VEVOR AT1-2200X Single Phase VFD Drive Inverter User Manual

June 1, 2024
VEVOR

VEVOR-logo

VEVOR AT1-2200X Single Phase VFD Drive Inverter

Specifications:

  • Model: AT1-2200X
  • Type: Inverter
  • Input Voltage: Single phase AC 220V
  • Output Voltage: Three phase 220V AC
  • Power Output: 15V, 5V
  • Analog Voltage Input: 0-5/10V
  • Relay Output: C – 250VAC 5A/30VDC 3A, B – Normal Close, A – Normal Open

Product Usage Instructions

  1. Installation and Wiring:
    Before starting, make sure to read the entire user manual carefully.

Main Circuit Terminal and Function Description:

  • L,N: Single-phase AC input terminal
  • U,V,W GND: Output terminal to connect to Three-phase 220V AC motor, Grounding terminal

Terminal Description:
Port: Functional Description – Instructions

  • X6: Input port 6 (Reversing switch) – Short  Port X6 and COM for effective input signal
  • X5: Input port 5 (Reverse rotation Control switch) – Short Port X5 and COM for effective input signal
  • X4: Input port 4 (Forward rotation Control switch) – Short Port X4 and COM for effective input signal
  • X3: Input port 3 (section speed 3) – Short Port X3 and COM for effective input signal
  • X2: Input port 2 (section speed 2) – Short Port X2 and COM for effective input signal
  • X1: Input port 1 (section speed 1) – Short  Port X1 and COM for effective input signal
  • COM: Common GND
  • VL1: External analog voltage input – 0-5/10V Analog voltage input
  • SP1: Open-collector output 1
  • 5V: Power output supply – 5V, 20mA power output
  • TC: Relay output C – 250VAC 5A/30VDC 3A
  • TB: Relay output B – Normal Close
  • TA: Relay output A – Normal Open

Multi-speed Input Frequency Control Table:

Section| Section speed input 1| Section speed input 2| Section speed input 3| Frequency
---|---|---|---|---
Main Speed| 1| 1| 1| 50
Section speed 1| 0| 1| 1| 45
Section speed 2| 1| 0| 1| 40

Frequently Asked Questions (FAQ):

  1. Q: Where can I find technical support or request an e-warranty certificate?
    A: You can visit our website at www.vevor.com/support for technical support and e-warranty certificate requests.

  2. Q: What should I do with the product for correct disposal?
    A: This product requires separate refuse collection in the European Union. Please take it to a collection point for recycling electrical and electronic devices.

  3. Q: How can I verify if I am actually saving half in comparison with top major brands?
    A: The expressions like “Save Half” represent an estimate of savings compared to major top brands. We recommend carefully comparing the prices and features before making a purchase to ensure the savings benefit you.

Technical Support and E-Warranty Certificate www.vevor.com/support
Inverter
MODEL: AT1-2200X

  • We continue to be committed to provide you tools with competitive price.
  • “Save Half”, “Half Price” or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and does not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are actually saving half in comparison with

MODEL:AT1-2200X

NEED HELP? CONTACT US!

  • Have product questions? Need technical support? Please feel free to contact us:
  • Technical Support and E-Warranty Certificate
  •  www.vevor.com/support the top major brands.

This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

IMPORTANT SAFEGUARDS

  • Read all safety warnings, instructions, illustrations and specifications provided with this inverter. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury.
  • WARNING :
    This equipment is a high voltage device, please do not attempt to disassemble this equipment at any time to avoid danger. After a device failure, if the external switch fails to restart the device, please contact your reseller for handling.

WARNING: ELECTRICAL SHOCK AND FIRE HAZARD!

  1. Failure to comply with this instruction could result in an electrical failure, fire and electrocution.
  2. DO NOT DISASSEMBLE .
  3. Do not submerge inverter .
  4. Do not connect two or more transformers in parallel
  5. Plug the power supply unit directly into a GFCI wet location outlet .
  6. Do not use an extension cord
  7. Installation of this inverter and related wiring must be done by qualified electrician in compliance with all applicable electrical codes.

