Viproud FC-IR209 Infrared Thermometer User Manual
- June 1, 2024
- Viproud
Table of Contents
- Viproud FC-IR209 Infrared Thermometer
- Introduction
- Warnings and Precautions
- Product Description
- Features
- Product Structure
- How to Use Your Thermometer
- Temperature Taking Tips
- Care and Cleaning
- Error and Troubleshooting
- Specif ications
- EMC Information
- Warranty and After-Sale Service
- FREQUENTLY ASKED QUESTIONS
- VIDEO – PRODUCT OVERVIEW
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Viproud FC-IR209 Infrared Thermometer
Customer Service
Email Us
- Customer Support: support@viproud.net
Introduction
Thank you for purchasing this Non-contact forehead Infrared Thermometer. It is carefully developed for accurate, safe and fast temperature measurements in the forehead. Please read these instruct ions carefully before using this product and keep the Instructions and the thermometer in a safe place.
Package Contents
No. | Name | Quantity |
---|---|---|
1 | Infrared Thermometer | 1 |
2 | Battery (AAA, optional) | 2 |
3 | User Manual | 1 |
4 | Pouch | 1 |
Warnings and Precautions
- Never immerse the thermometer in water or other liquids (not waterproof). For cleaning and disinfecting ing please follow the instruct ions in the “Care and Cleaning” section.
- Never use the thermometer for purposes other than those it has been intended for. Please follow the general safety precaut ions when using on children.
- Keep the thermometer away from direct exposure to the sun and keep it in a dust-free, dry area, well-ventilated place at a temperature between 50°F(10°C) – 104°F(40°C). Do not use the thermometer in high-humidity environments. (>95%RH)
- Do not use the thermometer if there are signs of damage on the measuring sensor or on the instrument itself. If damaged, do not attempt to repair the instrument! Please contact the dealer.
- This thermometer consists of high-quality precision parts. Do not drop the instrument. Protect it from severe impact and shock. Do not twist the instrument or the measuring sensor.
- Please consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration, changes in appet ite or activity seizure, muscle pain, shivering, st if f neck, pain when urinat ing, etc., even in the absence of fever.
- Even in the absence of a fever, those who exhibit a normal temperature may still need to receive medical attention. People who are on antibiotics, analgesics, or antipyretics should not be assessed solely on temperature readings to determine the severity of their illness.
- This thermometer is not intended for pre-term babies or small-for gestational-age babies. This thermometer is not intended to interpret hypothermic temperatures, Do not allow children to take their temperatures unattended.
- Use of this thermometer is not intended as a substitute for consultation with your physician or pediatrician. It is for household use only.
- Clean the thermometer probe after each use.
- Do not use the thermometer on newborns or for continuous temperature monitoring purposes.
- Keep out of reach of children under 12 years. Children under 12 years old must operate with an adult.
- Do not take a measurement while or immediately after nursing a baby.
- Patients should not drink, eat, or be physically active before/while taking the measurement.
- Temperature elevation may signal a serious illness, especially in adults who are old, frail, have a weakened immune system, or neonates and infants. Please seek professional advice immediately when there is a temperature elevation and if you are taking temperature for whom are:
- Over 60 years of age (Fever may be blunted or even absent in elderly patients)
- Having diabetes mellitus or a weakened immune system (e.g.,HIV positive, cancer, chemotherapy, chronic steroid treatment splenectomy)
- Bedridden (e.g., nursing home patient, stroke, chronic illness)
- A transplant patient (e.g., liver, heart, lung, kidney)
Product Description
Overview
- Infrared Thermometer measures the body temperature based on the infrared energy emit ted from the forehead. Users can quickly get measurement results af ter properly scanning the forehead.
- Normal body temperature is a range. The following tables show that this normal range also varies by site. Therefore, readings from dif ferent site should not be directly compared. Tell your doctor what type of thermometer you used to take your temperature and on which part of the body.
- Also, bear this in mind if you are diagnosing yourself.
