Product Information:

Specifications:

  • Product Name: Ledinaire EcoSet
  • Application: Offices
  • Components: Ledinaire EcoSet panel, Ledinaire EcoSet office
    sensor, Power control for the room, Power cabling

Product Usage Instructions:

1. Prepare the Setup for a Group:

  1. Ensure each group of lights has power.

  2. Choose to disconnect the group locally or use the power control
    provided.

  3. Insert batteries in remote control and optional wall
    switch.

  4. Configure settings via dip switches on the sensor.

  5. Install lights according to the lighting plan.

2. Create a Group of Lights:

  1. Turn off the lights in the group for 10 seconds.

  2. Turn the lights back on.

  3. Wait for the sensor LED to turn off (approximately 50
    seconds).

  4. Press buttons on the remote control and sensor to create a new
    group.

  5. Add a wall switch if desired.

3. Test Lights of the Created Group | 3 Options:

  • Press Query button on the remote to make the group blink
    once.

  • Operate lights using the wall switch.

  • Test the sensor by walking out of its range.

4. Troubleshooting:

  1. If setup does not work, open the existing group and follow
    steps for adding sensor or wall switch.

  2. For more troubleshooting advice, refer to the application
    manual at philips.com/ledinaire.

FAQ:

Q: What should I do if the setup fails?

A: Open the existing group and follow steps to add sensor or
wall switch within 2 minutes to avoid setup failure.

“`

Ledinaire EcoSet
Quick start guide
Philips Ledinaire EcoSet for offices
a lighting brand by

Exemplary office area

Meeting room A = Group 1

Meeting room B = Group 2 Corridor = Group 3

2
Ledinaire EcoSet panel Ledinaire EcoSet office sensor Power control for the room Power cabling

1. Prepare the setup for a group

1

2

3

3
4

Make sure that the lighting plan will provide power for each group of lights.
Your options:
1. Have a method to disconnect the group locally or
2. Use the power control shown on the previous page
Independent power control for each group ensures a successful light setup.

Insert batteries in remote control and optional wall switch.

Optional:
Configure the settings via the dip switches on the back of
the sensor.

Remote: 2 × AA Wall switch: 1 × CR2450

Please refer to the mounting instructions of the sensor included in the box.

Install lights as per lighting plan.
You can turn on the lamps to test the electrical connection, but remember to turn off all lamps before the next step.

4
2. Create a group of lights

1

2

3

4

5

1. Turn the lights in the group off for 10 seconds. Make sure that no other lights are switched on.
2. Turn the lights back on
The red LED in the sensor unit lights up to indicate that the sensor is being powered up.
Wait until the sensor LED is turned off. This will take about 50 seconds.

Create a new group
+ COM
Press the above buttons on the remote control for 10 seconds.
The red LED on the remote will light up.
The lights will dim quickly and return to 100% within 2 minutes.
No need to wait, let’s continue!

Add a sensor
Shortly press the above button on the sensor.
The LED on the sensor will blink for 1 minute while it searches for and connects to the group.
No need to wait, let’s continue!

Optional step: Add a wall switch
ON + +
Press the above buttons on the wall switch for 10 seconds.
The wall switch will search for and connect to the group.

Your group is ready when the red LED on the remote turns off. This will take 2 minutes.
To force closure before 2 minutes have passed, press and hold the above button until the red light goes out.
Follow the instructions for testing the lights on the next page.

Execute these steps within 2 minutes, otherwise the setup will fail! Execute these steps within 2 minutes, otherwise the setup will fail!

5
3. Test lights of the created group | 3 options

1

Or

2

Or

3

Test lights in the group
QUERY
Press the “Query” button on the remote to make the current group blink once.

Test the wall switch
Press “ON/OFF” or “+/-” buttons to operate the lights.
Please note: After operating the wall switch the hold time is extended by 30 minutes. Switch the light off and on again to be able to test the sensor immediately.

Test the sensor
Walk out of the room/sensor range.
Lights will dim after hold time, and switch off after 15 mins.

6
If the new setup does not work

1

2

Open the existing group
Press and hold the above button on the remote control. The red LED on the remote will light up for 2 minutes.
For more troubleshooting advice, refer to the application manual at philips.com/ledinaire
© 2023 Koninklijke Philips N.V. All rights reserved. www.philips.com

Add sensor or wall switch
Follow the steps as described on page 4.
Add the devices within 2 minutes, otherwise the setup will fail!

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals