AL-KO TK 250 ECO Submersible Pump Instruction Manual
- June 3, 2024
- AL-KO
Table of Contents
- Instructions
- ABOUT THESE OPERATING INSTRUCTIONS
- PRODUCT DESCRIPTION
- Product overview on the (1)
- SAFETY INSTRUCTIONS
- INSTALLATION
- START-UP
- OPERATION
- MAINTENANCE AND CARE
- STORAGE
- DISPOSAL
- HELP IN CASE OF MALFUNCTION
- AFTER-SALES / SERVICE
- GUARANTEE
- EU DECLARATION OF CONFORMITY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AL-KO TK 250 ECO Submersible Pump Instruction Manual
Instructions
| TK 250 ECO
(Art. Nr. 113 593)| TS 400 ECO
(Art. Nr. 113 594)
---|---|---
| 250 W| 400 W
| 230 V AC/50 Hz| 230 V AC/50 Hz
| X 8| X 8
| 6 m| 5 m
| 6000 l/h| 8000 l/h
| 35 °C| 35 °C
| 3 mm| 30 mm
| 3,55 kg| 3,82 kg
ABOUT THESE OPERATING INSTRUCTIONS
- The German version is the original operating instructions. All additional language versions are translations of the original operating instructions.
- It is essential to carefully read through these operating instructions before start-up. This is essential for safe working and trouble-free handling.
- Always safeguard these operating instructions so that they can be consulted if you need any information about the appliance.
- Only pass on the appliance to other persons together with these operating instructions.
- Comply with the safety and warning information in these operating instructions.
Legends and signal words
DANGER!
Denotes an imminently dangerous situation which will result in fatal or
serious injury if not avoided.
WARNING!
Denotes a potentially dangerous situation which can result in fatal or serious
injury if not avoided.
CAUTION!
Denotes a potentially dangerous situation which can result in minor or
moderate injury if not avoided.
IMPORTANT!
Denotes a situation which can result in material damage if not avoided.
NOTE
Special instructions for ease of understanding and handling.
PRODUCT DESCRIPTION
Various models of pumps are described in these operating instructions. Identify your model from the identification plate.
Product overview on the (1)
No. | Component |
---|---|
1 | Handle |
2 | Connection cable |
3 | Float switch cable |
4 | Pump housing |
5 | Combination adapter |
6 | Connection elbow |
7 | Suction slots |
8 | Float switch |
Function
The pump draws the conveying medium directly through the suction slot and feeds it to the pump outlet. It is switched on and off using a float switch.
Thermal protection
The pump is fitted with a thermal protection switch which switches the motor off in the event of overheating. After a cooling-down phase of approx. 15 – 20 minutes the pump switches on again automatically.
Operate the pump only if it is fully immersed.
Designated use
The pump is intended for private use in house and garden. It must only be operated within the scope of its usage limitations in accordance with the technical data.
The pump is suitable for:
- Water removal in the event of a flood
- Re-pumping and pumping out from vessels (e.g. swimming pools)
- Water removal from streams and shafts
- Water removal from drains and trickle shafts.
- Only applies to the TS 400 ECO pump
The pump is suited exclusively for the conveying of the following fluids:
- Clear water, rainwater
- Water containing chlorine (e.g. swimming pools)
- Waste water
- Dirty water having a max. 5% suspended matter proportion and a grain size of max. 30 mm diameter.
- Only applies to the TS 400 ECO pump
Any use not in accordance with this designated use shall be regarded as misuse.
Possible misuse
The pump must not be used in continuous operation. It is not suitable for conveying:
- Drinking water
- Salt water
- Foodstuffs
- Aggressive media, chemicals
- Corrosive, flammable, explosive or fuming fluids
- Fluids that are hotter than 35 °C
- Water containing sand and abrasive fluids.
- Only applies to the TK 250 ECO pump
SAFETY INSTRUCTIONS
WARNING!
Risk of injury
Defective and disabled safety and protective devices can lead to serious
injury.
-
Have any defective safety and protective devices repaired.
-
Never disable safety and protective devices.
-
Never lift, transport or affix the pump by the connection cable.
