1.1 General
These are the mounting instructions for the Novy unit shown on the cover. The
user manual is delivered separately with this unit. Carefully read these
instructions before installing and commissioning this unit.
This manual makes use of a number of symbols. The meaning of these symbols is
given below.
Symbol | Meaning | Action |
---|---|---|
Read | Carefully read the instructions | |
Warning | This symbol indicates a dangerous situation. |
Follow this instruction to avoid injury and material damage.
1.2 Safety
Observe the following mounting and safety tips for mounting:
- The installation and electrical connection of the unit shall be carried out by an authorized expert. The manufacturer does not accept any responsibility for any damage resulting from faulty building or connection.
- Carefully take the unit from the packaging and check it for damage before mounting. Do not mount the unit in case of any damage.
- Check if all mounting materials have been supplied using the drawings in section 2.2.
- The unit is intended for household use only (preparation of food) excluding any other domestic, commercial or industrial use.
- Position the electrical connection such, that it is located in the cabinet in which the cooking unit is mounted.
- Safety can only be guaranteed if the unit is connected to an earth wire in accordance with the required regulations.
- Do not use an extension cord for connecting to the electricity grid.
- A damaged cooking plate can endanger your safety. Check the cooking plate for visible damage. Do not mount damaged cooking, but contact your supplier.
- Do not modify or change the unit.
- Do not use the cooking plate as a basis or work surface.
- For the users of pacemakers, the magnetic field could influence their operation. We recommend getting information from the retailer or the doctor.
INSTALLATION
Before installation read the general information and safety regulations (see
chapter 1). Mounting shall only be carried out by authorized experts. The user
has to observe the laws and standards of the country of residence.
Installation regulations
The distance between the cooking plate and the wall must be min. 55 mm.
- The cooking plate belongs to protection class « Y ». When built in, there may be a high cabinet side or a wall on one side and at the rear. On the other side, there may be no piece of furniture or unit higher than the cooking surface.
- Min. 650 mm between the work surface and the top cupboard.
- The strips on the wall edges must be heat-resistant.
- Do not mount the unit above a dishwasher, oven, cooling unit or washing machine, or dryer.
- Make sure there is a distance of 20 mm below the casing of the unit for proper ventilation.
- Do not store any flammable and not heat-resistant objects in the drawer below the cooking plate (e.g. sprays).
- There may be absolutely no mechanical tension on the connection cable, such as a drawer.INST
INSTALL THE EXHAUST DUCT (ONLY 1861)
The motor outlet has a rectangular exhaust of 220 x 90 mm. It is recommended
to connect an exhaust duct to this with the same dimensions.
For optimum performance of the hood, it is important to pay attention to the
items mentioned below.
General:
- Make the duct as short as possible and with as few possible bends to the outside.
- Avoid square bends. Use rounded bends for proper air conduction.
- If an exhaust pipe through the outside wall passes a cavity wall, make sure that the exhaust duct fully bridges the cavity and slightly declines to the outside.
- In case of an exhaust pipe through the roof, use a double-walled roof passage with sufficient width.
- Never connect the exhaust to a flue duct.
- Make sure that sufficient air is supplied. Fresh air can be supplied by slightly opening a window or an outside door or by installing an inlet grate.
RECIRCULATION INSTALLATION (ONLY 1861)
With recirculation, a return opening of at least 550 cm² must be provided
in the kitchen furniture in order to blow the cleaned air into the kitchen.
The return opening can be made by making a cut-out in the plinth or by fitting
a grille.
The air outlet can be provided by using the connection adapter. This ensures
the return of the air through a recess in the back wall. The gap between the
back panel and an adjacent piece of furniture or wall must be at least 25 mm.
Another solution is to use the Novy Easy recirculation kit. The return airflow
is then made possible directly in the plinth.
For optimum performance of the hood, it is important to pay attention to the
items mentioned below.
General:
- Make the duct as short as possible and with as few as possible bends.
- Avoid square bends. Use rounded bends for proper air conduction.
Follow the steps below for the assembly of the appliance and use the
installation drawings in these instructions.
1. Take the unit from the packaging in place of the 2 cut-aways in the
packaging to avoid damaging the glass.
2. Check if all materials have been supplied.
3a. Flush mounting
Make a cut-away and a milling edge in the tabletop in accordance with drawing
3a.
3b. Surface mounting
Make a cut-away in the tabletop in accordance with drawing 3b.
3c. Ventilation
Provide a ventilation opening just below the worktop of 4mm over a width of
min. 600mm for sufficient cooling of the induction hob. Also, provide
sufficient air inlet under the appliance.
Remove the grease filter from the extractor in order to prevent damage to the
appliance.
Only 1851
4a. Stick the insulation strip 2 mm from the outer edge at the rear side
of the glass plate.
5a. Install a bend for the exhaust duct. If the exhaust duct is mounted
directly with a downward bend, first place the supplied bend on the unit. The
connection for the exhaust duct is on the rear of the unit. Make the
connection airtight with aluminum tape.
6a. Place the unit in the opening provided. Firmly hold the cooking plate
on the left and right sides. Slightly tilt it and place the rear side into the
openings. Then carefully lower the front side. The duct can now be connected.
For this follow the description in chapter 3.
7a. Disable the main switch of the fuse concerned before connecting the
unit. The unit is supplied with a connection cable. Connect this according to
the available connection (see connection diagram).
BN: Brown
BK: Black
BU: Blue
GY: Grey
GN/YE: Yellow and green
8a. Insert the grease filter frame and the grille into the extraction
opening.
Remove the grease filter from the extractor in order to prevent damage to the
appliance.
Only 1861
The installation and connection to the electrical mains may only be
entrusted to a professional (electrician) who is familiar with the prescribed
standards.
Only 1861
7b1. Push the connection adapter against the back panel of the furniture and
fix it with tape or screws.
7b2. Make the connection with the rest of the ductwork.
8b. Disable the main switch of the fuse concerned before connecting the
unit. The unit is supplied with a connection cable. Connect this according to
the available connection (see connection diagram).
BN: Brown
BK: Black
BU: Blue
GY: Grey
GN/YE: Yellow and green
9b. Replace the Monoblock filter, if removed during installation. Then
insert the grease filter frame and the exhaust air vent into the extraction
opening.
OPTIONAL
Power limitation induction hob
The hob is equipped with a power limitation. If the power level on two zones
exceeds the maximum power, the last selected cooking zone will be maintained,
and the other cooking zone will be automatically reduced. The display of this
zone will flash first, then the level is automatically reduced to the highest
appropriate position. This limitation is set to 7400W from the factory, but
it’s possible to change
Configuration procedure:
- Make sure there is no more pot on the hob
- Disconnect the appliance from the grid by removing the fuse or turning the circuit breaker off.
- Reconnect the table to the grid
- Start the procedure within 2 minutes after reconnecting the hob to the grid
- Make sure all cooking zones are off.
- Do not press on .
-
Press the key and hold it down.
-
Each display shows a .
-
With one finger of the other hand press successively and quickly (in less than 2s) on the . Starting from the front right area and turning counter-clockwise (1 -> 2 -> 3 -> 4) then release the key. A double “beep” indicates an operating error. In this case, repeat the operation from step 1.
-
Select the [ ] key in display “4”.
-
Use the slider to make [ ] appear in display “4”. (This value in display “4” does not mean a power limitation)
-
Select the [ 0 ] key in display “5” and use the slider to enter the desired configuration in the display :
• 0 corresponds to 7400W – 2 fases
• 1 corresponds to 6000W – 2 faces
• 2 corresponds to 5750W – 1 fase
• 3 corresponds to 4600W – 2 fases
• 4 corresponds to 3700W – 1 fase
• 5 corresponds to 3000W – 1 fase
• 6 corresponds to 2750W – 1 fase
• 7 corresponds to 2300W – 1 fase
• 8 corresponds to 1400W – 1 fase -
Press the key to confirm the configuration.
Never place containers on the cooking zones during setup.
WINDOW SWITCH
The unit can also be connected to a window contact switch.
Open the cover of the electronics box.
Connect the input contacts to the control unit.
Novy NV reserves the right at any time and without reservation to change the structure and the prices of its products.
NOVY NV
Noordlaan 6
B – 8520 KUURNE
Tel. 056/36.51.00
Fax 056/35.32.51
E-mail: novy@novy.be
www.novy.com
United Kingdom: +44 (0)207 866 2493
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>