“`html
Specifications
- Product Name: Wired Controller ACCD_WC1
- Model: ACCD_WC
- Date: 06/23
Product Information
Thank you for choosing our product. For proper operation, please
read and keep this manual carefully. If you have lost the Owner’s
Manual, please contact the local agent or visit
sat.eurofredgroup.com.
User Notices
-
Prohibit installing the wired controller at wet or sunshine
places. -
Do not knock, throw or frequently disassemble the wired
controller. -
Do not operate the wired controller with wet hands.
-
Do not remove or install the wired controller by yourself. If
there is any question, please contact our after-sales service
center. -
The wired controller is a general model, applicable for several
kinds of units.
Product Usage Instructions
1. Display
1.1 Appearance
Refer to Fig.1 for the appearance of the wired controller.
1.2 Instructions for Related Displayed Symbols
No. | Symbols | Instructions |
---|---|---|
1 | Up and down swing function | … |
2. Buttons
2.1 Button Graphics
Refer to Fig. 2 for button graphics.
2.2 Function Instructions of Buttons
No. | Button name | Button Function |
---|---|---|
1 | FAN | Set low speed, low-medium speed, medium speed, medium-high |
speed, high speed, turbo and auto speed.
3. Operation Instructions
Include detailed operation instructions here.
4. Installation Instructions
4.1 Parts and Dimension of Wired Controller
Details about parts and dimensions.
4.2 Installation Requirements
Requirements for installing the wired controller.
4.3 Installation Methods
Different methods for installing the wired controller.
4.4 Disassembly
Steps for disassembling the wired controller if needed.
FAQ
Q: Can I install the wired controller in a wet
environment?
A: No, it is prohibited to install the wired controller in wet
or sunshine places.
“`
INSTALATION MANUAL USER MANUAL
WIRED CONTROLLER ACCD_WC1
Série
ACCD_WC
Édition
06/23
Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner’s Manual, please contact the local agent or visit sat.eurofredgroup.com.
User Notices
For correct installation and operation, please read all instructions
carefully. Before reading the instructions, please be aware of the following
items:
Prohibit installing the wired controller at wet or sunshine places. Do not
knock, throw or frequently disassemble the wired controller. Do not operate
the wired controller with wet hands. Do not remove or install the wired
controller by yourself. If there is any
question, please contact our after-sales service center. The wired controller
is a general model, applicable for several kinds of units.
Some functions of the wired controller are not available for certain kinds of
units, more details please refer to the owner’s manual of unit. The setting of
such unavailable function will not affect unit’s operation.
Contents
1 Display ……………………………………………………………………….. 1
1.1 Appearance…………………………………………………………………….1 1.2 Instructions for Related
Displayed Symbols…………………………2
2 Buttons ………………………………………………………………………. 3
2.1 Button Graphics ………………………………………………………………3 2.2 Function Instructions of
Buttons…………………………………………4
3 Operation Instructions……………………………………………………4
3.1 Menu Structure………………………………………………………………..4 3.2
On/Off…………………………………………………………………………….5 3.3 Mode
Setting…………………………………………………………………..6 3.4 Temperature
Setting…………………………………………………………7 3.5 Fan Setting……………………………………………………………………..7
3.6 Swing Setting ………………………………………………………………….7 3.7 Functions Setting
…………………………………………………………..10 3.8 Unit Status View …………………………………………………………….18 3.9
Current Error View …………………………………………………………20 3.10 Timer
Setting……………………………………………………………….22 3.11 Clock Setting
……………………………………………………………….31
3.12 Lock Setting ………………………………………………………………..33
4 Installation Instructions ……………………………………………….. 34
4.1 Parts and Dimension of Wired Controller…………………………..34 4.2 Installation
Requirements………………………………………………..35 4.3 Installation Methods
……………………………………………………….36 4.4 Disassembly………………………………………………………………….37
1 Display
1.1 Appearance
Fig.1 Appearance of wired controller 1
1.2 Instructions for Related Displayed Symbols
No.
Symbols
Instructions
1
Up and down swing function
2
Left and right swing function
3
Fresh air function
4
Sleep function
5
Auto mode
6
Cooling mode
7
Dry mode
8
Fan mode
9
Heating mode
10
Health function
11
I-Demand function
12
Absence function
13
Shielding status (Buttons, temperature, ON/OFF, mode or energy saving is shielded by remote monitor)
14
Current set fan speed
15
Memory function (Memory in power failure)
16
Save function
17
X-fan function
2
18 19 20 21 22
2 Buttons
Remind to clean the filter Timer on status Gate card pulled-off status or nobody presented status Quiet function Function lock
2.1 Button Graphics
Fig. 2 Button graphics 3
2.2 Function Instructions of Buttons
No.