Measuring Part| Measurements
---|---
Forehead temperature| 97.0°F to 99.5°F (36.1°C to 37.5°C)
Ear temperature| 96.4°F to 100.4°F (35.8°C to 38.0°C)
Oral temperature| 95.9°F to 99.5°F (35.5°C to 37.5°C)
Rectal temperature| 97.9°F to 100.4°F (36.6°C to 38.0°C)
Axillary temperature| 94.5°F to 99.1°F (34.7°C to 37.3°C) - Structure The thermometer consists of a casing, an LED screen, a measure button, a beeper, an infrared temperature sensor, and a microprocessor.
- Operating Principle The infrared temperature sensor collects infrared energy emitted by the skin surface. After being focused by a lens, the energy is converted into a temperature reading by the thermopiles and measurement circuits.
- Indications for Use The Non-contact Infrared Thermometer is intended for the measurement of human body temperatures. The forehead mode is indicated for people of all ages.
Features
- Non-Contact Design, Safe and more hygienic to use
- Quick measurement, less than 1 second
- Accurate and reliable
- Easy operation, one button design
- Multi-functional: can measure temperature of forehead, room, milk, water and object
- 35 sets of memories, easy to recall
- Switching between mute and un-mute mode
- Fever alarm function, displayed in orange and red light
- Switching between °F and °C
- Auto shut-down and power-saving
Product Structure
- LED Screen
- Measure Button
- Memory Button (or Forehead/Object Conversion)
- Mute/Un-mute Button (or °F/°C Conversion)
- Sensor
- Indicator Light
- Rating Label
- Battery Cover
Display Description
- Temperature value
- Forehead temperature mode
- Object temperature mode
- Mute / Un-mute
- Celsius degrees
- Fahrenheit degrees
- Battery level
- Memory recall
How to Use Your Thermometer
When using the thermometer for the first t ime, please install the batteries.
Press the Measure Button to Turn On the Thermometer
Hold the thermometer within 0-1.5 inches of the forehead and aim it at the center, start measuring with a short press of “Measure” but ton, then you can read the value.
Remarks: please measure forehead temperature in forehead temperature mode (the screen will show ” “)
- If the eyebrow area is covered with hair, sweat or dirt, please clean the area beforehand to improve the reading accuracy.
- Always check if the lens is clean.
- Always make sure the user and the thermometer will have been in the same room prior to the measurement.
2 Take Room/Object Temperature
- When the thermometer is powered off, long press the “ ” button for 3 seconds until it shows . Then press the ” ” button to measure.
- Keep the thermometer about 1-1.5 inches (1-3 cm) away from the object.
- Press and release the ” ” button in 1 second, you can read the value after hearing the beep.
- Turn off the thermometer, and restart it, then get back to forehead mode.
After a Measurement
Once the reading has been completed, remove the thermometer away from the forehead and observe temperature. After each measurement, you can enter the recall mode and query earlier temperature readings.
- Do not hold the thermometer for a long time, because it is sensitiveto the ambient temperature.
- After each measurement, clean the temperature probe with a soft cloth, and put the thermometer in a dry and well-ventilated place.
- You should wait at least 10 seconds between each measurement.
- It is dangerous to make a self-diagnosis or self-treatment based on the obtained measurement results. For such purposes, please consult a doctor.
Read Your Temperature
“T” indicates a temperature reading.
In Forehead Mode:
- If 89.6°F ≤ T ≤ 99.2°F (32°C ≤ T ≤ 37.3°C), the green light will be around the button last for 3 seconds, with one long beep.
- If 99.3°F ≤ T ≤ 100.3°F (37.4°C ≤ T ≤ 37.9°C), the orange light will be around the button last for 3 seconds, with 3 short beeps, and the value in LED screen flickers, which is a warning that you may have a light fever.
- If 100.4°F ≤ T ≤ 109.2 °F (38°C ≤ T ≤ 42.9°C), the red light will be around the button last for 3 seconds, with 5 short beeps, and the value in LED screen flickers, which is a warning that you may have a high fever.
Switching Between Mute and Un-mute
- When the thermometer is turned on, short press the ” ” button in 1s to switch from un-mute to mute.
- The mute/unmute function is switchable both in the forehead mode and the object/room temperature mode.
- Un-mute is only beep sound, not broadcast temperature.
Checking 35 Sets of Memory Data
- When the thermometer is turned on by short press the “ ” button in 1s to enter the memory mode, press this button again to check the 35 sets of memories one by one. If it shows no value it will display ” – – – “
- The memory data will be lost when removing the batteries.
