LUCI KRD202 Inox Shower Bath Diverter Mixer Instruction Manual

June 1, 2024
Luci

INSTALLATION INSTRUCTION
LV.3000

LUCI KRD202 Inox Shower Bath Diverter Mixer -

IMPORTANT!
Please read this instruction Prior to installation

PARTS IDENTIFICATION

LUCI KRD202 Inox Shower Bath Diverter Mixer - figer1

INSTALLATION

LUCI KRD202 Inox Shower Bath Diverter Mixer - figer2

BODY INSTALLATION-

  1. Flush the pipe work thoroughly prior to installation.
  2. Leave plastic cover in place and secure the body to the supporting timber noggin ensuring that it is orientated square and vertical
  3. Connect Hot + Cold water supply and both outlets to the concealed valve. Please ensure outlets are connected correctly.
  4. Pressure test for leaks
  5. Sheet the wall using water resistant board or equivalent. Please refer diagram above.

COVER PLATE INSTALLATION-

  1. Once tiling is complete remove the plastic cover from both the body sleeve + divertor Sleeve
  2. Apply silicone to the back of the cover plate (Part 6) and slide over body (Part 8) + Divertor Housing (Part 12) creating a seal from the cover plate to the finished wall .
  3. Push Handle (Part 3 ) over Cartridge adaption and tighten grub screw (Part 2) firmly
  4. Screw Pin Lever (Part 1 ) into the handle housing and tighten firmly .

NOTE- It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and re-install

IMPORTANT RECOMMENDATIONS FOR INSTALLATION
Installation should comply to AS/NZS3500.1 2003 or relevant local requirement.
Not suitable for gravity feed application.
Hot & cold water inlet pressures should be equal.
WATER PRESSURE
Operating static pressure is 150 – 500kpa. If pressure exceeds this, then an approved pressure limiting valve must be installed.
PRE-FLUSH
Always flush out the pipework before connecting any faucets.
Damage caused to the faucet by debris coming through the pipework is not covered under warranty.
WATER TEMPERATURE
Maximum hot water temperature is 75 degree.

ATTENTION!
Failure to do so will void the warranty.

T 1300 837 688 E [email protected]
www.verotti.com