-
Unauthorised modifications or conversions to the pump are prohibited.
-
Only use the pump and extension cable if they are in flawless technical condition. Damaged pumps must not be operated.
-
This pump can be used by children of 8 years and older and by persons with reduced physical, sensory or mental capabilities, or those lacking experience and knowledge, if they are supervised or have been instructed with regard to the safe use of the pump and the ensuing risks. Children may not play with the pump.
Cleaning and maintenance must not be carried out by children without supervision. -
People with very strong and complex restrictions may have needs that exceed the instructions described here.
-
Maintain a safe distance to persons or animals or switch off the pump if animals approach.
Electrical safety
DANGER!
Danger from contact with live parts!
A defect in the pump or the extension cable can result in serious injury!
-
Disconnect the connector plug from the mains immediately.
-
Connect the device via an earth leakage circuit breaker with a rated leakage current of < 30 mA.
-
The pump may not be operated while people are in the pool or pond.
-
The mains voltage at your location must comply with the information regarding mains voltage in the Technical Data.
Do not use any other supply voltage. -
The pump must only be operated on electrical equipment in accordance with DIN/VDE 0100, parts 737, 738 and 702.
For fuse protection, a line circuit breaker of 10 A and an earth leakage circuit breaker with a rated leakage current of 10/30 mA must be installed. -
Only use extension leads approved for outdoor use with a minimum cross-section of 1.5 mm2. Always fully unwind cable drums.
-
Damaged or fragile extension cables may not be used.
- Check the condition of you extension cable prior to every use.
INSTALLATION
Mounting the pressure line (1)
- Screw the connecting bracket (6) onto the pump outlet.
- Screw the combination nipple (5) into the connecting bracket.
- Attach the hose to the combination nipple.
NOTE
The combination nipple can be trimmed to suit the selected hose connection.
Use the largest possible hose diameter.
START-UP
Safety
IMPORTANT!
Flood hazard!
In case of pump faults, water can leak out and cause consequential damage due
to flooding.
- By taking suitable measures, ensure that consequential damage caused by flooding is prevented in case of pump malfunctions.
- Operate the pump hanging from a cable or ensure the secure mounting of the pump.
- Operate the pump only if it is fully immersed.
- Make sure there is adequate ground clearance under the pump.
- Never allow the pump to run with a pressure line closed.
- When using in shafts, make sure the size is adequate.
- Always cover the shaft with a secure foot-plate.
OPERATION
Switching the pump on the (2)
IMPORTANT!
Danger of damage to the device
The pump must not draw in any solids. Sand and other abrasive materials in the conveying medium will destroy the pump.
- Ensure that no solids get into the conveying medium.
NOTE
If the pump is placed on muddy, sandy or stony ground, use a suitable plate to
ensure secure mounting.
- Completely uncoil the mains connection cable.
- Make sure that the electrical plug connector is attached in an area safe from flooding.
- Change the terminal position and individually adjust the switching points of the float switch (8).
- Securely clamp the cable of the float switch on the pump housing. The recommended cable length of the float switch is approx. 120mm.
- Slowly immerse the pump into the conveying medium. Hold the pump at a slight angle to allow any trapped air to escape.
- Insert the mains power plug into the power socket.
- The immersion pump switches on automatically using the float switch when a specific water level has been reached, and switches off again if the water drops below the switch-off height.
Switching the pump off
- Remove the mains plug from the plug socket.
Pumping out to residual water level
IMPORTANT!
Danger of damage to the device
When pumping out, there is the danger that the pump will run dry and damage the device.
- Monitor the pump continuously when pumping out to the residual water level and avoid the pump running dry.
- Take the pump out of service when the residual water level is reached by pulling out the mains plug.
The float switch must be operated manually to pump to the residual water level:
- Remove the mains plug from the plug socket.
- Place the float switch upwards and fasten it.
- Insert the mains power plug into the power socket. The pump switches on and starts to feed.
NOTE
If the water drops below the residual water level, the pump will draw air in.
In this case, the pump must be vented when the water level rises and before
using it again.
MAINTENANCE AND CARE
Cleaning the pump
NOTE
After conveying chlorinated swimming pool water or fluids which leave a
residue, the pump must be flushed out with clear water.
