Introduction

It is intended to record and store electrocardiogram (ECG) rhythms, and transfer records to the software for further research or analysis.
It is not a medical device and should not be used for any medical purposes or any medical conditions. It is intended only for general wellness use.

Warnings

  • The ECG results (including the regular heartbeat) do not guarantee that you are free from arrhythmia or other health conditions. You should notify your physician of possible changes in your health.
  • Do not use the device to self-diagnose heart-related conditions. Consult with your physician before making any medical decisions, such as altering your use of any drug or treatment.
  • Do not continue to use the device until further instructed by a physician if your skin is irritated or inflamed around the electrodes.
  • The device makes no warranty for any erroneously collected data or information from misuse or malfunction as a result of abuse, accidents, alteration, negligence, or failure to maintain the products as instructed. The results made by this device are preliminary screening of cardiac conditions, not a complete diagnosis. All interpretations should be reviewed by a medical professional for clinical decision-making.
  • The device has not been tested for and is not intended for pediatric use.
  • Keep the device away from young children. Contents may be harmful if swallowed.
  • Do not store in extremely hot, cold, humid, wet, or bright conditions.
  • Do not take a recording if the electrodes are dirty. Clean them first.
  • Do not immerse the device in or expose the device to excessive liquid.
  • Do not drop or bump with excessive force.
  • Do not expose to strong electromagnetic fields.
  • Do not expose the device to a magnetic resonance (MR) environment.
  • Do not use a cardiac pacemaker, ICDs, or other implanted electronic devices.
  • Do not use it during cautery and external defibrillation procedures.
  • Do not place the electrodes in contact with other conductive parts including the earth.
  • Do not use unapproved accessories. The use of unapproved accessories or transducers and cables may result in electromagnetic emission or decreased electromagnetic immunity of this device which will further lead to improper operation.
  • Do not use the device adjacent to or stacked with other equipment because it may result in improper operation.

Packing List

  • Main unit
  • A USB clip
  • A USB drive with the software
  • A pack of disposable electrodes (10 pieces)
  • Chest strap

Guide to Parts

LiVENPaCE Personal ECG Tracker - Guide to Parts

Indicator Status Description
/ OFF Out of battery
Greenlight On with high brightness Fully charged
Orange light Charging
Greenlight /Orange light (low battery) Flashing every 5 seconds with medium
brightness In standby mode
Flashing with medium brightness Downloading data
On with low brightness read off

On with low brightness and flashing with medium brightness when detecting R wave| Recording your ECG

Activate the Device

5.1. Charge the device
a) Connect the device with the USB clip, as shown below.LiVENPaCE Personal
ECG Tracker - Charge the device

b) Connect the other end of the clip to a power supply, like a laptop or power adapter.

Note:

  • The power adapter is not included in the package.
  • Compatible power adapter output: DC 5V, 1A.
  • Do not use the device while charging.

5.2. Download software and sync time
a) Download the software For macOS & Windows:
Visit the website www.livenpace.com/pages/download for free download.
For macOS:

  • Search for “Livenpace” in the App Store.
    For Windows:

  •  Find the accompanied USB drive and copy the installation file to your local drive for installation.

b) Install the software.
c) Connect the device to your PC or laptop with the power/data cable and run the software. It will automatically connect to the device and synchronize time.

Note:

  • Failed time synchronization may result in the wrong recording time.
  • For more information on how to use the software, visit the website https://livenpace.com/pages/support or scan the QR code below.

LiVENPaCE Personal ECG Tracker - qr codehttp://qr.hotlnk.cn/url/79838268235

Record your ECG

6.1. Wear the device
Choose one of the following methods for recording ECG:

With electrodes
a) Remove the body hair and moisturize the skin of the contact area.
b) Attach the device to the disposable electrodes.

c) Remove the protective film from the electrodes.
d) Apply the device to the left chest. The “R” symbol is rightward and near the middle of the sternal notch, and the other end is leftward and 45° lower than the horizontal level.

