Nightworks IP20 So Pendant Hand Finished Brass Components Installation Guide

June 1, 2024
Nightworks

Nightworks IP20 So Pendant Hand Finished Brass Components

Nightworks-IP20-So-Pendant-Hand-Finished-Brass-Components-
PRODUCT

Specifications

  • Product: SO PENDANT (IP20) V.23.05
  • Installation: Low voltage – Do not wire light fitting directly to mains power
  • Driver: TCI Mini Jolly 125400 550mA Constant Current
  • Minimum cut-out hole diameter: 55 mm
  • Size: 111 x 22 x 52 mm
  • Plastic case: IP20 rated
  • Input Voltage: 1 20V – 240V

Product Usage Instructions:

Stage 1: Install Driver

  1. Select a suitable location for the driver and affix it to a solid surface.
  2. Unscrew the terminal cover and check the DIP switches setting.
  3. Set the DIP switches to the required position as indicated in the manual.
  4. Ensure the mains supply is switched off and connect the Load and Neutral supply to the driver.
  5. Terminate earth connection if present.
  6. Run a 2x core cable from the SEC output on the driver to the luminaire location or connect the luminaire to the driver if located behind it.
  7. If dimming is needed, connect leads for 1-10V or Push Dimmer (not provided).
  8. Reattach the terminal cover securely.

Stage 2: Install Fitting

  1. Wear gloves when handling natural brass products.
  2. Ensure the light fitting is not wired directly to mains power.
  3. Follow the instructions for installing the driver from Stage

FAQ

Q: Can I wire the light fitting directly to mains power?

A: No, it is advised not to wire the light fitting directly to mains power. Follow the installation guide provided.

Q: Do I need to wear gloves when handling the product?

A: Yes, it is recommended to wear gloves when handling natural brass products for safety purposes.

LOW VOLTAGE – Do not wire light fitting directly to mains power.

Installation guide

DANGER electric shock risk. Installation must be conducted by a licensed electrician.

  • STAGE 1: INSTALL DRIVER
    • TCI Mini Jolly 125400
    • 550mA Constant Current
    • Minimum cut-out hole diameter: 55 mm
    • Size: 111 x 22 x 52 mm
    • Plastic case: IP20 ratedNightworks-IP20-So-Pendant-Hand-Finished-Brass-Components-FIG-1
  1. Select driver location, ideally a remote location that is accessible such as an attic or cupboard. Affix the driver to a solid surface.
  2. Unscrew the terminal cover and unclick from the sides.
  3. Check DIP switches are set to the required position if not, set to a pattern as shown above using a small screwdriver.
  4. Ensure the mains supply is switched off. Connect 120V-240V Load and Neutral supply to the left side of the driver as shown.
  5. Terminate earth if present.
  6. Option A: While at the framing stage, run a 2x core cable from the SEC output on the driver to the desired position of the luminaire.
    • Option B: If the driver must be located behind the luminaire. Connect +/- from the LED luminaire to the right side of the driver in the SEC output.
  7. (Optional, not supplied) If dimming is required, connect leads for 1-10V or Push Dimmer as illustrated.
  8. Reattach the terminal cover and screw closed.

STAGE 2: INSTALL FITTING

  • Ensure gloves are worn when handling natural brass products.
  • LOW VOLTAGE – Do not wire light fitting directly to mains power.

STEP 1:

  • Remove all items from the box.
  • Install the driver as shown on the opposite page.
  • Drill <50mm hole in the ceiling at a desired location of the luminaire and locate +/- power from the driver output.
  • Unscrew the brass ring from the canopy to detach the ceiling plate. Slot brass ring and canopy onto the tube.
  • Install ceiling plate and affix to timber joist behind plasterboard.
  • Adjust tube length to suit and secure with m6 grub screw.
  • Pull wires through the designated slot in the ceiling plate and wire with WAGO connectors. Once connected tuck wires back into the ceiling.
  • Slot canopy into place and fix with brass ring.Nightworks-IP20-So-Pendant-Hand-Finished-Brass-Components-FIG-2

STEP 2:

  • Carefully slot the LED module onto the brass tube. (If this is pre-attached please ensure this fitting is firmly in place)

STEP 3:

  • Carefully screw the glass diffuser onto a module.

STEP 4:

  • Wipe down the fitting with the supplied dry cloth.
  • Test fitting.

WARRANTY & CARE

CONTACT US

Documents / Resources

| Nightworks IP20 So Pendant Hand Finished Brass Components [pdf] Installation Guide
IP20 So Pendant Hand Finished Brass Components, IP20, So Pendant Hand Finished Brass Components, Pendant Hand Finished Brass Components, Hand Finished Brass Components, Finished Brass Components, Brass Components
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals