Product Information
Specifications
- Product Name: EasySpiritLevel
- Article Number: 1 609 92A 7GE
- Operating Temperature: 2000 m, 90%
- Storage Temperature: 2B)
- Battery Life: Approximately 20 hours
- Auto Power Off: Approximately 20 minutes
- Weight: 0.46 kg
Product Usage Instructions
Safety Instructions
Ensure the measuring tool is only repaired by qualified personnel using
original spare parts to maintain its safety.
Product Description and Intended Use
The EasySpiritLevel is designed for checking and aligning horizontals and
verticals, suitable for both indoor and outdoor use.
Product Features
- LED tilt indicator (top side)
- Battery compartment cover with locking mechanism
- LED tilt indicator (front side)
- On/off button
- Audio signal button
Battery Information
Ensure correct battery polarity according to the markings inside the
battery compartment. Battery levels are indicated by LED colors.
Maintenance and Service
Refer to the user manual for maintenance and cleaning instructions. Contact
customer service for further assistance or advice.
Disposal
For disposal information, visit www.bosch-
pt.com/serviceaddresses.
Frequently Asked Questions (FAQ)
-
How do I calibrate the EasySpiritLevel?
To calibrate the measuring tool, follow the instructions provided in the user manual under the section ‘Calibration of the Measuring Tool’. -
Can the EasySpiritLevel be used outdoors?
Yes, the EasySpiritLevel is suitable for both indoor and outdoor use. -
What should I do if the battery indicator shows a low level?
If the battery indicator shows a low level, replace the batteries with new ones following the correct polarity as indicated inside the battery compartment.
Safety Instructions
All instructions must be read and observed. The safe guards integrated into the measuring tool may be compromised if the measuring tool is not used in accordance with these instructions. STORE THESE INSTRUCTIONS IN A SAFE PLACE.
- Have the measuring tool serviced only by a qualified specialist using only original replacement parts. This will ensure that the safety of the measuring tool is maintained.
- Do not use the measuring tool in explosive atmospheres which contain flammable liquids, gases or dust. Sparks may be produced inside the measuring tool, which can ignite dust or fumes.
Product Description and Specifications
Please observe the illustrations at the beginning of this operating manual.
Intended Use
The measuring tool is intended for checking and aligning horizontals and
verticals.
The measuring tool is suitable for indoor and outdoor use.
Product Features
The numbering of the product features shown refers to the illustration of the measuring tool on the graphic page.
- LED tilt indicator (top side)
- Battery compartment cover
- Locking mechanism of the battery compartment cover
- LED tilt indicator (front side)
- On/off button
- Audio signal button
Technical Data
Digital level EasySpiritLevel
Article number| 3 603 F67 0…
Measuring range at
0°/90°/180°/270°
| ±3°
Measuring accuracy at 0°/90°/180°/270°A)| ±0.1°
Operating temperature| –10 °C to +50 °C
Storage temperature| –20 °C to +70 °C
Max. altitude| 2000 m
Relative air humidity max.| 90 %
Pollution degree according to
IEC 61010-1
| 2B)
Batteries| 2 × 1.5 V LR6 (AA)
Operating time, approx.| 20 h
Automatic switch-off after approx.| 20 min
Weight according to EPTA-Procedure 01:2014| 0.46 kg
Digital level EasySpiritLevel
Dimensions (length × width × height) 400 × 32 × 64 mm
- The measuring accuracy is ±0.2° for all other measuring ranges.
- Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
Assembly
Inserting/Replacing Batteries
It is recommended that you use alkaline manganese batteries to operate the
measuring tool.
To open the battery compartment cover (2), press the locking mechanism (3) and
fold the battery compartment cover up. Insert the batteries.
When inserting the batteries, ensure that the polarity is correct according to
the illustration on the inside of the battery compartment.
Battery Indicator
The LED tilt indicator (4) flashes after being switched on and indicates the
current battery status for 3 seconds as follows:
Always replace all the batteries at the same time. Only use batteries from the same manufacturer and which have the same capacity.
- Take the batteries out of the measuring tool when you are not using it for a prolonged period of time. The batteries can corrode and self-discharge during prolonged storage in the measuring tool.
Operation
Starting Operation
- Protect the measuring tool from moisture and direct sunlight.
- Do not expose the measuring tool to any extreme temperatures or variations in temperature. For example, do not leave it in a car for extended periods of time. In case of large variations in temperature, allow the measuring tool to adjust to the ambient temperature before putting it into operation. The precision of the measuring tool may be compromised if exposed to extreme temperatures or variations in temperature.
- Keep the supporting surfaces and contact edges of the measuring tool clean. Protect the measuring tool against shock and impact. Dirt particles or deformations can lead to faulty measurements.
- Avoid hard knocks to the measuring tool or dropping it. After strong external influences on the measuring tool, you should always carry out calibration before further work.
Switching On and Off
To switch the measuring tool on or off, press the on/off button (5).
If no button on the measuring tool is pressed or the measuring tool is not
moved for approx. 20 min, the measuring tool will automatically switch itself
off to preserve battery life.
Switching the Audio Signal On and Off
Press the audio signal button (6) to switch the audio signal on or off. When
you switch on the measuring tool, the audio signal is switched off as
standard.
Tilt Indicator
Place the measuring tool on the vertical or horizontal surface being measured.