WARNING :
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment .
SAVE THESE INSTRUCTIONS

FCC Information

CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment!
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This product may cause harmful interference.
  2. This product must accept any interference received, including interference that may cause undesired operation.

WARNING: Changes or modifications to this product not expressly approved by the party. responsible for compliance could void the user’s authority to operate the product.
Note: This product has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules, These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This product generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

  • If this product does cause harmful interference to radio or television reception, which can be determined by turning the product off and on, the user is encouraged to try to correct the interference by one or more of the following measures.
    • Reorient or relocate the receiving antenna.
    • Increase the distance between the product and receiver.
    • Connect the product to an outlet on a circuit different from that to which the receiver is connected.
    • Consult the dealer or an experienced radio/TV technician for assistance.

Correct Disposal

This product is subject to the provision of European Directive 2012/19/EC. The symbol showing a wheelie bin crossed through indicates that the product requires separate refuse collection in the European Union. This applies to the product and all accessories marked with this symbol. Products marked as such may not be discarded with normal domestic waste, but must be taken to a collection point for recycling electrical and electronic devices.

Installation and wiring

  1. Main circuit terminal and function description (1) Single-phase to three-phaseVEVOR-AT1-2200X-Single-Phase-VFD-Drive-Inverter- \(3\)
Terminal label Function description
L,N Single phase AC 220V input terminal
U,V,W Output terminal connect to Three phase 220V AC motor
GND Grounding terminal

 Terminal description

Port Function description Instructions
15V 15V power output 200mA15V output
X6 Input port6 (Reversing switch) Short Port X6 and COM, input signal

effective
X5| Input port 5(Reverse rotation Control switch)| Short Port X5 and COM, input signal effective
X4| Input port 4(Forward rotation Control switch)| Short Port X4 and COM, input signal effective
X3| Input port 3(section- speed 3)| Short Port X3 and COM, input signal effective
X2| Input port 2(section- speed 2)| Short Port X2 and COM, input signal effective
X1| Input port 1(section- speed 1)| Short Port X1 and COM, input signal effective
COM| Common GND|
VL1| External analog voltage input| 0-5/10 V Analog voltage input
SP1| Open-collector output 1|
5V| 5V power output| supply 5V 20mA power output
TC| Relay output C|

  • 250VAC 5A/30VDC 3A
  • TA and TB Normal Close ,TA and TC Normal Open

TB| Relay output B
TA| Relay output A

 Multi-speed input Frequency control table

| Section speed input 1| Section speed input 2| Section speed input 3| Original Frequency
---|---|---|---|---
Main Speed| 1| 1| 1| 50
Section speed 1| 0| 1| 1| 45
Section speed 2| 1| 0| 1| 40
Section speed 3| 0| 0| 1| 35
Section speed 4| 1| 1| 0| 30
Section speed 5| 0| 1| 0| 25
Section speed 6| 1| 0| 0| 20
Section speed 7| 0| 0| 0| 15
Note:| 0 means input Port connect with COM, 1 means disconnect.

Basic operation wiring diagram

  1. Single-phase input three-phase output
    ( Three phase 220V, if 380V Star-connection method needs to change to the 220V Delta-connection method)VEVOR-AT1-2200X-Single-Phase-VFD-Drive-Inverter-
\(4\) VEVOR-AT1-2200X-Single-Phase-VFD-Drive-
Inverter- \(5\)

 Operation panel

 Keys instructions

| Icon| Function description
---|---|---
1| (Programming)| For selecting mode or Programming mode (it is available not mater the Inverter star or stop), press this key for modifying parameters.
2| (Function/ Save)| Function data setting key. Normal mode: press this key to display the information of the Inverter, such as target frequency, output frequency and current, temperature;
3| Key ****| Parameter number or parameter value increase| Short press this key, then the numerical value will change gradually. Long press this key, then the numerical value will change rapidly
4| Key

| Parameter number or parameter value decrease
5| Shift| Shift in programming mode, jog in normal mode
6| Forward/ Reverse| Forward/ Reverse switching key
7| Start| Start Inverter output
8| Stop / Reset| Break down, fault resetting
Note| Please modify the parameters under the stop state, otherwise the changed parameters cannot be saved.

