MICRO-LIGHT OPTICS S-1 Ultra Illuminance Spectrophotometer
Appearance Description
button instruction
- Power on : Long press to power on.
- Power off : Long press to power off.
- Measure : Short press to measure.
- Hi berate : Short press to wake up.
HOMEPAGE
After the instrument is started, the logo page appears first, and the home page is displayed after the loading is complete. Each measurement item is arranged on the home page, and the test details page is arranged according to the order of the measurement items on the home page. You can also customize the order of the test items according to your usual testing habits, long-press the icon of the test item and drag it.
Measurement page
After selecting the measurement item, it will jump to the corresponding measurement page, then click the measurement button and the instrument will start to measure. When the drawing bar at the bottom of the page is all blue, ithe measurement is completed, and the test result will be displayed on the interface. You can also scroll left and right to see different measurement items. During the measurement process, you can also press the pause button to end the measurement.
Measurement page
Test data is a scrolling page, you can swipe up and down the scroll bar on the right side of the screen to view the specific test results.
Color quality scale: Fifteen saturated colors are evenly distributed in the visible spectrum to more accurately analyze the light source Color quality.
TLCI
- Rank distribution: Levell:85-100; Level2:75-85; Level 3: 50-75; Level 4: 25-50; Level 5: 0-250
Gamut area index
: TM-30-18 Rf:
: TM-30-18 Rg
The color rendering index shows Ra and Re. Ra indicates the average value of Rl-R8, and Re indicates the average value of Rl-RlS.
CIE coordinates page, you can view CIE-1931, CIE-1960, CIE-1976, three standard coordinate values.On the coordinate chart, you can view the coordinate point position of the corresponding coordinate value.
The two measurement items of color tolerance and color specification can select the corresponding color temperature interval according to the actual color temperature data to view the diagram, or select multiple or all color temperature intervals to view the diagram.
The basic parameters section of the plant lighting measurement project is a scrolling page, you can swipe up and down the scroll bar on the right side of the screen to view the specific test results.
Plant lighting measurement project, in addition to the basic , there is a custom band range for customers to set according to the actual measurement needs. Specific setting path: set options — measurement Settings — wavelength Settings — wavelength range, and then manually enter the band value.
On the stroboscopic page, you can view parameters such as stroboscopic frequency, stroboscopic percentage, SVM, and risk level. In single measurement mode, only the illuminance value is displayed, and the maximum, minimum and average values are not displayed. In continuous measurement mode, the current illumination value is displayed in real time, as well as the maximum, minimum and average value of the current test period.
Compare
Click the “Select Data” button to jump to the page of saved data records. Select two sets of data for comparison. After both sets of data are selected, the interface will display the comparison result. You can swipe left and right to view comparison parameters.
Record
On the Data record page, you can view the saved test data and delete it by selecting one, multiple, or all. After clicking the delete icon on the page, the system will prompt you again whether to delete the data. If you confirm the deletion, click “F”; if you Cancel the deletion, click” x “.
Setting page
You can choose a single measurement mode, click the measurement button once to test a set of data; continuous measurement mode can also be selected click the measurement button to start the continuous measurement, click the pause button to stop the measurement.
By default, the instrument uses automatic integration mode, and the instrument automatically adjusts the integration time according to the intensity of the light source being measured. If you have special measurement needs, you can use manual integration mode.
The wavelength range of photon flux and irradiance can be set according to the actual measurement requirements.
Information Setting
Set the company name, address, telephone, fax, you can also upload the company logo, click “save” after the completion of the setting, these information will be reflected in the generated measurement report.
Start the sleep mode: set the automatic sleep time. After reaching the set
time, if there is no operation the instrument enters the sleep state, press
the measurement button to wake up the instrument.
Turn off sleep mode: When the device is turned on, steady on screen.
Brightness Setting
Drag the circular icon left and right to adjust the brightness of the screen.
Volume setting
You can choose to turn sound effects on or off, or drag the circular icon left
and right to adjust the volume.
Bluetooth Settings
Turn on the Bluetooth of the instrument, search for the mobile phone that
needs to transfer files, and then connect.
Wifi Setting
Turn on the instrument wifi network and connect to a wireless network that can
be used for file transfer.
Three languages are available: Simplified Chinese, Traditional Chinese and English.
Date and time
You can select the corresponding time zone to allow the system to set the time
automatically, or disable the automatic setting and set the current time
manually.
About us
On this page, you can customize the name of the instrument. The name of the
instrument will be displayed synchronously when the Bluetooth connection is
connected to the PC. You can also view the instrument model, software version
number, instrument serial number, and our contact information.
Operating Instructions
Operating button
- Click this button in any interface to return to the main page.
- Click the button on the test page to save the current test data, manually enter the name of the document, and the saved data can be viewed on the data record page.
- Measurement button, in single measurement mode, click to measure one data at a time, in continuous measurement mode, click once to start continuous measurement data.
- Pause button. In continuous measurement mode, click to pause the measurement.
- Select All button to select all saved test data.
- Delete button to delete the currently selected test data.
- Click Data transfer on the test page, you can generate the current test data into a PDF report, and then transfer it via Bluetooth or email. Fill in the detailed information on the transfer preparation page, which will be synchronized to the PDF report. If you choose email transmission, you need to open and connect to the wifi first, and then enter the correct email address; If you choose Bluetooth transmission, you need to turn on and connect the Bluetooth device first, and then transfer.
Test report
PC Software
The instrument is equipped with PC software, the instrument is connected to the computer through the TypeC data cable, the instrument can be controlled by the PC software for measurement, the data saved in the instrument can also be imported to the PC software for viewing, and the test report can be generated.
FCC
FCC Caution.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference t hat may cause undesired operation.Any Changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.Note: This equipment
has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more o f the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment an nd receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
*RF warning for Portable device: The device has been evaluated to meet general RF exposure requirements.The device can be us importable exposure condition without restriction.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>