Button name
Button Function
1
FAN
Set low speed, low-medium speed, medium speed, medium-high speed, high speed, turbo and auto speed.
2
(1) Set temperature
(2) Set parameter
6
(3) Move option cursor
3
ON/OFF/BACK
(1) Turn on or turn off unit (2) Return to last page
4
SWING
Set up&down swing and set left&right swing
5
(1) Set related function on or off
(2) Move option cursor
8
(3) Set parameter
7
MENU/OK
(1) Enter menu page (2) Confirm setting
9
MODE
Set auto, cooling, dry, fan and heating modes for indoor unit.
3 Operation Instructions
3.1 Menu Structure
Normal setting of wired controller can be set directly on the main page, including fan speed, swing, set temperature, mode, ON/OFF. The setting and status view of other functions can be set in corresponding submenu. Detailed menu structure is as shown in Fig. 3.
4
3.2 On/Off
Fig. 3 Menu structure
When the wired control is on main page, press ON/OFF button to turn on the
unit. Press ON/OFF button again to turn off the unit. The interfaces of On/Off
status are shown in Fig. 4 and Fig. 5.
5
Fig. 4 Off interface
3.3 Mode Setting
Fig. 5 On interface
Under On status, pressing MODE button can set mode circularly as:
Note: If save function is on, auto mode is not available.
6
3.4 Temperature Setting
Under unit on status, pressing “” or “” button on the main page increases or
decreases set temperature by 1(1); holding “” or “” button increases or
decreases set temperature by 1(1) every 0.3s.
In cooling, dry, fan and heating mode, temperature setting range is 16~30
(6186). Under auto mode, set temperature cannot be adjusted.
3.5 Fan Setting
Under On status, pressing FAN button can set fan speed circularly as:
LowMedium lowMediumMedium highHighTurboAutoLow Symbols displayed are as shown
in Fig. 6.
3.6 Swing Setting
Fig. 6 Fan setting
In unit on status, press SWING button for swing setting. Two swing modes are
available: fixed-angle swing and simple swing.
When fixed-angle swing mode is set, swing operation is as follows: In unit on
status, press SWING button to select up&down swing . Up&down swing angle will
be adjusted circularly as below:
7
closed
Select up&down swing and left&right swing through “” or “” button. When
left&right swing
is selected. Left&right swing angle will be adjusted circularly as
below:
closed
Note: Turn on fixed-angle swing mode in function setting page. If fixed-angle swing is not available for the model, fixed-angle swing will be invalid when the wired controller turns on fixed-angle swing mode.
Simple swing mode: when fixed-angle swing mode is turned off, swing operation is as below:
Pressing SWING button under unit on status, up&down swing frame occurs. Then press SWING button to turn on or turn off up&down swing. is displayed
when up&down swing is on and is not displayed when up&down swing is off. When up&down swing frame have not disappeared, press “” or “” button to switch to
left&right swing setting. Then left&right swing frame occurs. In this case, press
SWING button to turn on or turn off left&right swing.
is displayed when left&right
swing is on and is not displayed when left&right swing is off. For detailed operation,
please refer to Fig. 7.
8
9
Fig. 7 Swing setting
3.7 Functions Setting
Press MENU/OK button on main page to enter main menu page. Press “” or “” or
“” or “” button to select the function setting symbol. Then press MENU/OK
button to enter user function setting page. Press “” or “” button to select
specific function item. Press “” or “” button to turn on or turn off this
function. If the function item cann’t be set, it will displays with gray
color.Please refer to Fig. 8.
10
Fig. 8 Function setting 11
3.7.1 Fresh Air Function Setting
After entering user function page, press “” or “” button to select fresh air
function and press “” or “” button to turn on or turn off air function. Press
MENU button to adjust the mode of fresh air.
After entering fresh air mode setting, press “” or “” button to adjust the
mode in the range of 1~10. After setting, press MENU button to save the
setting.
