YHDC SCT010L-D Split Core Current Transformer User Guide

June 1, 2024
YHDC

YHDC SCT010L-D Split Core Current Transformer

Product Information

Specifications :

  • Model: SCT010L-D
  • Characteristic: Safety lock buckle, easy installation, cable output
  • Technical Index:
    • Output/housing AC: 3.5KV/1min 50Hz
    • Rated Input: 5A
    • Rated Output: 10/20/30/50 V DC
    • Accuracy: 1/3/5%
    • Phase Shift: 184 – 45 +8IJUF
    • Weight: 26 – 34 – 10
    • Length of Cable: 100cm – 105cm
    • IP Rating: -3FE
    • Voltage Output Type: g (Secondary is not allowed to short circuit)
    • Opening Angle: 50 – 6 – 2.6

Product Usage Instructions

Installation :

  1. Ensure the safety lock buckle is engaged before installation.
  2. Connect the cable output securely.
  3. Place the product in the desired location and secure it properly.

Electrical Connection:

  1. Connect the input and output cables as per the rated values mentioned.
  2. Avoid short-circuiting the secondary voltage output.

Maintenance:

  1. Regularly check the cable connections for any wear or damage.
  2. Clean the product surface with a dry cloth to remove any dust or debris.

FAQ :

  • Q: Can I shorten the cable length?
    A: The cable length should be maintained between 100cm to 105cm for proper functioning.

  • Q: What should I do if the safety lock buckle is not engaging?
    A: Ensure that the installation is done correctly and contact customer support for assistance if needed.

SCT010L-D
Product picture :(the printed words are for reference only, subject to the actual product)

Characteristic

Safety lock buckle, easy installation, cable output.

Technical index

  • Mounting type: Free hanging (In-Line)
  • Material of core:Ferrite
  • Applicable standards:GB20840-2014
  • Operating temperature:-25℃~+60℃
  • Storage temperature:-30℃~+90℃
  • Frequency range:50Hz-1KHz
  • Dielectric strength:Input (bare conductor)/Output AC 800V/1min 50Hz
  • Output/housing AC 3.5KV/1min 50Hz

Electrical parameters

(The following parameters are typical values and actual values will be subject to product testing)

Rated input| 5| 10| 20| 30| 50| A| Specifications of cable: 2 x 0.2mm² two core sheathed cable
The length of cable : 100cm~105cm Voltage output type
Secondary is not allowed to short circuit
---|---|---|---|---|---|---|---
Rated output| 1/3/5| V/ DC
Accuracy| 2| %
Phase shift| ≤184 ′| ′
Weight| 45| g

Dimensions(in mm±0.5)

YHDC-SCT010L-D-Split-Core-Current-Transformer-03

www.poweruc.pl

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

YHDC User Manuals

Related Manuals