SEALEY 9333-10 Valved Fold Flat Mask
INSTRUCTION MANUAL
DISPOSABLE FACE MASKS
MODEL NO’S: 9329/3 & /10 (PACKS OF 3 & 10), 9309/3 & /10 9331/3 & /10, 9304/3 & /10, 9305/3 & /10, 9332/3 & /10, 9333/3 & /10 9334/3 & /10
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
-
A properly selected face mask is essential to protect your health. Before commencing any task, please consult with qualified safety
personnel to ensure that the face mask type and rating offers adequate protection for your intended use. -
DO NOT use for fire fighting. These respirators DO NOT supply oxygen. DO NOT use in oxygen deficient atmospheres e.g. tanks or
other poorly ventilated areas (see Limitations to use section). -
DO NOT use in explosive atmospheres.
-
For use only by trained and qualified personnel. Requirements for leak tightness are unlikely to be achieved if the respirator is worn
against a beard or facial stubble. -
When transporting this product, retain in the original packaging and keep away from mechanical and chemical hazards.
WARNING! DEVICES MARKED “NR” SHALL NOT BE USED FOR MORE THAN ONE SHIFT.
2. INTRODUCTION
Pack of disposable masks class FFP1/2/3 NR (see individual packaging). Protects against non-toxic dusts and water-based aerosols. Filter Efficiency ≥ 80%. Manufactured to BS EN 149:2001 + A1:2009. PLEASE REFER TO APPLICATIONS
TABLE OVERLEAF.
MODEL NO. | FFP CLASSIFICATION |
---|---|
9329 | FFP1 NR |
9309 | FFP1 NR |
9331 | FFP1 NR |
9304 | FFP2 NR |
9305 | FFP2 NR |
9332 | FFP2 NR |
9333 | FFP3 NR |
9334 | FFP3 NR |
3. DIRECTIONS FOR USE
3.1. Fit the respirator and check leak tightness BEFORE entering the
contaminated area.
3.2. Wear the respirator for the whole duration of the exposure to
contaminants.
3.3. Use the respirator in accordance with applicable Health and Safety
Regulations.
3.4. Discard the respirator and replace with a new one if:
– the respirator is removed while in a contaminated area.
– excessive clogging of the respirator causes breathing difficulty or
discomfort.
– the respirator becomes damaged.
– (for respirators protecting against vapours; discard if the smell of vapours
present becomes detectable).
3.5. Leave the contaminated area if dizziness, irritation or other distress
occurs.
3.6. Only for single use. No maintenance necessary. DO NOT store and/or reuse
after single use.
3.7. Discard the respirator after single use (one shift maximum).
4. FITTING INSTRUCTIONS
NOTE: it is unlikely that the requirements for leakage will be achieved if facial hair passes under the face seal.
4.1. Cup the respirator in the hand, allowing the headbands to hang freely.
4.2. Hold the respirator under chin with nose piece facing outwards.
4.3. Place the lower headband around the neck below the ears. Holding the
respirator against the face with one hand, place the top headband above the
ears, around the crown of the head.
4.4. Respirators with adjustable headbands only: while maintaining the
position of the respirator, adjust tension by pulling tab of each headband.
(Tension may be decreased by pushing out on the back of the buckle).
4.5. Mould the nose area to the shape of the face, running the fingertips of
both hands from the top of the nose piece down both sides whilst pressing
inwards.
4.6. CHECK FOR LEAK TIGHTNESS AS FOLLOWS:
– Place both hands over the respirator and exhale sharply, positive pressure
should be inside the respirator. If air is felt escaping around the edges
readjust the respirator by tightening the nose piece and/or increasing the
tension of the headbands.
– Repeat the procedure until satisfactory face fit has been achieved.
IMPORTANT In the case of respirators with non adjustable headbands if the headbands are too loose tension can be increased by tying a small knot in the headband.
5. STORAGE
5.1. Keep unused respirators in their closed box and store and transport in a dry, non-contaminated area between -20 +50°C at relative humidity below 75%.
6. EXPIRY DATE
6.1. Period of obsolescence is 3 years from date of manufacture (refer to
manufacturing and
expiry date on packaging.
7. LIMITATIONS TO USE
- DO NOT use these respirators or enter/stay in an area where:
– oxygen concentration is less than 19%.
– contaminants or their concentrations are immediately dangerous to life or health.
– particulate concentrations exceed levels fixed by applicable health and safety regulations or protection factor x NPF whichever is lower (Nominal protection factors 4.5 for FFP1, 12.5 for FFP2 and 50 for FFP3).
8. APPLICATIONS TABLE
Dust mask grade | FFP1 | FFP2 | FFP3 |
---|---|---|---|
Protection: | Non-toxic dust and/or water based |
aerosols.
Minor dust level.| Mild toxic or irritant, solid & liquid aerosols.
Moderate dust level.| Toxic liquids, solids & liquid aerosols.
High dust level.
Application:| Handling rubble, sweeping, drilling concrete.| Plastering,
sanding rust & soft wood, grinding & cutting metal, paint spraying
(excluding 2-pack isocyanate)| Paint stripping, sanding of hardwood or
cement, copper, chrome or arsenic, welding.
Substance:| Flour, chalk, graphite, cotton, concrete.| Untreated softwood,
coal, powder
pesticide, fibreglass.| Biological, pharmaceutical, chrome, lime, lead,
asbestos (non- handling).
Filter efficiency:| ≥80%| ≥94%| ≥99%
- The application guide is given as an indication only. Before commencing with any task, please consult with qualified safety personnel, or carry out your own risk assessment, to ensure that the face mask type and rating offers adequate protection for your intended use.
You may need to use this mask in conjunction with other safety equipment. These are particulate filters only, and do not provide protection from harmful fumes or gases.
9. APPROVAL
9.1. Our disposable particulate respirators have been tested and certificated by the BSI Group The Netherland B.V. NB 2797, Say Building, John M. Keynesplein 9, 1066 EP Amsterdam, The Netherlands for EU type Examination, or BSI Assurance UK Ltd. AB 0086, Kitemark Court – Davy Avenue, Knowlhill, Milton Keynes, MK5 8PP for UKCA conformtity assesment – U K.
The filtering half mask produced true (EU) 2016/425, standards from EN 149: 2001 + A1: 2009 FFP1, FFP2 and FFP3 NR , UKCA and CE marked.
This document has been drawn up according to Regulation (EU) 2016/425 as amended to apply to GB for Personal Protective Equipment. The declaration of conformity can be accessed at www.sealey.co.uk.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is
required for any claim.
EU | Sealey EU Ltd, Farney Street, Carrickmacross, Co. Monaghan, A81 PK68
Ireland
UK | Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds,
Suffolk. IP32 7AR
01284 757500
sales@sealey.co.uk
www.sealey.co.uk
© Jack Sealey Limited
Specifications:
-
Model Numbers: 9329/3 & /10, 9309/3 & /10, 9331/3 &
/10, 9304/3 & /10, 9305/3 & /10, 9332/3 & /10, 9333/3
& /10, 9334/3 & /10 -
Class: FFP1/2/3 NR
-
Filter Efficiency: 80%
-
Manufactured to: BS EN 149:2001 + A1:2009
-
-
FAQ:
Q: Can the face masks be reused?
A: No, the face masks are designed for single-use only and should be discarded after use.
Q: What is the recommended filter efficiency of the masks?
A: The masks have a filter efficiency of 80%.