The each mode means as follows: 1The unit continuously runs for 60min, and
fresh air valve runs for 6 min. 2The unit continuously runs for 60min, and
fresh air valve runs for 12 min. 3The unit continuously runs for 60min, and
fresh air valve runs for 18 min. 4The unit continuously runs for 60min, and
fresh air valve runs for 2 4 min. 5The unit continuously runs for 60min, and
fresh air valve runs for 30 min. 6The unit continuously runs for 60min, and
fresh air valve runs for 36 min. 7The unit continuously runs for 60min, and
fresh air valve runs for 42 min. 8The unit continuously runs for 60min, and
fresh air valve runs for 48 min. 9The unit continuously runs for 60min, and
fresh air valve runs for 54 min. 10The unit continuously runs for 60min, and
fresh air valve always runs.
3.7.2 Sleep Function Setting
After entering user function page, press “” or “” button to select sleep
function and press “” or “” button to turn on or turn off sleep functio1n with
auto
12
saving. If this function is turned on, the unit will operate according to the
preset sleep
curve to provide comfortable sleep environment. Note:
In fan or auto mode, sleep function is not available; Sleep function will be
cancelled when turning off the unit or switching modes.
3.7.3 Health Function Setting
After entering user function page, press “” or “” button to select health
function and press “” or “” button to turn on or turn off health function with
auto saving.
3.7.4 I-DEMAND Function Setting
After entering user function page, press “” or “” button to select IDEMAND
function option and press “” or “” button to turn on or turn off this function
with auto saving. Note:
This function is only available in cooling mode. When this function has been
set, set temperature is displayed in 27(81).
In this case, temperature setting and fan speed setting are shielded. This
function will be cancelled when turning off the unit or switching modes. This
function and sleep function cannot be on simultaneously. If I-demand
13
function is set firstly and then sleep function is set, I-demand function will
be cancelled while sleep function will be valid, and vice versa.
3.7.5 Absence Function Setting
After entering user function page, press “” or “” button to select holiday
function option and press “” or “” button to turn on or turn off this function
with auto saving.
This function is used to maintain indoor temperature so that unit can realize
fast heating. Note:
This function is only available in heating mode; When this function has been
set, set temperature is displayed in 8(46).
In this case, temperature setting and fan speed setting are shielded; This
function will be cancelled when switching modes; This function and sleep
function cannot be on simultaneously. If absence
function is set firstly and then sleep function is set, absence function will
be cancelled while sleep function will be valid, and vice versa.
3.7.6 Memory Function Setting
After entering user function page, press “” or “” button to select memory
function and press “” or “” button to turn on or turn off memory function with
auto saving.
14
3.7.7 Save Function Setting
After entering user function page, press “” or “” button to select save
function and press “” or “” button to turn on or turn off save function. Press
MENU button to enter save function setting page.
After entering save function setting page, press “” or “” button to select
cooling or heating limitation temperature. After selecting cooling or heating
limitation temperature, press “” or “” button to adjust limitation temperature
value. After setting, press MENU button to save the setting. Note: When save
function has been set, auto mode cannot be set.
3.7.8 Auxiliary Heating Function Setting
After entering user function page, press “” or “” button to select auxiliary
heating function and press “” or “” button to turn on or turn off this
function with auto saving.
3.7.9 X-fan Function Setting
After entering user function page, press “” or “” button to select dry
function option and press “” or “” button to turn on or turn off this function
with auto saving.
Note: This function is only available in cooling mode and dry mode; When this
function is on, if the air conditioner is turned off, the indoor fan will
still operate at low speed for a while to blow the residual water inside the
air duct.
15
3.7.10 Quiet Function Setting
After entering user function page, press “” or “” button to select quiet
function and press “” or “” button to turn on or turn off this function with
auto saving. Note: This function is only available in cooling mode, heating
mode and auto mode.
3.7.11 Filter Clean Reminder Setting
After entering user function page, press “” or “” button to select clean
function option and press “” or “” button to turn on or turn off this
function. Press MENU button to enter the setting page of filter clean reminder
function.
After entering the setting page of filter clean reminder function, press “” or
“” button to select pollution level and then press “” or “” button to set
pollution level; press “” or “” button to select accumulating time setting and
then press “” or “” button to set required time. After setting, press MENU
button to save the setting.
When level 1 is selected, the adjusting range of accumulating operating time
is 5500~10000 hours, with 500 hours in each increase or decrease.
When level 2 is selected, the adjusting range of accumulating operating time
is 1400~5000 hours, with 400 hours in each increase or decrease.
When level 3 is selected, the adjusting range of accumulating operating time
is 100~1000 hours, with 100 hours in each increase or decrease.
This function is used to remind you to clean the filter when the unit’s own
operating time is reach your setting.
16
Whenever you turn off this function, the unit’s operating time will be zero
clearing.
