aqua viva SKRX Smart Rx 1.5 l-h Peristaltic Dosing Pump Instructions

June 12, 2024
aqua viva

ORP PUMP
SKRX Smart Rx 1.5 l-h Peristaltic Dosing

Instructions

General Features

  • Power Supply 220-240 Vac
  • Display 4 digits with 7 segments
  • Bnc connection for probe Redox/ORP
  • Switch 3 position Priming, ON, Stand by
  • Peristaltic pump flowrate and pressure look at label on product
  • Measure Range Redox/ORP: 400÷999 mV (resolution: 10 mV)
  • Dosage method ON-OFF ( Set Point adjustable)
  • Calibration method Redox/ORP 1 Point (465 mV)

Switch position:

  1. Priming position “the pump running” (Switch position MOM)

  2. Normal position “the instrument measure Redox and dosing. (Switch position ON)
    Keep pressed key for 5 seconds to run calibration menu:
    Redox probe: the pump displays C465 press key and wait 60 seconds
    Displays quality probe ex: C100
    Press the button to stop the calibration.
    Keep pressed key until flashing Setpoint value and press again to increase the value.
    After 3 seconds from releasing the key the value will be saved and the pump will display mem. the range of values is included between 400 and +990 mV with an increase of 10 mV.
    When the real measure is less than 400 mV and higher than 999 mV the measure displayed flashes.

  3. Stand by position “The pump is stop” (Switch position OFF)

Keep Press key for 3 seconds to run Setup menu:
Redox setup menu:
Adjust dosage method High (“Hi”) or Low (“Lo”).

ver. 08_2019

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>