Everest Jennings 90763550 Advantage LX and Advantage Recliner Wheel Kit Installation Guide
- June 1, 2024
- Everest Jennings
Table of Contents
Everest Jennings 90763550 Advantage LX and Advantage Recliner Wheel Kit Installation Guide
⚠ WARNING: Important! Read and understand these instructions before
installing the wheel kit. If the wheel kit is not properly installed, personal
injury and damage to the wheel and/or wheelchair could result.
⚠ WARNING: If components are damaged or missing, contact your GF Health
Products, Inc. (“GF”) authorized distributor immediately. DO NOT use
substitute parts. Use only Everest & Jennings (“E&J”) replacement parts.
Non-E&J replacement parts could cause personal injury and cause damage to the
wheel or wheelchair.
⚠ WARNING: GF Health Products, Inc. assumes no responsibility for any damage
or injury caused by improper assembly, installation or use of this product.
INTENDED USE
This product is intended as wheel replacement only.
⚠ WARNING: Make note of the placement of the wheel on the wheelchair frame, some frames have multiple threaded height positions. Always replace wheel kits in the same location to ensure proper fit of wheel locks and that wheelchair arms do not come in contact with the wheels.
INSTALLATION
REMOVAL OF OLD WHEEL (SEE PICTURES 1-2 BELOW)
Fold wheelchair to reduce the movement/play. Lay the wheelchair on the
opposite side of the wheel to be replaced, ensure wheel lock is engaged on the
wheel on bottom side to ensure chair doesn’t move or rotate. Remove cap cover
on wheel center top to expose the bolt. Using a 3/4″ socket and/or wrenches on
both the bolt and the nut on inside of wheelchair frame, loosen and then
remove the nut from the bolt threads. Once the nut has been removed, slowly
pull the bolt out from the frame of the chair. Keep the bolt and nut, you will
reuse them for the new wheel assembly.
INSTALLATION OF NEW WHEEL (SEE PICTURE 3 BELOW)
Refer to picture 3 to ensure proper placement of the bolt, wheel and nut. Once
the wheel kit has been assembled, slowly lower the bolt through the hole in
the side frame of the wheelchair. When the bolt has been pushed through the
frame, screw the nut onto the threaded part of the bolt on the inside of the
frame. Using a 3/4″ socket and/or wrench on both the bolt head and nut,
tighten them as much as possible while still allowing the wheel to rotate.
Ensure the wheel rotates and doesn’t have any pull or gap/wobble before
placing it back upright on all 4 wheels. Place the cap cover back on the wheel
and tap slightly with a rubber mallet to secure it to the wheel.
⚠ WARNING: Always check both wheels before sitting in the chair to ensure
both the bolt and nut are completely tight, no gaps or wobble should be
present and the wheels should rotate easily without pulling or rubbing.
⚠ WARNING: Check the wheel locks before operating the wheelchair under
normal use to ensure proper alignment and ability to hold the wheelchair in
place.
WARRANTY
SCOPE OF WARRANTY
GF Health Products, Inc. (“GF”) warrants to the original purchaser only that
it will replace or repair components, at GF’s sole discretion, that are
defective in material or workmanship under normal use and service. All
warranties are conditioned upon the proper use of the products strictly in
accordance with good commercial practice and applicable GF instructions and
manuals, including proper use and maintenance. To the extent that a third
party warrants a component, GF conveys all of its rights under that warranty
to the original purchaser, to the extent permitted.
This limited warranty shall only apply to defects that are reported in
accordance with the provisions set forth in this warranty document, within the
applicable warranty period and which, upon examination by GF or its authorized
representative, prove to be a warranty item. (See Obtaining Warranty Service
below) This limited warranty is not transferable. The warranted components and
time periods are set forth below:
Wheel Kit:…………………………………………….three (3) months
Labor is not included in the warranty. The warranty period is as designated
above. If a part is replaced under warranty, the original warranty period will
not be affected. All other replacement parts will be subject to the warranty
period specified. The applicable warranty period shall commence from date of
shipment to the original customer, unless there is an expiration date on the
component in which case the warranty shall expire on the earlier of warranty
period or the expiration date. *Please see USER MANUAL for detailed Warranty
Information or contact your GF representative at
1-770-368-4700.
Manufactured For:
GF Health Products, Inc. One Graham-Field Way, Atlanta, GA 30340 Made In China
© 2024, GF Health Products, Inc. All Rights Reserved. Everest & Jennings is a
registered trademark of GF Health Products, Inc.
EJ_GF2400052_ADV-INS-LAB-RevA24
Instagram
Linkedin
YouTube
Facebook
+1 770.368.4700
Information contained herein is subject to change without notice. The most
current and complete product information can be found on our website.