For each movement of the measuring tool, the measured value is updated. The measured value is displayed visually on the LED tilt indicators on the top side (1) and the front side (4) and acoustically via an audio signal as follows:
The supplied labels contain information about the tilt indicator.
Calibrating the Measuring Tool
Check the accuracy of the measuring tool prior to critical measurements, after
intense variations in temperature as well as after heavy impact.
Perform a measurement to check the accuracy. Turn the measuring tool by 180° around the vertical axis and perform the same measurement again. Compare the two measured values. If the measured values are not identical, calibrate the measuring tool.
Performing the Calibration
The surface onto which you place the measuring tool must not deviate from the
horizontal surface by more than 3°. You can find further information on
calibration on the supplied stickers.
- Switch on the measuring tool .
- Press and hold the audio signal button (6) for 5 seconds. All LEDs on the LED tilt indicator (4) will flash green.
- Place the measuring tool on a horizontal surface.
- Briefly press the audio signal button (6) to start calibration. The LEDs on the LED tilt indicator (4) will flash successively.
- If the first calibration has been completed successfully, all LEDs on the LED tilt indicator (4) will flash green simultaneously and a brief audio signal will sound.
- Turn the measuring tool 180° around the vertical axis: The LED tilt indicator on the top side (1) will still face upwards and the LED tilt indicator on the front side (4) will now be on the side facing away from you.
- Briefly press the audio signal button (6) again. The LEDs on the LED tilt indicator (4) will flash successively again.
- If the second calibration has been completed successfully, all LEDs on the LED tilt indicator (4) will light up green continuously and two brief audio signals will sound. The measuring tool can now be operated.
- Note : If the calibration has failed, the measuring tool returns to measuring mode. The calibration needs to be restarted.
A second calibration can be performed on a vertical surface for verification. To do so, perform the steps listed above on a vertical surface that does not deviate from the vertical plane by more than 3° and turn the measuring tool by 180° around the horizontal axis.
Maintenance and Service
Maintenance and Cleaning
- Keep the measuring tool clean at all times.
- Never immerse the measuring tool in water or other liquids.
- Wipe off any dirt using a damp, soft cloth. Do not use any detergents or solvents.
- When the measuring tool is exposed to rain for an extended period, its function may be impaired. However, after completely drying off, the measuring tool is ready for operation. No calibration is required.
After-Sales Service and Application Service
Our after-sales service responds to your questions concerning maintenance and
repair of your product as well as spare parts. You can find explosion drawings
and information on spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you with any questions
about our products and their accessories.
In all correspondence and spare parts orders, please always include the
10‑digit article number given on the nameplate of the product.
Great Britain
- Robert Bosch Ltd. (B.S.C.)
- P.O. Box 98
- Broadwater Park
- North Orbital Road
- Denham Uxbridge
- UB 9 5HJ
- At www.bosch-pt.co.uk you can order spare parts or arrange the collection of a product in need of servicing or repair.
- Tel. Service: (0344) 7360109
- E-Mail: boschservicecentre@bosch.com
People’s Republic of China
China Mainland
- Bosch Power Tool (China) Co. Ltd.
- Bosch Service Center
- 567, Bin Kang Road
- Bin Kang District
- Hangzhou, Zhejiang Province
- China 310052
- Tel.: (0571) 8887 5566 / 5588
- Fax: (0571) 8887 6688 x 5566# / 5588#
- E-Mail: bsc.hz@cn.bosch.com
- www.bosch-pt.com.cn
- You can find further service addresses at:
- www.bosch-pt.com/serviceaddresses
Disposal
Measuring tools, accessories and packaging should be recycled in an
environmentally friendly manner.
Do not dispose of measuring tools or batteries with household waste.
Only for EU countries
According to the Directive 2012/19/EU on waste electrical and electronic
equipment and its transposition into national law, measuring tools that are no
longer usable, and, according to the Directive 2006/66/EC, defective or
drained batteries must be collected separately and disposed of in an
environmentally correct manner.
If disposed incorrectly, waste electrical and electronic equipment may have
harmful effects on the environment and human health, due to the potential
presence of hazardous substances.
Only for United Kingdom
According to The Waste Electrical and Electronic Equipment Regulations 2013
(SI 2013/3113) (as amended) and the Waste Batteries and Accumulators
Regulations 2009 (SI 2009/890) (as amended), products that are no longer
usable must be collected separately and disposed of in an environmentally
friendly manner.
1 609 92A 7GE | (01.09.2022)
Bosch Power Tools
References
- Invented for life | Bosch Global
- 巧米网为您服务!(QiaoMi.com)
- Bosch Power Tools | Bosch Power Tools
- Location selection | Bosch Power Tools
- 首页
- Service worldwide
- Bosch Elektrowerkzeuge und Zubehör | Bosch Elektrowerkzeuge
- Bosch el-værktøj | Bosch el-værktøj
- Bosch-sähkötyökalut | Bosch-sähkötyökalut
- Outillage électroportatif Bosch | Outillage électroportatif Bosch
- Ηλεκτρικά εργαλεία Bosch | Ηλεκτρικά εργαλεία Bosch
- Invented for life | Bosch Global
- Ana Sayfa | Bosch Türkiye
- herramientasbosch.net
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>