3.7.12 Fahrenheit Temperature Setting
After entering user function page, press “” or “” button to select Fahrenheit
temperature function and press “” or “” button to turn on or turn off this
function with auto saving. After closing this function, Celsius temperature
will be displayed.
3.7.13 Fixed-angle Swing Mode Setting
After entering user function page, press “” or “” button to select lock swing
function option and press “” or “” button to turn on or turn off this function
with auto saving. Note: If fixed-angle swing function is not available for the
connected unit, this function will be cancelled automatically after setting.
3.7.14 Low-temperature Drying Function Setting
After entering user function page, press “” or “” button to select low-
temperature drying function and press “” or “” button to turn on or turn off
this function with auto saving. Note:
This function is only available in dry mode; When low-temperature drying
function is on, the displayed set temperature in
dry mode is 12 (54 ). This function will be off automatically after
17
readjusting set temperature.
3.8 Unit Status View
Press MENU button to enter the menu and select the function symbol to be
viewed. Then press MENU button to enter view function page. Press “” or “”
button to select status view function. Press MENU button to enter unit status
view page. Press BACK button to return to the last page. Please refer to Fig.
9.
The following statuses can be viewed: if defrosting is operating; if auxiliary
heating is operating; residual time of filter cleaning reminder; indoor
ambient temperature; outdoor ambient temperature.
18
Fig. 9 Status View 19
3.9 Current Error View
When error occurs in the unit, error symbol will be displayed on the main page
of wired controller to indicate that the unit is with error. In this case, you
can enter error view page to view the current error.
Press MENU button to enter the menu and select the function symbol to be
viewed. Then press MENU button to enter view function page. Press “” or “”
button to select error information. Press MENU button to enter error view
page. If there are too many errors, press “” or “” to turn pages. Press BACK
button to return to the last page. Please refer to Fig. 10.
20
Fig. 10 Current Error View 21
3.10 Timer Setting
The wired controller can set 6 kinds of timer: one time clock timer, everyday
timer, one week timer, two week timer, countdown timer on and countdown timer
off. Select timer symbol after entering menu page. Press MENU button to enter
timer setting page. Press “” or “” button to select one kind of timer. Press
“” or “” button to turn on or turn off this timer. Please refer to Fig. 11.
Fig. 11 Turn on or turn off timer
3.10.1 One Time Clock Timer
The wired controller can set one time clock timer. If the unit is off, timer
on can be set. If the unit is on, timer off can be set. This timer will be
carried out for only once
22
when timer time is reached and then the timer will be off automatically. In
timer function setting page, when one time timer is selected, press “” or “”
button to turn on or turn off this timer function. Press MENU button to enter
timer time setting page, as shown in Fig. 12.
Press “” or “” button to select timer hour or minute and press “” or “” button
to adjust time. Holding “” or “” button increases or decreases time rapidly.
After finishing setting, press MENU button to save timer time.
Fig. 12 Setting page of one time clock timer Note: If this timer function is
turned on, when the unit is turned on or turned off, this timer function will
be cancelled automatically.
23
3.10.2 Daily Timer
In daily timer, user can set eight segments of timer individually. The
individual segment will be valid only when it is turned on. In each segment,
you can set time, unit ON/OFF, set temperature in cooling (it is valid only
when the current mode is cooling), set temperature in heating (it is valid
only when the current mode is heating). Please refer to Fig. 13.
After entering daily timer setting page, press “” or “” button to select
setting item. Press “” or “” button to adjust the value. Press MENU button to
save setting.
Fig. 13 Daily timer setting 24
3.10.3 Weekly Timer
The user can set the everyday timer content for a week. In each day, the user
can set eight segments of timer content. The unit will execute corresponding
timer setting in a week.
After entering weekly timer setting page, press “” or “” button to select the
day to be set. Then press MENU button to enter timer programming of that day.
Press “” or “” button to select the item to be set. Press “” or “” button to
adjust the content. Press MENU button to save setting. Please refer to Fig.
14.
25
26
Fig. 14 Weekly timer setting
3.10.4 Two Week Timer
The user can set the everyday timer content for two weeks. In each day, the
user can set eight segments of timer content. The unit will execute
corresponding timer setting in two weeks.
In timer function setting page, press “” or “” button to select two week timer
setting and then press MENU button to enter two week timer menu page. Press “”
or “” button to select current week option and then press “” or “” button to
set
27
current week as first week or second week. Press MENU button to save current
week setting. Please refer to Fig. 15.
Fig. 15 Setting of current week After entering two week timer menu page, press
“” or “” button to select the two week schedule option and then press MENU
button to enter two week timer programming. After entering two week timer
setting page, press “” or “” button to select the day to be set. Then press
MENU button to enter timer programming of that day. Press “” or “” button to
select the item to be set. Press “” or “” button to adjust the content. Press
MENU button to save setting. Press BACK button to exit this page. The setting
symbols please refer to weekly timer setting.
28
3.10.5 Countdown Timer
Countdown timer includes timer on and timer off. Unit On/Off after a desired
hour can be set. In unit on status, timer off can be set, or timer off and
timer on can be set simultaneously. In unit off status, timer on can be set,
or timer off and timer on can be set simultaneously. If timer off in x hours
and timer on in y hours are set simultaneously in unit on status, the unit
will be off in x hours and then the unit will be on in y hours after timer
off.
After entering timer on setting page, press “” or “” button to increases or
decreases timer time by 0.5h. Press BACK button to return to the last page.
Please refer to Fig. 16.
Fig. 16 Countdown timer on 29
After entering timer off setting page, press “” or “” button to increases or
decreases timer time by 0.5h. Press BACK button to return to the last page.
Please refer to Fig. 17.
Fig. 17 Countdown timer off If timer function is on, the set hours will
decrease as the unit operation time increases. In this case, residual hours
can be viewed after entering timer setting page. This timer function will be
carried out for only once and then it will be cancelled automatically. Note:
If this timer function is turned on, when the unit is turned on or turned off,
this timer function will be cancelled automatically.
30
3.11 Clock Setting
3.11.1 Time Format Setting
The user can set the time format in 12-hour system or 24-hour system. Select
clock symbol in menu page and then press MENU button to enter clock setting
page. Press “” or “” button to select time format and then press “” or “”
button to select 12-hour system or 24-hour system. Please refer to Fig. 18.
Fig. 18 Time format selection
3.11.2 Clock Setting
Select clock symbol in menu page and then press MENU button to enter clock
setting page. Press “” or “” button to select time set and then press MENU
button to enter time setting.
31
Press “” or “” button to select setting items: hour, minute, year, month, day;
press “” or “” button to set the value and then press MENU button to save
setting. Please refer to Fig. 9.
Fig. 19 Clock setting 32
3.12 Lock Setting
Select lock symbol in menu page and then press MENU button to enter lock
setting page. Press “” or “” button to select the item to be locked and then
press “” or “” button to lock or unlock. Please refer to Fig. 20.
Items can be locked: ON/OFF, mode setting, temperature setting, fan speed
setting, key lock. After locking, the corresponding item cannot be set through
buttons.
If the keys are locked, all keys cannot be operated after returning to the
main page. Please unlock according to the instructions on main page. During
unlocking, press MENU button, press “” button and then press “” button to
unlock keys.
Fig. 20 Lock setting 33
4 Installation Instructions
4.1 Parts and Dimension of Wired Controller
Fig. 21 Dimension of wired controller
Fig. 22 Parts of wired controller 34
No. Name Quantity
1
Panel of wired controller
1
2 Screw M4X25
3
3
Soleplate of wired controller
1
4.2 Installation Requirements
(1) Prohibit installing the wired controller at wet places; (2) Prohibit
installing the wired controller at the places with direct
sunshine; (3) Prohibit installing the wired controller at the place near high
temperature objects or water-splashing places.
35
4.3 Installation Methods
Fig. 23 Installation diagram for wired controller Fig. 23 is the simple
installation process of wired controller; please pay attention to the
following items: (1). Before installation, please cut off the power for indoor
unit; (2). Pull out the 2-core twisted pair wire from the installation hole on
wall, and pull
36
this wire through the ” ” hole at the rear side of the soleplate of wired
controller; (3). Stick the soleplate of wired controller on the wall and then
use screw M4×25
to fix soleplate and installation hole on wall together; (4). Connect two-core
twisted pair wire to H1 and H2 wiring column and then fix
the screws (it is needn’t to differentiate polarity.); (5). Block the two-core
wire into the groove at the left side of wiring column;
bundle the front panel of wired controller to its soleplate. Note: If the
procedures in point 2 and point 5 mentioned above is hard to be done as the
diameter of selected communication wire is big, please peel off the sheathed
layer in appropriate length according to actual situation.
4.4 Disassembly
Fig. 24 Disassembly diagram for wired controller
37
lll llllll111 11111111111111 66170050002
Eurofred S.A.
Marqués de Sentmenat 97 08029 Barcelona www.eurofred.es
References