Everest and Jennings 90762922 Paramount Xd Wheel Kit Instructions

September 29, 2024
Everest and Jennings

90762922 Paramount Xd Wheel Kit

90762922: PARAMOUNT XD WHEEL KIT
INSTALLATION AND OPERATION INSTRUCTIONS

SAVE THESE INSTRUCTIONS FOR FUTURE USE

WARNING: Important! Read and understand these instructions before installing the wheel kit. If the  wheel kit is not properly installed, personal injury and damage to the wheel and/or wheelchair could  result.

WARNING: If components are damaged or missing, contact your GF Health Products, Inc. (“GF”)  authorized distributor immediately. DO NOT use substitute parts. Use only Everest & Jennings (“E&J”)  replacement parts. Non-E&J replacement parts could cause personal injury and cause damage to the wheel or wheelchair.

 WARNING: GF Health Products, Inc. assumes no responsibility for any damage or injury caused by  improper assembly, installation or use of this product.

INTENDED USE

This product is intended as wheel replacement only.

WARNING: Make note of the placement of the wheel on the wheelchair frame, some frames have  multiple threaded height positions. Always replace wheel kits in the same location to ensure proper fi t of  wheel locks and that wheelchair arms do not come in contact with the wheels.

INSTALLATION REMOVAL OF OLD WHEEL (SEE PICTURES 1-2 BELOW)

Fold wheelchair to reduce the movement/play. Lay the wheelchair on the opposite side of the wheel to be  replaced, ensure wheel lock is engaged on the wheel on bottom side to ensure chair doesn’t move or rotate.  Remove cap cover on wheel center top to expose the bolt. Using a 3/4″ socket and/or wrench on the bolt and  a 7/8″ socket and/or wrench on the nut on inside of wheelchair frame, loosen and then remove the nut and  spacer from the bolt threads. Once the nut and spacer has been removed, slowly pull the bolt out from the  frame of the chair. Keep the bolt, nut, and spacer, you will re-use them for the new wheel assembly.

EJ_GF2400082_XD-INS-LAB-RevA24 www.grahamfield.com

INSTALLATION OF NEW WHEEL (SEE PICTURE 3 BELOW)

Refer to picture 3 to ensure proper placement of the bolt, wheel, nut, and spacer. Once the wheel kit has been  assembled, slowly lower the bolt through the hole in the side frame of the wheelchair. When the bolt has been  pushed through the frame, insert the spacer, then screw the nut onto the threaded part of the bolt on the inside  of the frame. Using a 3/4″ socket and/or wrench on the bolt head and use a 7/8″ socket and/or wrench on  the nut, tighten nut as much as possible while still allowing the wheel to rotate. Ensure the wheel rotates and  doesn’t have any pull or gap/wobble before placing it back upright on all 4 wheels. Place the cap cover back on  the wheel and tap slightly with a rubber mallet to secure it to the wheel.

WARNING: Always check both wheels before sitting in the chair to ensure both the bolt and nut are  completely tight, no gaps or wobble should be present and the wheels should rotate easily without  pulling or rubbing.

WARNING: Check the wheel locks before operating the wheelchair under normal use to ensure proper  alignment and ability to hold the wheelchair in place.

WARRANTY

SCOPE OF WARRANTY

GF Health Products, Inc. (“GF”) warrants to the original purchaser only that it will replace or repair components, at  GF’s sole discretion, that are defective in material or workmanship under normal use and service. All warranties  are conditioned upon the proper use of the products strictly in accordance with good commercial practice and  applicable GF instructions and manuals, including proper use and maintenance. To the extent that a third party  warrants a component, GF conveys all of its rights under that warranty to the original purchaser, to the extent  permitted.

This limited warranty shall only apply to defects that are reported in accordance with the provisions set forth in this  warranty document, within the applicable warranty period and which, upon examination by GF or its authorized  representative, prove to be a warranty item. (See Obtaining Warranty Service below) This limited warranty is not  transferable.

The warranted components and time periods are set forth below:

Wheel Kit:…………………………………………….three (3) months

Labor is not included in the warranty.

The warranty period is as designated above. If a part is replaced under warranty, the original warranty period will not  be affected. All other replacement parts will be subject to the warranty period specified. The applicable warranty  period shall commence from date of shipment to the original customer, unless there is an expiration date on the  component in which case the warranty shall expire on the earlier of warranty period or the expiration date. *Please see USER MANUAL for detailed Warranty Information or contact your GF representative at 1-770-368-4700.

Manufactured For:
GF Health Products, Inc.
One Graham-Field Way, Atlanta, GA 30340
Made In China
© 2024, GF Health Products, Inc. All Rights Reserved.  Everest & Jennings is a registered trademark of  GF Health Products, Inc.
+1 770.368.4700
Information contained herein is subject to change without notice.  The most current and complete product information can be found on our website.

EJ_GF2400082_XD-INS-LAB-RevA24 www.grahamfield.com