- Clean the suction slots on the suction foot with clear water if necessary.
STORAGE
NOTE
If there is the danger of frost, the system must be completely drained and the
pump must be stored in a frost-proof place.
DISPOSAL
Electrical and electronic appliances do not belong in household waste, but should be collected and disposed of separately.
The packaging, device and accessories are made of recyclable materials, and must be disposed of accordingly.
HELP IN CASE OF MALFUNCTION
DANGER!
Danger of electric shock.
When working on the pump, there is the risk of receiving an electric shock.
- Disconnect the mains plug before correcting any malfunctions!
- Faults in the electrical system must be rectified by a qualified electrician.
Malfunction | Possible cause | Remedy |
---|---|---|
Engine does not run. | Impeller blocked | Remove dirt from the suction area. |
Clean with a suitable tool through the opening on the back of the motor
housing.
Thermal protection switch has switched off.| Wait until the thermal protection
switch on the pump switches on again. Take note of the maximum temperature of
the conveying medium. Have the pump inspected.
No mains power.| Check fuses, have the power supply checked by a qualified
electrician.
Float switch does not switch off when the water level rises.| Send the pump to
an AL-KO service facility.
Pump running but does not feed.| Air in pump housing.| Vent the pump by
holding it at an angle.
Blockage on the suction side.| Remove dirt from the suction area.
Pressure line closed off.| Open the pressure lone.
Pressure hose kinked.| Extend the pressure hose.
Delivery rate too low| Hose dia- meter too small.| Use a hose with a bigger
dia- meter.
Blockage on the suction side.| Remove dirt from the suction area.
Feed head to high.| Observe max. feed head, see technical data!
NOTE
In the event of a malfunction which you cannot rectify, please contact our
Customer Service department.
AFTER-SALES / SERVICE
In the event of questions of warranty, repair or spare parts, please contact your nearest ALKO Service Centre.
These can be found on the Internet at: www.al-ko.com/service- contacts
GUARANTEE
We will resolve any material or manufacturing faults on the appliance during the legal warranty period for claims relating to faults, in accordance with our choice either to repair or replace. The legal warranty period is determined by the legislation of the country in which the appliance was purchased.
Our warranty promise applies only if:
- These operating instructions are heeded
- The appliance is handled correctly
- Original spare parts have been used
The warranty becomes void in the case of:
- Unauthorised repair attempts
- Unauthorised technical modifications
- Non-intended use
The guarantee excludes:
- Paint damage that can be attributed to normal wear and tear
- Wear parts that are marked with a frame on the spare parts card
The guarantee period commences with purchase by the first end user. The date
on the proof of purchase is decisive. In the event of a guarantee claim,
please take this guarantee declaration and the original proof of purchase, and
contact your dealer or the nearest authorised customer service centre.
This statement does not affect the purchaser’s statutory claims for defects
against the vendor.
EU DECLARATION OF CONFORMITY
We hereby declare that this product in its marketed form conforms to the requirements of the harmonised EU Directives, EU safety standards and the product-specific standards.
Product
Immersion pump, electrical
Serial number
G3023025
Manufacturer
AL-KO Geräte GmbH
Ichenhauser Str. 14
D-89359 Kötz
Germany
Duly authorised person for technical file
Andreas Hedrich
Ichenhauser Str. 14
D-89359 Kötz Germany
Type
TK 250 ECO
TS 400 ECO
EU directives
2014/30/EU
2014/35/EU
2011/65/EU
2017
Harmonised standards
EN 60335-1:2012
EN 50636-2-41:2012
EN 62233:2008
EN 55014-1:2012
EN 55014-2:2016
EN 61000-3-2:2014
EN 61000-3-3:2014
Kötz, 01/08/2017
Wolfgang Hergeth
Managing Director
AL-KO GERÄTE GmbH | Head Quarter | Ichenhauser Str. 14 | 89359 Kötz |
Deutschland
Telefon: (+49)8221/203-0 | Telefax: (+49)8221/203-8199 | www.al-
ko.com
AL-KO Service: www.al-ko.com/service-contacts
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>