With chest strap
a) Attach the device to the chest strap.

b) Moisturize the skin with water or water-based lotion on the contact area.

c) Untie the strap and position the device across the front of the chest just below your pectoral (chest) muscles.

d) Adjust the strap so that it wraps around tightly yet comfortably.

6.2.Start recording
Once you wear the device properly, it starts acquiring ECG data.

6.3. Stop recording
The device will automatically stop recording and enter standby mode one minute after it is taken off.

Note:

  • The device can store 10 recordings, 30 hours in total. When the recordings exceed 10 pieces, or the total time reaches 30 hours, the earliest data will be covered with a new one.
  • One single recording can only store 24 hours of data at most.
  • Please download the data as soon as possible after the ECG recording is completed.

View ECG Measurement Results

Connect the device to your PC or laptop with the power/data cable and run the software. You can download ECG waveform and detail reports including overview, supraventricular rhythm, ventricular rhythm, HRV, ECG report conclusion, hourly statistics table of ECG data, and ECG Fragment.

Note:

  • The ECG waveform and report are saved in the default directory. If you change the storage directory, the previously stored recordings will not be seen in the task list.

Caution:

  • If you are experiencing any symptoms or have concerns, contact your physician.

Maintenance

No service or repair should be performed on the hardware other than the maintenance listed in this section.
It is important to keep the electrodes clean by spraying them with an alcohol- based sanitizer and wiping them with a soft cloth when needed.

  • Do use a clean, lint-free cloth
  • Do not use abrasive cleaners or materials
  • Do not immerse the device or expose device to excessive liquid

Exterior Visual Inspection:

  • Inspect electrodes for warping, surface damage, or corrosion
  • Check for any other forms of damages

Troubleshooting

If you experience difficulties in operating your device, refer to the troubleshooting guide below.

Problem:
My device is not working.| Solution
Option: Charge the device.
---|---
Problem:
I have a lot of artifacts, noise, or interference in my recordings.| Solution
Option 1: Replace the disposable electrodes.
Option 2: Moisten the electrode areas of the strap and adjust the strap length to fit tightly but comfortably.
Problem:
I cannot download the recordings.| Solution
Option 1: Charge the device.
Option 2: Try another operating system.

Specifications

Operating conditions
Temperature: 5 °C to 45 °C
Relative Humidity: 10% to 95 % (noncondensing)
Atmosphere pressure: 700 hPa to 1060 hPa

Storage / Transport conditions
Temperature: -25 °C to 60 °C
Relative Humidity: 10% to 95 % (noncondensing)
Atmosphere pressure: 700 hPa to 1060 hPa

Power and supply
Rechargeable lithium-polymer battery
Capacity: 90mAh
Charging time: 2 hours (to 90% power)

ECG
Lead type: Single-lead ECG
Input impendence: ≥10MΩ, 10Hz
Linearity and dynamic range: 10mV (peak-to-valley)
Common mode rejection: ≥60dB
Frequency response: 0.67 – 40 Hz
Gain error: Maximum error ±10%

Others
Dimension: 100×23×8.3 mm
Weight: <35 g (with battery)
IP classification: IP 22
Expected service life: 5 years

Symbols

Symbol Description
Indicates a medical device that is not to be disposed of as unsorted

municipal waste.
| Resistant to liquid ingress
****| This product complies with the rules and regulations of the Federal Communication Commission.
| Non-ionizing radiation

FCC Statement

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
    The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.

Shenzhen Livenpace Technology Co., Ltd.
402, Floor 4, BLD 9, Baiwangxin High-Te c h Industrial Park, Songbai Road, Nanshan
District, 518110, Shenzhen, Guangdong, P.R.
China

Product name: Personal ECG Tracker Model: HHM1
PN: 255-05295-00 Version: A Date: July 18, 2022

Documents / Resources

| LiVENPaCE Personal ECG Tracker [pdf] User Manual
0001, 2A728-0001, 2A7280001, Personal ECG Tracker, Personal Tracker, ECG Tracker, Tracker
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals