FKM6016D Digital Clamp Meter User Manual
- June 1, 2024
- FKM
Table of Contents
FKM6016D Digital Clamp Meter
“`html
Specifications:
- Model No.: FKM6016D
- Measurement Units: % mV, V A nF, FmF, k, M, Hz, kHz, MHZ
- Features: Automatic range mode, Voltage test mode, Current test
mode, Frequency test mode, Buzzer, Resistant measurement, DIODE
TEST MODE, Capacitance test mode, Current Am test mode, Temperature
mode, NCV test mode, Fire live test mode, Auto power off indicator,
Data hold on NCV and fire live indicator, DC AC, Relative value,
Percentage (duty cycle), MV, volts (voltage), Ampere (current),
Nafala, microfarads, cents Farah Ohm, kilohm, megohm (resistance),
Hertz, kilohertz, megahertz (frequency)
Product Usage Instructions:
Electric Shock Hazard Warning:
An electric shock hazard exists in current clamp measurements.
Follow these steps to ensure safety:
-
Hold the trigger and test lead the clampA wire line is measured
clip in the meter. -
Read the current value displayed on the LCD.
-
Avoid clamping two or more wires of the circuit under test
simultaneously. -
For accurate results, do not test two or more wires at the same
time. -
Conduct measurements when the relative humidity is less than
75% for accurate readings.
Overview:
The product offers a wide range of measurement modes and
features for various testing needs. Make sure to follow safety
precautions and guidelines provided in the manual.
FAQ:
Q: How do I switch between different measurement modes?
A: Use the mode selector button on the device to switch between
voltage test mode, current test mode, frequency test mode, and
other available modes.
Q: Can this product be used for testing diodes?
A: Yes, the product includes a DIODE TEST MODE for diode
testing. Follow the instructions in the manual for proper diode
testing procedures.
“`
Model No. FKM6016D
% mV, V A nF,FmF
, k, M
Hz, kHz MHZ
Automatic range mode Voltage test mode Current test mode Frequency test mode
Buzzer Resistant measurement DIODE TEST MODE Capacitate test mode Current Am
test mode Temperature mode NCV test mode Fire live test mode Auto power off
indicator Data hold on NCV and fire live indicator DC AC Relative value
Percentage (duty cycle) MV, volts (voltage) Ampere (current) Nafala,
microfarads, cents Farah Ohm, kilohm, megohm (resistance) Hertz, kilohertz,
megahertz (frequency)
07
of the current clamp. 4″ ” Represents the maximum input ac current of 600 A.
5Please hold the clamp head when the current measurement machine to open the
clamp head and nose pliers head clip conductor under test, and then slowly let
go of the trigger, until the clamp head closed completely, please be sure to
test whether the conductor is picking up in the middle of the tong head, not
in the tong head center will produce additional error, clamp table can only
measure electrical conductor, a conductor if two or more current is measured
at the same time, the measuring reading will be wrong. 6) the Auto mode of AC
current need bigger than 0.8A, if the AC current is smaller, need change to
manual test mode 4.8 DC Current measurement
Warning An electric shock hazard. In current clamp measurements before the
test probe is removed from the instrument. 1Hold the trigger and test lead the
clampA wire line is measured clip in the meter. 2Read the current value in the
LCD display Noted: 3The correct measurement results cannot be obtained by
clamping two or more wires of the circuit under test at the same time. 4To
test two or more than two wires in same time, that cannot get correct resolute
5In order to obtain accurate readings, the conductor
15
Catalogue 1. Safety information 1.1 Preparation 1.2 Use 1.3 Mark 1.4 Maintenance 2. Description 2.1 Instructions 2.2 Button and Jacket 2.3 LCD display 3. Specifications 3.1 Overview 3.2 Technical indicators 4.O perations Guide 4.1 Data keep 4.2 Torch 4.3 Auto power off 4.4 Measurement 4.5 NCV 4.6 Live fire test 4.7 AC Current measurement 4.8 DC Current measurement 4.9 Voltage measurement 4.10 Resistant Measurement 4.11 Diode Measurement 4.12 Frequency Measurement 4.13 Temperature Measurement 5. Maintenance 5.1 Replace the battery 5.2 Replace the test leads 6. Accessories
……………01 ……………01 ……………02 ……………03 ……………03 ……………04 ……………04 ……………04 ……………06 ……………08 ……………08 ……………09 ……………12 ……………12 ……………12 ……………12 ……………13 ……………13 ……………14 ……………14 ……………15 ……………16 ……………17 ……………18 ……………18 ……………19 ……………19 ……………19 ……………20 ……………20
3. Specifications The instrument shall specify one yearduring 18¥ j 28¥
aThe relative humidity is less than 75% under the conditions of re
calibration. 3.1 Overview
Automatic measurement and manual measurement Overload protection The maximum
voltage allowed between the measuring terminal and earth600V DC or 600V AC
DisplayLCD Maximum5999 display Polar indicationAutomatic indicator-‘,Display negative Over range display
0L’ or `-0L’b Sampling time: about 3 times / sec
Display unit and power display Automatic power off15Minutes Open Jaw is 26mm;
test Line OD less than23mm Input static Current: less than 85mA Battery
type1.5V AAA*3 Battery voltage indicationLCD Symbol Temperature
coefficientless 0.1 operating temperature18¥ j 28¥ Storage temperature-10¥ j
50¥ Size184.0×66.0×34.8mm Weightabout 220gcIncluding battery 3.2 Technical
indicators Environment temperature23±5¥ Relative humidity<75%
08
under test should be placed as far as possible in the center
of the current clamp. 4″ ” Represents the maximum input ac current of 600 A. 6Please hold the clamp head when the current measure
ment machine to open the clamp head and nose pliers head
clip conductor under test, and then slowly let go of the
trigger, until the clamp head is closed completely, please be
sure to test whether the conductor is picking up in the
middle of the tong head, not in the tong head center will
produce additional errors, clamp table can only measure
electrical conductor, a conductor if two or more current is
measured at the same time, the measuring reading will be
wrong.
- the Auto mode of AC current needs bigger than 0.8A, if the
AC current is smaller, needs change to manual test mode
4.9 Voltage measurement
Warning
An electric shock hazard.
When the measurement of high voltage, please pay
special attention to avoid electric shock
Do not enter the effective value of voltage higher than
AC600V
1)Press the button longer than 2 seconds. At this time, the
meter is in Auto voltage measurement;
- Use black test lead inserted into the COM socket, the red
test lead is inserted into the
socket,
- Test lead will link the voltage source and load to test 4Read the voltage value on the LCD
16
1. afety Instructions This instrument strictly follow GB/T 13978-92 Generic
specification for Digital Clamp meter, Following GB4793.1-1995 cIEC-61010-1,
IEC-61010-2-032Electronic measuring instruments safety requirementsBelong to
the two class of pollutionVoltage standard CAT III 300V and CAT II 600V
This model is a 3 5/6 Smart digital clamp meter. It can be used to measure AC
and DC voltage, DC current, resistance, capacitance, frequency, temperature,
diode and on-off test, fire live test, NCV function with function symbol, data
holding, auto power off and backlight lighting functions. The instrument has
compact structure, safety jacket, which is easy to operate and easy to carry.
It is an ideal tool for electrical measurement.
Please follow the safety instructions, ensure the safety of the use of the
instrument. use and protect the item in right condition, the instrument will
be in satisfactory service. 1.1 Preparation 1.1.1 user must comply with the
standards of safety rules
when use it – Protection against electric shock – To prevent the misuse of the
instrument 1.1.2 After receiving instrument, check whether the damage in
transit. 1.1.3 Check and confirm the meter whether damaged or not after
shipment,
01
3.2.1 AC Current
Range 60A 600A
Resolution 0.01A 0.1A
Accuracy 2.5% + 8
3.0% + 10
-Input Min Current: 0.8mA AC
– Input Max Current: 600A AC – Frequency50Hz -60Hz
– When AC current is measured, the meter automatically opens
an internal low-pass filter to filter out high-frequency current.
