LIVENPACE DuoEK-S Personal ECG Monitor User Manual
- June 3, 2024
- Livenpace
Table of Contents
LIVENPACE Duo EK-S Personal ECG Monitor
Introduction
It is intended to record and store electrocardiogram (ECG) rhythms, and
transfer records to compatible mobile App for further research or analysis. It
is not a medical device and should not be used for any medical purposes or any
medical conditions. It is intended only for general wellness use.
Warnings
- The ECG results (including regular heartbeat) do not guarantee that you are free from an arrhythmia or other health conditions. You should notify your physician of possible changes of your health.
- Do not use the device to self-diagnose heart-related conditions. Consult with your physician before making any medical decision, such as altering your use of any drug or treatment.
- Do not continue to use the device until further instructed by a physician if your skin is irritated or inflamed around the electrodes.
- The device makes no warranty for any erroneously collected data or information from misuse or malfunction as a result of abuse, accidents, alteration, negligence, or failure to maintain the products as instructed. The results made by this device are preliminary screening of cardiac conditions, not a complete diagnosis. All interpretations should be reviewed by a medical professional for clinical decision-making.
- The device has not been tested for and is not intended for pediatric use.
- Keep the device away from young children. Contents may be harmful if swallowed.
- Do not take a recording while driving or during physical activity.
- Do not store in extremely hot, cold, humid, wet, or bright conditions.
- Do not take a recording if the electrodes are dirty. Clean them first.
- Do not immerse the device in or expose the device to excessive liquid.
- Do not drop or bump with excessive force.
- Do not expose to strong electromagnetic fields.
- Do not expose the device to a magnetic resonance (MR) environment.
- Do not use with a cardiac pacemaker, ICDs, or other implanted electronic devices.
- Do not use during cautery and external defibrillation procedures.
- Do not place the electrodes in contact with other conductive parts including the earth.
- Do not use with unapproved accessories. The use of unapproved accessories or transducers and cables may result in electromagnetic emissions or decreased electromagnetic immunity of this device and result in improper operation.
- Do not use the device adjacent to or stacked with other equipment because it may result in improper operation.
Packing List
- Main Unit
- USB Cable
Guide to Parts
Indicator | Status | Description |
---|---|---|
/ | OFF |
- Not activated
- Out of battery
Green light| Flashing with the rhythm of the heartbeat|
- Recording your ECG
---|---|---
Flashing every 5 seconds|
- Fully charged
- In standby mode
Orange light| On|
- Charging
Flashing every 5 seconds|
- Low Battery
Blue light| On|
- Connected to the App and ready to start recording
Flashing with the rhythm of the heartbeat|
- Connected to the App and recording your ECG
Using the Device
Charge and activate your device
Connect the device with power adapter by the charging cable. Note:
- The power adapter is not included in the package.
- Compatible power adapter output: DC 5V, 1A
- Do not use the device while charging.
Download Liven pace App
- a) Download the Liven pace App from iOS App Store or Google Play Store. Or you can scan the QR code below.
Note:
Be sure to use a compatible iOS or Android device.
- iOS: iOS 10.0 or above
- Android: Android 7.0 or above
- b) Make sure Bluetooth is turned on in Settings of your smartphone or tablet.
- c) Launch the Liven pace App and follow the instructions in the App to set up and pair your device.
Note:
For more information on how to use the software, visit the website
https://livenpace.com/pages/support or scan the QR code below.
Record your ECG
- a) Choose one of the following methods for recording ECG:
Lead I
Hold onto the device with both hands. Note: If the ECG quality is poor with
Lead I, please try to use Lead II. Lead II
Hold the right electrodes with the right hand, place the left electrodes on
the left leg. Chest Lead
Hold the right electrodes with the right hand, place the device on the chest
(below the pectoral muscles). Note:
- Please make sure that the “R” symbol is always on the right hand or chest.
- DO NOT use the electrodes on a portion of the body with too much body fat, body hair or very dry skin; otherwise, a successful recording may not be possible.
- b) Hold still for at least 30 seconds.
Note:
You can turn on/off the heartbeat sound of the device in the App.
- c) When the recording exceeds 5 minutes or the electrodes lose contact with your skin, the device will automatically stop recording with a long beep.
View ECG measurement results
Upon completion of your ECG recording, the device will display the measurement
results on the screen and the records will be synced to the App.
Result | Description |
---|---|
Regular heartbeat | No rhythm abnormalities were detected in your ECG. |
Irregular heartbeat | Some rhythm abnormalities were detected in your ECG. |
Poor signal | There is too much interference in this recording. |
Slow heart rate | Your heart rate is less than 50 beats per minute, which is |
slower than normal for most people.
---|---
Fast heart rate| Your heart rate exceeds 120 beats per minute. This can be
normal with stress or physical activity.
Caution:
If you are experiencing any symptoms or have concerns, contact your physician.
Note:
All historical results can be viewed, downloaded, and shared in the App.
Maintenance
No service or repair should be performed on the hardware other than the maintenance listed in this section. It is important to keep the electrodes clean by spraying with an alcohol-based sanitizer and wiping with a soft cloth when needed.
- Do use a clean, lint-free cloth
- Do not use abrasive cleaners or materials
- Do not immerse device or expose device to excessive liquid
Exterior Visual Inspection:
- Inspect electrodes for warping, surface damage, or corrosion
- Check for any other form of damage
Troubleshooting
If you experience difficulties in operating your device, refer to the
troubleshooting guide below.
Specifications
Operating conditions
- Temperature: 5 °C to 45 °C
- Relative Humidity: 15% to 95 % (non-condensing)
- Atmosphere pressure: 700 hPa to 1060 hPa
Storage / Transport conditions
- Temperature: -25 °C to 55 °C
- Relative Humidity: 15% to 95 % (non-condensing)
- Atmosphere pressure: 700 hPa to 1060 hPa
Power and supply
- Rechargeable lithium-polymer battery Capacity: 90mAh
- Rating: DC 5V, 5W
ECG and HR
- Heart rate range: 30 to 250 BPM
- ECG Measuring length: 30 seconds to 5 minutes
Others
- Dimension: 92×32×8.2 mm (main unit)
- Weight: 26.8g (main unit)
- Wireless connectivity: Bluetooth® 5.1
- Connector: USB Type C
- Internal memory: Up to 10 ECG recordings
- Applied part: Type CF (electrodes)
- IP classification: IP 22
Symbols
FCC Statement
FCC Warning:
FCC ID: 2A728-0003
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment. This
device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
References