°F/°C Conversion
- When the thermometer is turned on, keep long pressing the “ ” button for 3 seconds, to change the °F/°C.
Temperature Compensation Adjustment
- When the thermometer is turn on, press both the “ ” button and “ ” button for 2-3 seconds to enter the temperature compensation mode.
- By pressing the “ ” to adjust the temperature from 0.0°F(°C) to #2.0°F(°C).
NOTE: All the future temperature you are taking will be automatically added to the value you adjusted.
To Turn Off
- The unit will shut down automatically after 12+1 seconds without using.
- Keep pressing the “ ” button for 6 seconds, it will shut down.
Caution
- All memory records will loss when the battery is removed or reinstalled.
- All settings will come to default when removing the battery. If the settings need to be adjusted, please power on and make the new settings.
Replace the Battery
- Slide the battery cover off along the marked direction. Put two AAA batteries correctly into the compartment.
- Remove the batteries if the thermometer will not be used for more than two months.
Reset the Thermometer
- When the screen shows “—“, “Hi” or any other accuracy issues that can’t be solved, please remove the battery and reset the thermometer.
Disposal: For environmental reasons, do not dispose of the device in the household waste at the end of its useful life. Dispose of the unit at a suitable local collection or recycling point.
Observe the local regulations for material disposal.
- Please dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.
- Batteries must not be disposed of with household waste. As a consumer, you are required by law to recycle used batteries. You can recycle your old batteries at public collection points in your community or wherever batteries of the relevant type are sold.
- The codes below are printed on batteries containing harmful substances:
- Pb = Battery contains lead,
- d = Battery contains cadmium,
- Hg = Battery contains mercury.
The batteries in this device do not contain any pollutants.
Temperature Taking Tips
- It is important to know each individual’s normal temperature when they are well. This is the only way to accurately diagnose a fever. Record readings twice a day (early morning and late afternoon). Take the average of the two temperatures to calculate normal oral equivalent temperature. Always take the temperature in the same location, since the temperature readings may vary from different locations on the forehead.
- A child’s normal temperature can be as high as 99.9°F (37.7°C) or as low as 97.0°F (36.11°C). Please note that this unit reads 0.9°F (0.5°C) lower than a rectal digital thermometer.
- Holding the thermometer for too long in the hand before taking a measurement can cause the device to warm up. This means the measurement could be incorrect.
- Patients and the thermometer should stay in steady-state room condition. Before placing the thermometer sensor onto the forehead, remove dirt, hair, or sweat from the forehead area. Wait 10 minutes after cleaning before taking measurement.
- Use an alcohol swab to carefully clean the sensor and wait for 5 minutes before taking a measurement on another patient. Wiping the forehead with a warm or cool cloth may impact your reading. It is advised to wait 10 minutes before taking a reading.
- In the following situations, it is recommended that 3-5 temperatures in the same location be taken and the highest one taken as the reading:
- Newborn infants in the first 100 days.
- Children under three years of age with a compromised immune system and for whom the presence or absence of fever is critical.
- When the user is learning how to use the thermometer for the first time until he/she has familiarized himself/herself with the instrument and obtains consistent readings.
Care and Cleaning
- Cleaning and user maintenance must not be performed by children unless supervised.
- Cleaning the device use an alcohol swab or cotton swab moistened with 95% alcohol to clean the thermometer casing and the measuring probe.
- After the alcohol is completely dried out, you can take a new measurement (minimum of 10 minutes).
- Ensure that no water is left in the device. If this happens, only use the device again once it is fully dried out.
- Never use abrasive cleaning agents, thinners or benzene for cleaning and never immerse the instrument in water or other cleaning liquids.
- Be careful not to scratch the surface of the LED screen.
- Remove the batteries from the device before cleaning.
- Clean the device after use with a soft, slightly damp cloth. If they are very dirty, you can also moisten the cloth with a mild soapy solution.
Error and Troubleshooting
Symptom | Possible Cause | Description & Solution |
---|
Failed to power on
| The battery level is too low.| Replace with a new battery.
Polarities of the batteries are
reversed.
| Ensure the batteries are in the
right position.
The thermometer is
damaged.
| Contact dealer.