3.2.2 DC current:
Range 60A 600A
Resolution 0.01A 0.1A
Accuracy c2.5% + 5 c3.0% + 8
3.2.3 DC voltage
Range 600mV 6V
Resolution 0.1mV 0.001V
Accuracy 0.8% + 5 0.5% + 3
60V 600V
0.01V 0.1V
1.0% + 5
– Input Min voltage0.6V AC -Maximum/ input voltage600V AC cEffective valueOR
600V DC – Frequency40Hz -1000Hz
09
notice: 1when the measured signal is greater than or equal to 0.61v, the meter
will display the dc voltage of course measured; When the measured signal is
less than 0.61v, the meter will default to the resistance value and display
the internal resistance value of the measured signal. 2″ “show the maximum
input voltage is 600V AC or 600V DC. 3 If the instrument measures more than
600V AC, issued an alarm 4) Also can select auto and manual test mode manually
4.10 Resistance test
Warning The risk of electric shock In the measurement of impedance on the
line, should be determined to disconnect the power supply circuit, capacitor
circuit completely discharge. 1)Press the button longer than 2 second. At this
time, the meter is in Auto voltage measurement; 2) Use black test lead is
inserted into the COM socket, the red test lead is inserted into the socket,
3) Test lead will link the voltage source and load to test 4
In the measurement of low resistance, in order to measure accurately, please
short-circuit the two test leads, otherwise if the test short-circuit is
bigger than 0.61V, the meter will think that is Voltage test mode Notice: 1
if measured resistance value is bigger than 60M, the LCD
17
1.1.4 Test leads must be in good condition. Check the insulation test is
damaged, the wire conductor is bare before use,
1.1.5 Use the test leads to ensure safety; they must bereplaced with the same
or similar rank test if necessary.
1.2 Use 1.2.1 Use the correct function and range. 1.2.2 Do not exceed the
scope of protection of the range of
the indicating value measurement. Do not exceed the scope of protection of the
range of the indicating value measurement 1.2.3 When measuring circuit, do not
touch the test lead tip (metal parts). 1.2.4 In the measurement, if the
measured voltage is higher than 60V DC or 30V AC (RMS), attention should be
paid to keep your fingers always after the test finger protection device.
1.2.5 If the voltage between the measuring end and the earth is more than AC
600V, don’t measure the voltage. 1.2.6 Before turning the switch changes the
measurement function, should be removed test lead from the circuit 1.2.7Don’t
live line measurement of resistance, diode and continuity test 1.2.8Under the
test ranges of current, resistance, diode and continuity test, it should be
taken to avoid the instrument connected voltage source. 1.2.9 Do not use this
instrument in the gas, steam or dust 1.2.10If you notice any abnormal or
faulty instruments,
02
3.2.4 AC voltage
Range 600mV 6V
Resolution 0.1mV 0.001V
Accuracy 1.0% + 8 0.8% + 5
60V
0.01V
600V
0.1V
1.2% + 5
– Input Min voltage0.6V AC
-Maximum/ input voltage600V AC cEffective valueOR
600V DC – Frequency40Hz -1000Hz
3.2.5 Frequency
Range 99.99Hz
Resolution 0.01Hz
Accuracy 0.5% + 2
999.9Hz
0.1Hz
9.999kHz
0.001kHz
99.99KHZ
0.01kHZ
999.9KHZ
0.1kHZ
Overload protection250V DC or ACcEffective value – Input range 200mV~10VPPcEffective valueWith the
increase of the measured frequency, the input voltage should be increased
3.2.6 Capacitance
Range 60nF
Resolution 0.01nF
Accuracy ±(3.0% of reading +5words
600nF
0.1nF
6uF
0.001uF
60mF
0.01mF
±(3.0% of reading +5words)
600mF
0.1m F
10
will display “OL”over range status 2
If the measured resistance value is less than 50, the meter will buzz alarm 3
If the measured resistance value is less than 1M, the instrument may take a
few seconds to stable reading, it is normal for high resistivity readings 4
When testing the on line resistant, please discharge the capacitate and all
power shut off to make sure the test value correct. 4.11 capacitance test
Warning Risk of electric shock. To avoid damage to the meter or the device
discharged capacitance before measuring 1) Press button switch to capacitance
test status 2) Black test lead is inserted into the COM socket, the red test
lead is inserted into the socket 3) Discharge the capacitance and link the
capacitance to test 4) Display readings on LCD Notice: 1
In order to improve the less than 10 nF test accuracy, should be minus the
meter and line capacitance. 4.12 Frequency test
Warning Risk of electric shock. To avoid damage to the meter or the device
under test, all power to the circuit under test should be cut off and all high
