LUCI LV.7100 Inox Freestanding Bath Filler Installation Guide
- June 1, 2024
- Luci
Table of Contents
LUCI LV.7100 Inox Freestanding Bath Filler
Product Information
Specifications
- Compliance: AS/NZS3500.1 2003
- Water Inlet: Hot & cold water inlets should have equal pressures
- Operating Pressure: 150 – 500kpa
- Maximum Hot Water Temperature: 75°C
Product Usage Instructions
Installation Recommendations:
Ensure compliance with AS/NZS3500.1 2003 or relevant local requirements.
This product is not suitable for gravity feed applications. Hot and cold water
inlet pressures must be equal. If operating static pressure exceeds 500kpa,
install an approved pressure limiting valve.
Pre-Flush:
Before connecting any tapware or faucets, flush out the pipework to prevent
debris from causing damage. Warranty does not cover damage caused by debris
from pipework.
Water Temperature:
Ensure that the maximum hot water temperature does not exceed 75°C to
prevent damage to the product.
LUCI Installation Instruction:
Follow the LV.7100 installation instructions carefully to avoid voiding the
warranty. Prior to installation, read the provided instructions thoroughly.
Care and Use:
- Shut the tap gently to reduce water hammer or banging pipes.
- Clean chrome surfaces regularly with non-scouring, neutral wash solutions only.
FAQ
-
Q: What should I do if the water pressure exceeds the recommended limit?
A: If the water pressure exceeds 500kpa, install an approved pressure limiting valve to ensure safe operation. -
Q: Can the product be used for gravity feed applications?
A: No, this product is not suitable for gravity feed applications. Please ensure proper water pressure for optimal performance.
LUCI INSTALLATION INSTRUCTION
LV.7100
IMPORTANT!
Please read this instruction Prior to installation
T 1300 837 688 E info@verotti.com www.verotti.com
IMPORTANT RECOMMENDATIONS FOR INSTALLATION
Installation should comply to AS/NZS3500.1 2003 or relevant local requirement.
Not suitable for gravity feed application.
Hot & cold water inlet pressures should be equal.
-
WATER PRESSURE
Operating static pressure is 150 – 500kpa. If pressure exceeds this, then an approved pressure limiting valve must be installed. -
PRE-FLUSH
Always flush out the pipework before connecting any faucets.
Damage caused to the faucet by debris coming through the pipework is not covered under warranty. -
WATER TEMPERATURE
Maximum hot water temperature is 75 degree.
ATTENTION!
Failure to do so will void the warranty.
Installation
-
Ensure both supply pipes has been flushed and is free from debris before proceeding.
-
When installing into a concrete floor, a chase will need to be cut out of the concrete to rough in the supply pipe.
Rough in to a spout outlet with a 1/2 inch male BSP thread & cap until fit- off. -
Feed the two flexible hoses through the floor bracket, riser pipe & cover plate. Hand tighten riser pipe into the bracket & slide plate onto riser pipe.
-
Connect the two flexible hoses into the mixer by hand tightening & making a final adjustment with spanner. Hand tighten riser pipe onto mixer.
-
Connect the two flexible hoses into the water supply by hand tightening & making a final adjustment with a spanner.
-
Screw mounting bracket to floor using fixings provided. Slide cover plate down into position.
Care and Use
- Shutting the tap gently will reduce the chance of water hammer or ‘banging’ pipes.
- Regularly clean the chrome surfaces only with non scouring, neutral wash solutions.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>