Symptom| Possible Cause| Description & Solution
---|---|---
The reading is too low
| The lens of the probe is dirty.| Clean the lens with a cotton swab.
The distance of the item
and the target is too far.
| Ensure the thermometer measuring
the forehead center within 1.5 inches.
You have just come from a cold environment.| Stay in a warmer room before
taking a reading.
The reading is too high| You have just come from a hot environment.| Stay in
an adequately cool room before taking a reading.
| The ambient temperature is not in the range.| 3 short beeps and red
indicator light for 3 seconds. Take a measurement under an ambient temperature
bet- ween 50.0°F (10°C) and 104°F (40°C).
|
Memory Error.
| 3 short beeps and red indicator light for 3 seconds. Contact dealer.
|
In forehead mode,
T > 109.2°F (42.9°C).
| 3 short beeps and red indicator light for 3 seconds. The measured object is
not correct, please measure the body temperature in forehead mode.
| 2.5V ± 3% ≤ power voltage ≤ 2.6V ± 3%.| The battery level is low,it suggests
you replace the battery, but you can continue to use it.
| The power voltage is
lower than 2.5V ± 3%.
| It will turn off automatically after 30 seconds. Please replace with a new battery.
| 3 short beeps and red indicator light for 3 seconds. “—” means the measurement failure.
The possible cause is as follow:
· The measurement distance is more than 1.5 inches (3 cm).
· The measured temperature is lower than 89.6°F (32°C).
* Do not use the forehead mode to measure room/object temperature,and must wait until the beep stops completely before checking the temperature value.
- If not solved, please contact the dealer.
Specif ications
Product Name | Infrared Thermometer |
---|---|
Power supply | DC1.5Vx2 |
Measurement range | Forehead: 89.6°F-109.2°F (32.0°C-42.9°C) |
Object: 32°F-212°F (0°C-100°C)
Accuracy (Laboratory)| Forehead mode| ±0.4°F/±0.2°C
Object mode| ±1.8°F/±1.0°C
Display resolution| 0.1°F/°C
Measuring distance| 0-1.5 inches (0-3 cm)
Automatic shutdown| 10s±1s
Memory| 35 groups of measured temperature
Battery| 2*AAA
Weight & Dimension| 74g (without battery), 35.5×148.6x42mm
Operating conditions
| OperatingTemperature: 50°F~104°F (10°C~40°C) Relative Humidity: ≤ 85% moisture condensation
Atmospheric pressure: 70-106kPa
Storage conditions| StorageTemperature: -4°F~131°F (-20°C~55°C) Relative
Humidity: ≤ 95% moisture condensation
Device Life| 5 Years
Symbols
SN | Serial number |
---|---|
LOT | Batch number |
IMPORTANT |
Inaccurate reading or thermometer damage may occur if the thermometer is not correctly used.
IP22| 2 Protected against solid foreign objects of 12,5mmØ and greater;
2 If keep the thermometer in 15 degree angle, it still can prevent the water drop.
EMC Information
IEC 60601-1-2: 2014 ME EQUIPMENT and ME SYSTEMS ident if icat ion, marking and documents for Class B product. The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments and so on.
-
Warning: Don’t near act ive HF surgical equipment and the RF shielded room of an ME system for magnet ic resonance imaging, where the intensity of EM disturbances is high.
-
Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper
operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operat ing normally. -
Warning: Use of accessories, transducers and cables other than those specif ied or provided by the manufacturer of this equipment could result in increased electromagnet ic emissions or decreased electromagnet ic immunity of this equipment and result in improper operat ion.
-
Warning: Portable RF communicat ions equipment (including peripherals such as antenna cables and external antennas)should be used no closer than 12 inches (30cm) to any part of the Infrared Thermometer (FC-IR209), including cables specif ied by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
-
If any: A list of all cables and maximum lengths of cables (if applicable), transducers and other ACCESSORIES that are replaceable by the RESPONSIBLE ORGANIZATION and that are likely to af fect compliance of the ME EQUIPMENT or ME SYSTEM with the requirements of Clause 7
(EMISSIONS) and Clause 8 (IMMUNITY). -
ACCESSORIES may be specif ied either generically (e.g. shielded cable, load impedance) or specif ically (e.g. by MANUFACTURER and EQUIPMENT OR TYPE REFERENCE).