voltage capacitors fully discharged before measuring
18
should stop using 1.2.11 unless the instrument bottom shell and the battery
cover is fastened in situ; it should not use the instrument. 1.2.12 Do not
store or use the instrument in direct sunlight,
high temperature, high humidity conditions. 1.3 Mark
Note (safety information,is important see instructions Can be used for
dangerous live conductor Double insulation protectioncII CAT III In accordance
with theIEC-61010-1Over voltage standard level (installation) IIIaThe
pollution degree of 2 refers to the pulse voltage protection levels. In line
with European standards (EU) Grounding 1.4 Maintenance 1.4.1 Please do not
attempt to test lead the shell to adjust or repair instrument, this operation
can only be fully understood by technicians 1.4.2 Before test leading the
instrument bottom shell and the battery cover should be removed the test lead
from the measured line test lead 1.4.3 TO avoid false readings may cause
electric shock, when the instrument display ” ” symbol The battery should be
replaced immediately. 1.4.4 Use a damp cloth and a mild detergent to clean the
instrument; do not use abrasive detergents or solvents. 1.4.5 The instrument
when not in use should turn off the power,
03
6mF
0.001mF
±(5.0% of reading +5words
60mF
0.01mF
100mF
0.1mF
Not calibrated
3.2.7 Temperature test
Range
Accuracy
Resolution
20300
±(2.5%+5d)
1
3011000
±(2.5%+5d)
1
-4600
±(2.5%+5d)
1
6011832
±(2.5%+5d)
1
– Overload protection: 250V DC or AC (rms)
3.2.8 Resistance
Range
Resolution
Accuracy
600
0.1
±(1.2% + 2)
6k
0.001k
60k
0.01k
600k 6M
0.1k 0.001M
±(2.0% + 5
60M
0.01M
– open-circuit voltageAbout 0.4V
– Overload protection600V DC or ACcEffective value
3.2.9 Continuity test
Range
Resolution
Function
If the measured line
0. 1
resistance is less than 50, enclosing the instrument
may sound a buzzer
– Overload protection600V DC or ACcEffective value
11
the resistance.
-
Press button switch to frequency status
-
Black test lead is inserted into the COM socket, the red test
lead is inserted into the
socket
-
Test lead will link the voltage source and load to test
-
Display readings on LCD
The test range is 10HZ-10MHz, if test frequency is less than
10Hz, the display show “00.00” ,if larger than , When using this
function, don’t insert test leads
4.13 Temperature Measurement
Warning
Do not enter a temperature higher than 60V AC voltage
30V AC voltage to avoid damage or instrument damage
-
Press button switch to temperature status
-
Black test lead is inserted into the COM socket, the red test
lead is inserted into the
socket
- The other end of the K-type thermocouple (test side) close to
the surface of the measured object.
- To be read by the liquid crystal display to read the measured
temperature value.
Note:
K-type thermocouple distribution of the highest measurement
temperature of 250
5. Maintenance
5.1 Replace the battery
Warning
Before opening the instrument of the battery cover, please
removed the test leads from measuring circuit so that to
19
1.4.6 If you do not use a meter-long time, the battery should be removed to
prevent damage to the instrument.
2. Description – The instrument is a professional measuring instrument
with liquid crystal display and a back light source. The user readings easily.
Single hand operation with overload protection and low battery indicator. For
professional, factory, school, lovers or family use, is an ideal Multi-
function instrument. – Used for AC DC voltageaAC current, frequency,
resistance, capacitance measurement and the on-off circuit, measurement,
temperature measurement . – Automatic range – Data keep – Auto power off –
Relative measurement 2. Part name Ò Current clamp head: For current
measurement Ó The torch of head lamp Ô Panel Õ LCD Monitor Ö Power button ×
Common socket Ø Resistor, voltage Diode and Continuity, fire live, frequency,
capacitance, temperature test input jack (8Data hold and Torch (9) Select
function change between Resistor, voltage Diode and Continuity (10) Alarm
light: Continuity NCV and High voltage alarm
04
3.2.10 Diode test
Range
Resolution
Function
1mV
Show the approximate diode
forward voltage value – Overload protection600V DC or ACcEffective value
4. Operations Guide
4.1 Data keep
In the process of measurement, such as the need to keep reading, push keyThe display value will be locked, then press the button so that relieve readingb
4.2 Torch
- Press long than 3 second, then open the torch. Press
again then close the torch. Torch cannot close automatically
need close manually.
