorized service centre in your region.

PHILIPS-PPM7303-Mini-Massage-Gun-Fig- \(8\)PHILIPS-
PPM7303-Mini-Massage-Gun-Fig- \(9\)

Technical Parameters

PHILIPS-PPM7303-Mini-Massage-Gun-Fig- \(10\)

Service Guide for Product Warranty

Warranty and Service

  • If you need information or have any questions, please visit www.philips.com/support or contact the consumer service centre in your country/region. If there is no consumer service centre in your country/region, please contact your local distributor.
  • Within two years from the date of purchase, you will receive free warranty service for any damage caused by manufacturing process problems, or any damage to components under normal use conditions confirmed by our maintenance service personnel.

Warranty service excludes frequently replaced consumables, auxiliary equipment, shipping costs and door-to-door service. Please show proof of purchase to service personnel when servicing.

Warranty Card

PHILIPS-PPM7303-Mini-Massage-Gun-Fig- \(11\)