-
If any: The performance of the ME EQUIPMENT or ME SYSTEM that was determined to be ESSENTIAL PERFORMANCE and a description of what the OPERATOR can expect if the ESSENTIAL PERFORMANCE is lost or degraded due to EM DISTURBANCES (the defined term “ESSENTIAL PERFORMANCE” need not be used).
Technical Description:
- All necessary instructions for maintaining BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to electromagnetic disturbances for the excepted service life.
- Guidance and manufacturer’s declaration-electromagnetic emissions and Immunity.
Table 1
Guidance and Manufacturer’s Declaration-electromagnetic Emissions
Emissions test| Compliance
RF emissions CISPR 11| Group 1
RF emissions CISPR 11| Class B
Harmonic emissions IEC 61000-3-2| N/A
Voltage fluctuations/flicker emissions IEC61000-3-3| N/A
Table 2
Guidance and Manufacturer’s Declaration – electromagnetic Immunity
Immunity Test| IEC60601-1-2 Test Level| Compliance
Level
Electrostatic discharge (ESD) IEC 61000-4-2| ±8kV contact ±2KV, ±4kV,
±8kV, ±15kV air
| ±8 kV contact ±2 kV,
±4 KV, ±8kV,±15kV air
Electrical fast transient
/burst IEC 61000-4-4
| Power supply lines: ±2 KV input/output lines: ±1 kV 100kHz repetition frequency|
N/A
Surge IEC 61000-4-5| line (s) to line (s): ±1 KV
line (s) to earth: ±2 KV
| N/A
Voltage dips, short interruptions and voltage variations on power supply input
lines IEC 61000-4-11
| 0% 0.5 cycle At 0°, 45°, 90°, 135°,
180°, 225°, 270° and 315° 0%
1 cycle And 70% 25/30 cycles
Single phase: at 0 0% 250 cycle
|
N/A
Power frequency magnetic field IEC 61000-4-8| 30A/m
50Hz/60Hz
| 30A/m
50Hz/60Hz
Conduced RF IEC 61000-4-6| 150KHz to 80MHz: 3Vms 6Vrms (in ISM and amateur radio bands) 80% Am at 1kHz|
N/A
Radiated RF
IEC 61000-4-3
| 10V/m, 80MHz-2,7GHz
80% AM at 1 kHz
| 10V/m , 80MHz-2,7GHz
80% AM at 1 kHz
NOTE UT is the a.c. mains voltage prior to application of the test level.
Table 3
Guidance and Manufacturer’s Declaration – electromagnetic Immunity
Radiated RF IEC 61000-4-3
(Test specificat
-ions for ENCLOSURE PORT IMMUNITY to
RF wireless communicat- ions
equipment)
| Test Frequency (MHZ)| Band (MHZ)|
Service
| Modula- tion| Modula- tion (W)| Distance (m)| IMMUNITY TEST LEVEL
(V/m)
385| 380-390| TETRA 400| Pulse modulation 18Hz|
1.8
|
0.3
|
27
450
|
430-470
| GMRS 460,
FRS 460
| FM ±5kHz
deviation
1 kHz sine
|
2
|
0.3
|
28
710|
704-787
| LTEBand 13
, 17
| Pulse modulation 217Hz|
0.2
|
0.3
|
9
745
780
Radiated RF IEC 61000-4-3| 810|
800-960
| GSM800/900, TETRA800, iDEN 820, CDMA850,
LTE Band 5
| Pulse modulation 18 Hz|
0.2
|
0.3
|
28
|
---|---|---|---|---|---|---|---|---
870|
930|
(Test specificat| 1720| | GSM 1800; GSM 1900;| Pulse modulation 217 Hz| | |
|
-ions for| 1700-1990| GSM 1900; DECT; LTE| 2| 0.3| 28|
1845|
ENCLOSURE
PORT IMMUNITY to
RF wireless communicat- ions equipment)
| | Band 1,3,4,25; UMTS| | | |
1970|
2450
|
2400-2570
| Bluetooth, WLAN, 802.11
b/g/n, RFID 2450,
LTE Band 7
| Pulse modulation 217 Hz|
2
|
0.3
|
28
|
5240|
5100-5800
| WLAN 802.11
a/n
| Pulse modulation 217 Hz| 0.2| 0.3| 9|
5500|
5785|
Warranty and After-Sale Service
- The device is under warranty for lifetime unlimited from the date of purchase.