- Torch is LED, long time on will decrease the battery life,
please use the torch for short time and close the torch in time. If the battery and voltage are not enoughcabout3.6V
The LCD display” “symbol, at this time , if you use Torch ,
the current is big so you should not replace the battery. If you
do not use the Torch , the LCD show ” “, you should replace
the battery.
4.3 Automatic power off 1Without operation after 15 minutes The meter will
enter the sleep state automatically shut down to save power.
1 minute before the shutdown, each 1 minutes the buzzer 1
sound prompt, dormant into a long sound after that before
the shutdown.
4.4 Measurement
12
avoid the risk of electric shock. 1) if ” “symbol displayplease replace the batteryb
- Unscrew fastening screws of the battery cover and move
away.
- replace the old battery
notice:
The battery polarity cannot be reversed
5.2 Change Test Leads
Warning
Please use the same test leads or same level test
leads
if you need replace to the test leads . the test leads
level: 1000V 10A.
If one damaged insulation, such as wire exposed, must be
replaced.
6. Accessories
1Test lead
level1000V 10A
one
2Manual
one
3battery
1.5V AAA
two
The contents of this manual are subject to change without
notice
The contents of this brochure are believed to be correct, if
users find errors, please contact the manufacturer. The company is not responsible for the accident and harm
caused by user wrong operation * This manual describes the function, not for other special use
20
(11) NCV light
05
1Toggle the switch and open power, If the battery and voltage Is not
enoughcabout2.4V The LCD display” “symbol then the battery should be replaced
2” “symbolThe input voltage or current should not exceed the value indicated,
this is to protect the internal circuit from being damaged.
3Connect the public test line, and then connected test line is When in wiring,
The test should be removed first line charged dismantling wiring.
4) when power is on, the meter has not entered to test mode, will enter to
scan mode, then can press enter to related test mode
5) At any test mode, Press enter to auto testing mode 4.5 NCV (Non-contact
voltage test) Press button, When clamp head close to mains phase line or power
switch, socket the detected voltage is close to the 110V AC RMS
the indicator will change from green to green +yellow When the induction
voltage is higherthe indicator will change to green +yellow+ red ,With buzzer
alarm more intensive and indicator will shine high frequency
Warning Even if no indication but the voltage may still exist. Don’t rely on
non-contact voltage detector to determine whether there is a voltage shielded
wire. The operation may affect the detection by socket design, insulation
thickness and different types
13
Warranty Please show your product certification when you need repair service
or something wrong with items, it is effective show one and purchase invoice
in together 1Please contact with our company or repair service department when
your clamp meter appears faults as soon as possible, don’t delay your use and
warranty period. 2Our company provides warranty service for one year from the
date of purchasebThe company provides free warranty service after professional
confirms the problem is not by user sabotage during the warranty period
3Repair need charges (repairs components fee) more than the warranty period
4All of the following will charge the cost of repair even in the warranty
period. ÒImproper use or accidental disasters caused damage of components and
circuit board burn ÓNon-professional personnel open shell, check and
modification ÔDo not follow the instructions to operation caused problems ÕNo
maintenance and repair of the other company products Öusers offer the
maintenance of postage and transportation fees ×Clamp meter’s battery, probe,
temperature probe and other functional accessories not included free warranty
list
21
2.3 LCD display
06
4.6 Firing live Measurement
-
Press button and enter Live mode ,LCD display”Live”.
-
The red test leads into the
jack.
the other hand on test circle.
- If the red lead is a fire line, the indicator will change to green
+yellow+ red, With buzzer alarm more intensive and indicator
will shine high frequency
if there is no these single, the line is null line Note 1The Voltage Test range of AC 110V~380V)
- Please strictly observe the safety rules and standards for
this range of test
4.7 AC Current measurement
Warning
An electric shock hazard.
In current clamp measurements before the test probe is
removed from the instrument. 1
Hold the trigger and test lead the clampA wire line is
measured clip in the meter.
2
Read the current value in the LCD display
Noted 1
The correct measurement results cannot be obtained by
clamping two or more wires of the circuit under test at the
same time. 2
To test two or more than two wires in same time, that
cannot get correct resolute
3In order to obtain accurate readings, the conductor
under test should be placed as far as possible in the center
14
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>