Chapter 2 Parameter specification

Parameter specification

Parameter Parameter specification Parameter range Default Unit
P00 Maximum voltage 0—220.0/380.0 220/380 V
P01 Reference frequency 0—400.0 50 Hz
P02 Intermediate voltage 0—220.0/380.0 110/190 V
P03 Intermediate frequency 0—400.0 25 Hz
P04 Minimum voltage 0—220.0/380.0 0 V
P05 Minimum frequency 0—400.0 0 Hz
P06 Maximum operating 0—400.0 65.0 Hz
P07 Minimum operating 0—400.0 0 Hz
P08 Hide password 0—65535 00000
P09 Input password 0—65535 0
P10 Working frequency source 0: Panel keyboard; 1:Panel potentiometer;
2:External analog signal 4: RS485. ****

1

|


P11

| Start/stop control source|

  • 0: Panel keyboard;
  • 1: RS485;
  • 2: External port.

| ****

0

|
P12| Stopping Modes|

  • 0:Inertial stop;
  • 1:Deceleration stop;

| 1|
| | 2: Brake stop; 3:Emergency brake.| |
---|---|---|---|---
P13| Braking time| 0—2.5| 0.5| S
P14| Braked Voltage| 0—140.0| 20| V
P17|  Machine number| 1-255| 1|
P18| Operating arrival| 0—100.0| 50| Hz
P20| Over temperature protection selection| 1—80| 80|
P21| Revolution     for 50Hz| 0-8000| 2800|
P22| Carrier setting| 1—20| 10|
P23| Frequency adjusting    step size| 1—100| 5| 0.1H z
 P24| Overload protection buffer time| 0.1—60.0| 3| S
P26| Working frequency| 0—400.0| 50| Hz
P27| Section speed 1 setting| 0—400.0| 45| Hz
P28| Section speed 2 setting| 0—400.0| 40| Hz
P29| Section speed 3 setting| 0—400.0| 35| Hz
P30| Section speed 4 setting| 0—400.0| 30| Hz
P31| Section speed 5 setting| 0—400.0| 25| Hz
---|---|---|---|---
P32| Section speed 6 setting| 0—400.0| 20| Hz
P33| Section speed 7 setting| 0—400.0| 15| Hz
P34| Main rising velocity| 1—1000| 25| Hz/S
P35| 1st rising velocity| 1—1000| 25| Hz/S
P36|  2nd rising velocity| 1—1000| 25| Hz/S
P37| 3rd rising velocity| 1—1000| 25| Hz/S
P38| 4th rising velocity| 1—1000| 25| Hz/S
P39| 5th rising velocity| 1—1000| 25| Hz/S
P40| 6th rising velocity| 1—1000| 25| Hz/S
P41| 7th rising velocity| 1—1000| 25| Hz/S
P42| Main descent velocity| 1—1000| 25| Hz/S
P43| 1st descent velocity| 1—1000| 25| Hz/S
P44| 2nd descent velocity| 1—1000| 25| ****

Hz/S

P45| 3rd descent velocity| 1—1000| 25| ****

Hz/S

P46| 4th descent velocity| 1—1000| 25| Hz/S
P47| 5th descent| 1—1000| 25| Hz/S
| velocity| | |
---|---|---|---|---
P48| 6th descent velocity| 1—1000| 25| ****

Hz/S

P49| 7th descent velocity| 1—1000| 25| Hz/S
**** P50| Multi function input 1 (X1 binding post)|

  • 0:invalid,terminal is non-functioning 1:wire control stop 2:keying stop; 3:keying operation; 4:stop keying;
  • 5:wire forward operation 6:wire reverse operation;
  • 7: reservation
  • 8: error reset signal;
  • 9: wire reversing switch; 10:keying forward switching;
  • 11:keying forward switching;
  • 12: reverse switch keying;
  • 13: section speed input 1;
  • 14:section speed input 2;
  • 15: section speed input 3;
  • 16: external error signal.
  • 17: Jog Forward;
  • 18: Jog Reverse;

| 13|
P51| Multi function input 2| 14|
P| Multi function input 3| 15|
P53| Multi function input 4| 5|
P54| Multi function input 5| 6|
****
P55| **** Multi function input 6| 9|
| | 19: Emergency stop; 20:Relay Control.| |
---|---|---|---|---
**** P58| Multi function input 1     (SP1)|