- The bat teries, the packaging, and any damage caused by improper use are not covered by the warranty.
- Excluding the following user-caused failures:
- Failure result ing from unauthorized disassembly and modif icat ion.
- Failure result ing from an unexpected dropping during application or transportat ion.
- Failure result ing from not following the instruct ions in the operating manual.
INFRARED THERMOMETER
- After-Sale Service: support@viproud.net
- U.S. Agent: CTI U.S. Inc. Suite 230,1455 Cti U.S. Inc. Lincoln Parkway, Atlanta, Ga, 30346
- RIOMAVIX S.L. Calle de Almansa 55, 1D, Madrid, 28039 Spain SRN: ES-AR-000001202
FREQUENTLY ASKED QUESTIONS
How does the Viproud FC-IR209 Infrared Thermometer measure temperature?
The Viproud FC-IR209 Infrared Thermometer uses infrared technology to detect surface temperatures without direct contact.
Is the Viproud FC-IR209 Infrared Thermometer suitable for both personal and professional use?
Yes, the Viproud FC-IR209 Infrared Thermometer is suitable for home use and professionals in healthcare and industrial settings.
How accurate is the Viproud FC-IR209 Infrared Thermometer?
The Viproud FC-IR209 Infrared Thermometer provides accurate readings within a small margin of error, ensuring reliable temperature measurement.
What temperature range does the Viproud FC-IR209 Infrared Thermometer cover?
The Viproud FC-IR209 Infrared Thermometer measures temperatures within a wide range, often between -50°C to 380°C (-58°F to 716°F).
How quickly does the Viproud FC-IR209 Infrared Thermometer provide readings?
The Viproud FC-IR209 Infrared Thermometer delivers temperature readings within seconds, ensuring efficient measurements.
Can the Viproud FC-IR209 Infrared Thermometer be used for measuring body temperature?
The Viproud FC-IR209 Infrared Thermometer is designed primarily for surface temperatures and may not be optimized for body temperature readings.
Does the Viproud FC-IR209 Infrared Thermometer have an automatic shutoff feature?
Yes, the Viproud FC-IR209 Infrared Thermometer typically includes an auto- shutoff feature to preserve battery life.
Can the Viproud FC-IR209 Infrared Thermometer toggle between Celsius and Fahrenheit?
Yes, the Viproud FC-IR209 Infrared Thermometer allows users to easily switch between Celsius and Fahrenheit units.
What type of battery does the Viproud FC-IR209 Infrared Thermometer use?
The Viproud FC-IR209 Infrared Thermometer is powered by standard AAA batteries for convenient replacement.
How do I know if the Viproud FC-IR209 Infrared Thermometer is low on battery?
The Viproud FC-IR209 Infrared Thermometer usually has a low battery indicator displayed on the screen.
Can the Viproud FC-IR209 Infrared Thermometer measure liquid temperatures?
Wipe down the Viproud FC-IR209 Infrared Thermometer's exterior with a clean, dry cloth to avoid damaging the sensor.
Does the Viproud FC-IR209 Infrared Thermometer have a memory feature?
Some models of the Viproud FC-IR209 Infrared Thermometer may offer basic memory functions for the last recorded temperature.
How do I change the temperature units on the Viproud FC-IR209 Infrared Thermometer?
The Viproud FC-IR209 Infrared Thermometer is designed to withstand regular use but should be handled carefully to avoid damaging the sensor.
Can I rely on the Viproud FC-IR209 Infrared Thermometer for industrial use?
Yes, the Viproud FC-IR209 Infrared Thermometer can handle a wide range of temperatures, making it suitable for industrial applications.
What is the warranty period for the Viproud FC-IR209 Infrared Thermometer?
The Viproud FC-IR209 Infrared Thermometer typically comes with a standard one- year warranty.
VIDEO – PRODUCT OVERVIEW
DOWNLOAD THE PDF LINK:Viproud FC-IR209 Infrared Thermometer User Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>