  • 0: invalid, no output; 1:operating instructions; 2:set arrival instructions 3: fault indication;
  • 5: Emergency stop;
  • 6: For P50—P55=20;

| 0|


P60

| Multi function input 2| Idem (Relay output)| 0|
P62| Display options|

  • 0: setting frequency;
  • 1: operating frequency;
  • 2: revolution 3: current;
  • 4: temperature; 5: time;

| ****

0

|
P65| Power on options|

  • 0: normal power on;
  • 1: report error with start signal
  • 2:Power on forward;
  • 3:Power on reverse.

| ****

0

|
P66| Input stabilization time| 0—65535| 60| mS
P67| Voltage coefficient| 0—65535| 28500|


P68

| Under voltage

setting

| ****

0—220/380

| 60/180| V
P69| Overvoltage setting| 220.0—400/680| 400/600| V
P70| Torque compensation options| 0: P72 is compensation amount; 1: Multiply P72 by P71 after P71 minus input voltage| ****


0

|


P71

| Torque compensation voltage| 0—300.0| 10| V
---|---|---|---|---
P72|  Torque compensation setting| 0—100| 0|
P73| Maximum external analog| 0—65535| 31440|
P74| Minimum external analog| ****

0—65535

| 2096|
P75| Zero current compensation value| 0—65535| 1130|
P76| Current coefficient| 0—65535| 28000|
P77| Parameter reset| 0—65535 (It is the reset when 54321)|

0

|
P78| Main current overload| 0-65535| 12000| mA
P79| First current overload| 0-65535| 12000| mA
P80| Second current overload| 0-65535| 12000| mA
P81| Third current overload| 0-65535| 12000| mA
P82| Fourth current overload| 0-65535| 12000| mA
P83| Fifth current overload| 0-65535| 12000| mA
P84| Sixth current| 0-65535| 12000| mA
| overload| | |
---|---|---|---|---
P85| Seventh current overload| 0-65535| 12000| mA
P86| Jog forward frequency| 0—400.0| 20| Hz
P87| Jog reverse frequency| 0—400.0| 20| Hz
P88| Jog rising velocity| 1—1000| 50| Hz/S
P89| Jog descent velocity| 1—1000| 50| Hz/S
**** P90| Jog stopping modes|

  • 0:Inertia stop; 1:Decelerate stop; 2:Braking stop;
  • 3:Emergency brake.

| 1|
P91| Jog braking time| 0—2.5| 0.1| S
P124| Fan start temperature| =0 Fan running when VFD starts| 0| ℃
P127| Remaining hours| 0—65535| 65535| H

Parameter setting password and Down time stop:

  • P08 is the hidden password, it always shows only 00000, not the actual value.
  • When input the value of P09=the hidden value of P08, the P08 shows hidden value, and the P08 and other parameters can be changed. The P09 will be nullified when unplug the power cable to restart.
  • When P127=65535,the function of countdown do not start.
  • When P127 < 65535,the function of countdown will start, the P127 will minus 1 when the Inverter runs for one hour. The frequency converter will be stopped when the countdown of P127 to 0 hour.

Parameter setting procedure:

  1. Press the programming key to enter into the programming state;
  2. Use the arrow keys and shift key to find the parameters that need to be modified;
  3. Press function/save key to enter into the parameter;
  4. Use the arrow keys and shift key to amend the parameter value;
  5. Press the function/ save key to store the parameter;
  6. Press the programming key to exit the programming state.

 Fault Code

Fault Code Display Fault Code Description
Err 1 Short Circuit/Current overload/Power Module protection
Err 2 Undervoltage protection
Err 3 Over voltage protection
--- ---
Err 4 Driving Circuit Failures
Err 5 Input at startup when electrified
Err 6 Over current protection
Err 7 Overtime
Err 8 Excessive temperatures for radiator
Err 9 External fault

Made In China

References

Read User Manual Online (PDF format)

Loading......